arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2510.20570quant-ph
收藏

通过电流偏置约瑟夫森结测量弱微波信号 II:达到单光子探测灵敏度

Measuring weak microwave signals via current-biased Josephson Junctions II: Arriving at single-photon detection sensitivity

HergD collaboration and Information Quantum Technology Laboratory, School of Information Science and Technology, Southwest Jiaotong University(西南交通大学信息科学与技术学院量子信息技术实验室)

Y. Q. Chai, M. Y. Wang, S. N. Wang, P. H. Ouyang, L. F. Wei

AI总结:

本文通过数值模拟证明,非平衡约瑟夫森阈值探测器(JTD)相比平衡态JTD能实现更高的弱微波信号探测灵敏度,达到能量量子极限,并可用于单微波光子探测。

摘要:

众所周知,电流偏置约瑟夫森结(CBJJ)可作为约瑟夫森阈值探测器(JTD)用于弱微波信号的灵敏探测。基于最近关于通常平衡态JTD探测灵敏度极限的工作(PRB {\bf 111}, 024501 (2025)),本文通过数值模拟证明,非平衡JTD可替代性地用于实现弱微波信号的更高灵敏度探测,达到其能量量子极限。在存在热噪声的情况下,我们数值模拟了不同偏置电流扫描速率下JTD中CBJJ的相位动力学,发现有无微波信号输入时JTD的开关电流分布(SCD)表现出不同行为。结果表明,根据施加的偏置电流扫描速率的高低,JTD可工作在平衡态或非平衡态。具体而言,在快速非绝热驱动下,JTD的SCD明显对热噪声不敏感,这意味着非平衡JTD相比其平衡态对应物具有更高的可实现探测灵敏度。因此,非平衡JTD可用于实现所需的单微波光子探测。此外,当非平衡JTD作为宽带微波单光子探测器时,还评估了其一些可实现的性能指标,如动态范围、探测带宽和光子数分辨能力等。

英文摘要:

It is well known that the current-biased Josephson junction (CBJJ) can serve as a Josephson threshold detector (JTD) for the sensitive detection of weak microwave signals. Based on the recent work (PRB {\bf 111}, 024501 (2025)) on the detection sensitive limit of the usual equilibrium JTD, here we numerically demonstrate that a non-equilibrium JTD can be alternatively utilized to implement the higher sensitive detection of a weak microwave signal, arriving at its energy quantum limit. In the presence of thermal noise, we numerically simulate the phase dynamics for the CBJJ in the JTD with the different sweep rates of the biased currents, and find that the SCDs of the JTD with and without the microwave signal input show different behaviors. It is demonstrated that, depending on how high the sweep rate of the biased current being applied, the JTD can be operated in either the equilibrium- or the non-equilibrium state. Specifically, under the rapidly non-adiabatic driving, the SCDs of the JTD are obviously insensitive to the thermal noises, which means that the non-equilibrium JTD can possess a higher achievable detection sensitivity, compared with its equilibrium state counterpart. Consequently, the non-equilibrium JTD can be utilized to implement the desired single microwave-photon detection. Also, some of the achievable performance indexes, such as the dynamic range, detection bandwidth, and the photon-number resolvability, etc., of the non-equilibrium JTD have been estimated, when it serves as a wideband microwave single-photon detector.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑