arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2602.06379stat.MEstat.AP
收藏

适应性临床试验的E值:实践中任何时间有效的监控

E-values for Adaptive Clinical Trials: Anytime-Valid Monitoring in Practice

Knight Cancer Institute(克奈特癌症研究所);Oregon Health and Science University(俄勒冈健康与科学大学);Department of Systems Engineering and Operations Research(系统工程与运筹学系);George Mason University(乔治梅森大学)

Alexandra Sokolova, Vadim Sokolov

AI总结:

本文提出了一种基于e值的适应性临床试验监控方法,展示了其在控制I类错误和提升统计功效方面的有效性,并提供了与传统方法结合的指导。

摘要:

适应性临床试验依赖于中间分析、灵活停止和数据驱动的设计修改,这些都会在固定时间框架测试统计量被重复检查或在适应后重新使用时复杂化统计保证。E值和e过程提供了任何时间有效的测试和置信序列,它们在可选停止和可选继续的情况下仍然有效,而不需要预设的监控计划。本文为从业者提供了方法指南。我们开发了e过程的下注-martingale构造,用于双臂随机对照试验,展示了e值如何自然处理复合原假设并支持无效性监控,并提供了何时e值适用、何时已建立的替代方法更优以及如何将e值监控与组序列和贝叶斯自适应工作流结合的指导。数值研究比较了五种监控规则——频率主义、贝叶斯和e值方法的朴素和校准版本——在双臂二元终点试验中的表现。朴素重复检验和朴素后验阈值在频繁中间检查下显著增加I类错误。在有效的方法中,校准的组序列规则实现了最高的功效,e值规则提供了稳健的任何时间有效控制,但功效中等,而校准的贝叶斯规则是最保守的。扩展的模拟显示,组序列和e值方法之间的功效差距取决于监控计划,并在连续监控下逆转。该方法,包括无效性监控、平台试验多重性控制和结合e值与已建立方法的混合策略,已实现于开源R包`evalinger`中,并置于2026年1月FDA草案指南关于贝叶斯方法的监管框架内。

英文摘要:

Adaptive clinical trials rely on interim analyses, flexible stopping, and data-dependent design modifications that complicate statistical guarantees when fixed-horizon test statistics are repeatedly inspected or reused after adaptations. E-values and e-processes provide anytime-valid tests and confidence sequences that remain valid under optional stopping and optional continuation without requiring a prespecified monitoring schedule. This paper is a methodology guide for practitioners. We develop the betting-martingale construction of e-processes for two-arm randomized controlled trials, show how e-values naturally handle composite null hypotheses and support futility monitoring, and provide guidance on when e-values are appropriate, when established alternatives are preferable, and how to integrate e-value monitoring with group sequential and Bayesian adaptive workflows. A numerical study compares five monitoring rules -- naive and calibrated versions of frequentist, Bayesian, and e-value approaches -- in a two-arm binary-endpoint trial. Naive repeated testing and naive posterior thresholds inflate Type I error substantially under frequent interim looks. Among the valid methods, the calibrated group sequential rule achieves the highest power, the e-value rule provides robust anytime-valid control with moderate power, and the calibrated Bayesian rule is the most conservative. Extended simulations show that the power gap between group sequential and e-value methods depends on the monitoring schedule and reverses under continuous monitoring. The methodology, including futility monitoring, platform trial multiplicity control, and hybrid strategies combining e-values with established methods, is implemented in the open-source R package `evalinger` and situated within the regulatory framework of the January 2026 FDA draft guidance on Bayesian methodology.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑