arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2601.02447cs.CV

不要理会间隙:用于分辨率无关视网膜OCT分析的隐式神经表示

Don't Mind the Gaps: Implicit Neural Representations for Resolution-Agnostic Retinal OCT Analysis

Bennet Kahrs, Julia Andresen, Fenja Falta, Monty Santarossa, Heinz Handels, Timo Kepp

AI总结:

本文提出两种基于隐式神经表示的框架,用于解决视网膜OCT分析中因大间距B扫描导致的分辨率问题,通过插值和图谱构建实现分辨率无关的3D分析。

摘要:

常规的视网膜光学相干断层扫描(OCT)成像使用大切片间距进行,导致高度各向异性图像和稀疏扫描的视网膜。大多数基于学习的方法通过使用2D方法而不是进行体积分析来规避各向异性带来的问题。这些方法固有地存在在相邻B扫描中生成不一致结果的风险。例如,2D视网膜层分割可以在3D中呈现不规则表面。此外,通常使用的卷积神经网络受限于训练数据的分辨率,这阻止了它们用于使用不同成像协议获取的图像。隐式神经表示(INRs)最近作为一种工具出现,用于将体素化数据存储为连续表示。使用坐标作为输入,INRs是分辨率无关的,这使它们能够应用于各向异性的数据。在本文中,我们提出两个框架,利用INRs的这一特性,对视网膜OCT体积进行密集的3D分析。1)我们通过结合额外的面模态信息进行不同B扫描之间的插值,帮助在B扫描之间保留相关结构。2)我们创建了一个分辨率无关的视网膜图谱,使分析能够无需严格的数据要求。两种方法利用可推广的INRs,通过基于群体的训练改进视网膜形状表示,并允许对未见过的案例进行预测。我们的分辨率无关的框架促进了大B扫描距离OCT图像的分析,为视网膜结构和病理的体积分析开辟了可能性。

英文摘要:

Routine clinical imaging of the retina using optical coherence tomography (OCT) is performed with large slice spacing, resulting in highly anisotropic images and a sparsely scanned retina. Most learning-based methods circumvent the problems arising from the anisotropy by using 2D approaches rather than performing volumetric analyses. These approaches inherently bear the risk of generating inconsistent results for neighboring B-scans. For example, 2D retinal layer segmentations can have irregular surfaces in 3D. Furthermore, the typically used convolutional neural networks are bound to the resolution of the training data, which prevents their usage for images acquired with a different imaging protocol. Implicit neural representations (INRs) have recently emerged as a tool to store voxelized data as a continuous representation. Using coordinates as input, INRs are resolution-agnostic, which allows them to be applied to anisotropic data. In this paper, we propose two frameworks that make use of this characteristic of INRs for dense 3D analyses of retinal OCT volumes. 1) We perform inter-B-scan interpolation by incorporating additional information from en-face modalities, that help retain relevant structures between B-scans. 2) We create a resolution-agnostic retinal atlas that enables general analysis without strict requirements for the data. Both methods leverage generalizable INRs, improving retinal shape representation through population-based training and allowing predictions for unseen cases. Our resolution-independent frameworks facilitate the analysis of OCT images with large B-scan distances, opening up possibilities for the volumetric evaluation of retinal structures and pathologies.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑