arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2512.17137cs.CVcs.AI

SDUM:一种可扩展的深度展开模型用于通用MRI重建

SDUM: A Scalable Deep Unrolled Model for Universal MRI Reconstruction

Johns Hopkins University(约翰霍普金斯大学);NVIDIA

Puyang Wang, Pengfei Guo, Keyi Chai, Jinyuan Zhou, Daguang Xu, Shanshan Jiang

AI总结:

SDUM是一种结合Restormer、CSME、SWDC和UC的通用MRI重建框架,通过级联扩展训练实现可扩展性,无需微调即可在多个挑战赛道上取得最佳性能。

摘要:

临床MRI涵盖多种成像协议——从解剖目标(心脏、大脑、膝盖)、对比剂(T1、T2、映射)、采样模式(Cartesian、径向、螺旋、kt-space)以及加速因子等方面——然而当前的深度学习重建方法通常是协议特定的,限制了泛化能力和部署。我们引入了可扩展深度展开模型(SDUM),一种结合基于Restormer的重建器、学习的线圈灵敏度图估计器(CSME)、采样感知加权数据一致性(SWDC)、通用条件(UC)在级联索引和协议元数据上的应用,以及渐进级联扩展训练的通用框架。SDUM表现出基础模型般的扩展行为:重建质量遵循PSNR≈log(参数)与相关性r=0.986(R²=0.973)在18个级联中,证明了随着模型深度的增加,性能有可预测的提升。一个在异质数据上训练的SDUM在CMRxRecon2025挑战的所有四个赛道——多中心、多疾病、5T和儿童——上实现了最先进的结果,无需任务特定的微调,超过了专门的基线方法最高达+1.0 dB。在CMRxRecon2024上,SDUM超过获胜方法PromptMR+ 0.55 dB;在fastMRI脑部上,它超过PC-RNN 1.8 dB。消融实验验证了每个组件:SWDC比标准DC高0.43 dB,每个级联CSME高0.51 dB,UC高0.38 dB。这些结果确立了SDUM作为通用、可扩展MRI重建的实用路径。

英文摘要:

Clinical MRI encompasses diverse imaging protocols--spanning anatomical targets (cardiac, brain, knee), contrasts (T1, T2, mapping), sampling patterns (Cartesian, radial, spiral, kt-space), and acceleration factors--yet current deep learning reconstructions are typically protocol-specific, hindering generalization and deployment. We introduce Scalable Deep Unrolled Model (SDUM), a universal framework combining a Restormer-based reconstructor, a learned coil sensitivity map estimator (CSME), sampling-aware weighted data consistency (SWDC), universal conditioning (UC) on cascade index and protocol metadata, and progressive cascade expansion training. SDUM exhibits foundation-model-like scaling behavior: reconstruction quality follows PSNR ${\sim}$ log(parameters) with correlation $r{=}0.986$ ($R^2{=}0.973$) up to 18 cascades, demonstrating predictable performance gains with model depth. A single SDUM trained on heterogeneous data achieves state-of-the-art results across all four CMRxRecon2025 challenge tracks--multi-center, multi-disease, 5T, and pediatric--without task-specific fine-tuning, surpassing specialized baselines by up to ${+}1.0$~dB. On CMRxRecon2024, SDUM outperforms the winning method PromptMR+ by ${+}0.55$~dB; on fastMRI brain, it exceeds PC-RNN by ${+}1.8$~dB. Ablations validate each component: SWDC ${+}0.43$~dB over standard DC, per-cascade CSME ${+}0.51$~dB, UC ${+}0.38$~dB. These results establish SDUM as a practical path toward universal, scalable MRI reconstruction.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑