Photoacoustic imaging (PAI) is a novel hybrid imaging technique that combines the benefits of both optical and acoustic imaging modalities, which provides functional and molecular optical contrasts of deep tissue. Commonly used ultrasound transducers for PAI include linear and planar arrays, which can provide two-dimensional (2D) and three-dimensional (3D) image reconstruction, respectively. However, linear arrays cannot provide reconstruction of 3D images, which makes it impossible to locate chromophores in 3D space. Although planar array can provide fast 3D imaging in real time, it usually requires thousands of analog-to-digital conversion channels for data acquisition, which is costly. To fill the gap between 2D and 3D PAI, we propose a quasi-planar array that uses double 16-elements-linear arrays arranged in parallel to achieve real-time 3D imaging. We first conducted simulation studies to prove that the quasi-planar probe can perform 3D imaging to localize simple chromophores. Then, the agarose phantom experiment demonstrated that the probe can reconstruct 3D imaging of multiple absorbers in different depths. A potential application of this device is to provide a low-cost 3D PAI solution for fast tracking of needle tip during needle biopsy, which will be further explored in our future work.
In Photoacoustic imaging (PAI), the most prevalent beamforming algorithm is delay-and-sum (DAS) due to its simple implementation. However, it results in a low quality image affected by the high level of sidelobes. Coherence factor (CF) can be used to address the sidelobes in the reconstructed images by DAS, but the resolution improvement is not good enough compared to the high resolution beamformers such as minimum variance (MV). As a weighting algorithm in linear-array PAI, it was proposed to use high-resolution-CF (HRCF) weighting technique in which MV is used instead of the existing DAS in …
Simultaneous 3D co-registered perfusion and oxygenation with ULM, photoacoustic imaging, and a planar matrix array
Sorbonne Université(索邦大学);CNRS(法国国家科学研究中心);Inserm(法国国家健康与医学研究院);Laboratoire d’Imagerie Biomédicale, LIB(生物医学成像实验室);Université Paris Cité(巴黎西岱大学);Centre de Recherche des Cordeliers(科尔德洛耶研究中心);Institut Cochin(科尚研究所);Department of Nuclear Medicine, Hôpital Pitié Salpêtrière, APHP(皮蒂埃-萨尔佩特里埃医院核医学科);PARCC(PARCC研究中心);Service de Radiologie, AP-HP, Hôpital européen Georges Pompidou(乔治·蓬皮杜欧洲医院放射科)
In linear-array transducer based photoacoustic (PA) imaging, B-scan PA images are formed using the raw channel PA signals. Delay-and-Sum (DAS) is the most prevalent algorithm due to its simple implementation, but it leads to low quality images. Delay-Multiply-and-Sum (DMAS) provides a higher image quality in comparison with DAS while it imposes a computational burden of O(M^2). In this work, we introduce a nonlinear (NL) beamformer for linear-array PA imaging, which uses the p^{th} root of the detected signals and imposes the complexity of DAS (O(M)). The proposed algorithm is evaluated numeri…
Delay-and-sum (DAS) algorithms are widely used for beamforming in linear array photoacoustic imaging systems and are characterized by fast execution. However, these algorithms suffer from various drawbacks like low resolution, low contrast, high sidelobe artifacts and lack of visual coherence. More recently, adaptive weighting was introduced to improve the reconstruction image quality. Unfortunately, the existing state-of-the-art adaptive beamforming algorithms are computationally expensive and do not consider the specific noise characteristics of the acquired ultrasonic signal. In this articl…
This paper reports an aluminum nitride (AlN) multi-frequency piezoelectric micromachined ultrasound transducers (MF-PMUT) array for photoacoustic (PA) imaging, where the broadened bandwidth is beneficial to improve imaging resolution. Specifically, PMUT based on micro-electromechanical systems (MEMS) technology is suitable for PA endoscopic imaging of blood vessels and bronchi due to its miniature size. More importantly, AlN is a non-toxic material, which makes it harmless for biomedical applications. In this work, a MF-PMUT array are designed and fabricated for PAI. The device's vibration mod…
Photoacoustic imaging (PAI) is a promising medical imaging modality providing the spatial resolution of ultrasound (US) imaging and the contrast of pure optical imaging. For linear-array PAI, a beamformer has to be used as the reconstruction algorithm. Delay-and-sum (DAS) is the most prevalent beamforming algorithm in PAI. However, using DAS beamformer leads to low resolution images along with significant effects of the off-axis signals. Coherence factor (CF) is a weighting method in which each pixel of the reconstructed image is weighted, based on the spatial spectrum of the aperture, to impr…
Photoacoustic tomography (PAT) combines the advantages of the spectroscopic optical absorption contrast and acoustic resolution with deep penetration, and becomes an important novel biomedical imaging technology for scientific research and clinical diagnosis. In this paper, an imaging size-adjustable PAT system is proposed for clinical applications, which can adapt for different size imaging targets. Comparing with the conventional PAT system setup which with a fixed radius ring shape ultrasound transducer (UT) array, the proposed system, which is based on sectorial ultrasound transducer array…
Photoacoustic imaging can achieve high-resolution three-dimensional visualization of optical absorbers at penetration depths ~ 1 cm in biological tissues by detecting optically-induced high ultrasound frequencies. Tomographic acquisition with ultrasound linear arrays offers an easy implementation of single-side access, parallelized and high-frequency detection, but usually comes with an image quality impaired by the directionality of the detectors. Indeed, a simple translation of the array perpendicularly to its median imaging plane is often used, but results both in a poor resolution in the t…
As an emerging medical diagnostic technology, photoacoustic imaging has been implemented for both preclinical and clinical applications. For clinical convenience, a handheld free scan photoacoustic tomography (PAT) system providing 3D imaging capability is essentially needed, which has potential for surgical navigation and disease diagnosis. In this paper, we proposed a free scan 3D PAT (fsPAT) system based on a handheld linear array ultrasound probe. A global positioning system (GPS) is applied for ultrasound probes coordinate acquisition. The proposed fsPAT can simultaneously realize real ti…
Photoacoustic (PA) imaging systems based on clinical linear ultrasound arrays have become increasingly popular in translational PA research. Such systems can be more easily integrated in a clinical workflow due to the simultaneous access to ultrasonic imaging and their familiarity of use to clinicians. In contrast to more complex setups, hand held linear probes can be applied to a large variety of clinical use cases. However, most translational work with such scanners is based on proprietary development and as such not accessible to the community. In this contribution, we present a custom-buil…
Significance: We proposed a new design of hand-held linear-array photoacoustic (PA) probe which can acquire multi images via motor moving. Moreover, images from different locations are utilized via imaging fusion for SNR enhancement. Aim: We devised an adjustable hand-held for the purpose of realizing different images at diverse location for further image fusion. For realizing the light spot which is more matched with the Ultrasonic transducer detection area, we specially design a light adjust unit. Moreover, due to no displacement among the images, there is no need to execute image register p…
Linear-array based photoacoustic images are reconstructed using the conventional delay-and-sum (DAS) beamforming method. Although the DAS beamformer is well suited for PA image formation, reconstructed images are often afflicted by noises, sidelobes, and other intense artifacts due to inaccurate assumptions of PA signal correlation. The work aims to develop an inversion method that reduces the occurrence of sidelobes and artifacts and improves image quality performance. We present a novel beamformer based on higher-order signal correlation, where more number of delayed PA signals are combined …
Photoacoustic computed tomography (PACT) combines the optical contrast of optical imaging and the penetrability of sonography. In this work, we develop a novel PACT system to provide real-time imaging, which is achieved by a 120-elements ultrasound array only using a single data acquisition (DAQ) channel. To reduce the channel number of DAQ, we superimpose 30 nearby channels' signals together in the analog domain, and shrinking to 4 channels of data (120/30=4). Furthermore, a four-to-one delay-line module is designed to combine these four channels' data into one channel before entering the sin…
In optoacoustic (photoacoustic) tomography, several parameters related to tissue and detector features are needed for image formation, but they may not be known a priori. An autofocus (AF) algorithm is generally used to estimate these parameters. However, the algorithm works iteratively, therefore, it is impractical for clinical imaging with systems featuring planar geometry due to long reconstruction times. We have developed a fast autofocus (FAF) algorithm for optoacoustic systems with planar geometry that is much simpler computationally than the conventional AF algorithm. We show that the F…
Photoacoustic imaging of human brain function through intact adult skulls
California Institute of Technology(加州理工学院);Case Western Reserve University(凯斯西储大学);University of Southern California(南加州大学);Midjourney, Inc.(Midjourney公司);Changsha University of Science and Technology(长沙理工大学);Peking University(北京大学);European Molecular Biology Laboratory(欧洲分子生物学实验室);Rice University(莱斯大学);Tsinghua University(清华大学)