arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2512.14103physics.flu-dyn
收藏

通过稀疏传感器优化和非时间分辨PIV实现高效的时间分辨压力估计

Efficient Time-Resolved Pressure Estimation by Sparse Sensor Optimization and Non-Time-Resolved PIV

Indian Institute of Technology, Hyderabad(印度理工学院海得拉巴分校);Indian Institute of Technology, Roorkee(印度理工学院罗尔基分校)

Neetu Tiwari, Ajit Kumar Dubey

AI总结:

通过稀疏传感器优化和非时间分辨PIV数据,提出两种方法高效估计时间分辨压力场,方法二计算效率高约30倍。

摘要:

从PIV数据中估计压力场已是一项成熟的技术。然而,时间分辨的压力估计强烈依赖于PIV测量的时域分辨率。通常,PIV数据具有有限的时间分辨率,这给理解高雷诺数流动带来了挑战。为克服这一挑战,通过在少数优化位置测量具有更高时间分辨率的传感器数据,并结合PIV数据使用数据驱动方法,重建时间分辨的速度场。在此背景下,如果希望从非时间分辨的PIV数据中估计时间分辨的压力场,有两种可能的方法。方法1:首先从非时间分辨的PIV数据中利用传感器数据重建时间分辨的速度场,然后通过应用压力泊松方程来估计时间分辨的压力场。方法2:首先使用压力泊松方程从非时间分辨的速度场测量中估计非时间分辨的压力场,然后直接从非时间分辨的压力场中重建时间分辨的压力场。这两种方法在本研究中进行了比较。这些方法在实际的圆柱体流动PIV数据上得到了演示。时间分辨的PIV测量被下采样以模拟非时间分辨的速度数据。发现当时间分辨率从1Hz提高到50Hz时,方法二比方法一快大约30倍。这预计是因为在第二种方法中,压力泊松方程只需要用非时间分辨的速度场求解,从而减少了计算负载。

英文摘要:

Pressure field estimation from PIV data has been a well-established technique. However, time-resolved pressure estimation strongly depends on the temporal resolution of the PIV measurements. Generally, PIV data has limited time resolution creating challenges to understand high Reynolds number flows. To overcome this challenge, sensor data measured at few optimized locations with higher time resolution is combined with PIV data using data driven methods to reconstruct time resolved velocity fields. In this context, if we wish to estimate time resolved pressure fields from non-time resolved PIV data, there are two possible approaches. Approach 1: reconstruct time-resolved velocity field first from non-time resolved PIV data using sensor data, and then time-resolved pressure fields are estimated from time-resolved pressure fields by applying pressure Poisson equation. Approach 2: first estimate non-time resolved pressure fields from non-time resolved velocity field measurements using pressure Poisson equation and then reconstruct time resolved pressure fields directly from non-time resolved pressure fields. These two approaches are compared in this study. These approaches are demonstrated for actual PIV data of flow over a cylinder. Time-resolved PIV measurements are down-sampled to mimic non-time-resolved velocity data. It was found that the approach two is approximately thirty times faster than approach one when time resolution is improved from 1 Hz to 50 Hz. This is expected because in the second approach the pressure Poisson equation needs to be solved only with non-time resolved velocity fields which reduces the computational load.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑