arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2508.09285physics.med-ph
收藏

动态患者特异性左房室瓣模型的修复仿真

Simulation of Repair on Dynamic Patient-Specific Left Atrioventricular Valve Models

Children’s Hospital of Philadelphia(费城儿童医院);Archetype Medical Inc.(Archetype医疗公司);Robarts Research Institute, Western University(韦仕敦大学罗伯茨研究所)
Stephen Ching, Christopher Zelonis, Christian Herz, Patricia Sabin, Matthew Daemer, Muhammad Nuri, Yan Wang, Devin W. Laurence, Jonathan M. Chen, Lindsay S. Rog… 展开作者

Stephen Ching, Christopher Zelonis, Christian Herz, Patricia Sabin, Matthew Daemer, Muhammad Nuri, Yan Wang, Devin W. Laurence, Jonathan M. Chen, Lindsay S. Rogers, Michael D. Quartermain, John Moore, Terry Peters, Elvis Chen, Matthew A. Jolley

AI总结:

本研究开发并评估了一种动态患者特异性左房室瓣物理仿真平台,用于儿科修复策略的临床前测试,通过硅胶模型和脉搏复制器比较多种修复技术,证明了其在优化手术方案方面的可行性。

摘要:

目的:开发并评估一种动态的、基于图像的患者特异性物理仿真平台,用于评估已修复房室间隔缺损的儿科患者左房室瓣(LAVV)修复策略。方法:从机构数据库中识别出两名患有反流性左房室瓣患者的3D经食管超声心动图图像。使用SlicerHeart中的自定义代码对瓣叶进行分割、定义瓣环,并生成患者特异性瓣膜模具。制作硅胶瓣膜模型,并在模拟生理条件下的脉搏复制器中测试。分析了五个未修复瓣膜的制造一致性,并针对两个患者特异性模型比较了多种手术修复技术。结果:瓣环指标的制造变异性较低(瓣环周长的变异系数:2.1;连合距离:4.1;瓣环高度:14.7),但瓣叶闭合指标(膨隆高度:11.1%;膨隆体积:18.9%;帐篷高度:45.9%;帐篷体积:73.5%)的变异性较高。在患者1中,裂口闭合和Alfieri缝合均消除了反流口面积,但Alfieri缝合导致平均压力梯度升高(17 mmHg,而其他修复为4-9 mmHg),并在重复加载后恶化。在患者2中,没有一种修复完全消除反流;然而,将11 mm补片增宽与连合成形术相结合,将反流面积减少至0.147 cm²,这是所测试策略中观察到的最小值。结论:本研究证明了动态物理仿真平台用于临床前左房室瓣修复评估的可行性。这项概念验证工作凸显了该平台在临床应用前优化修复策略的潜力,这可能对患有先天性心脏病的小规模和异质性人群尤其相关。

英文摘要:

Purpose: To develop and evaluate a dynamic, image-derived patient-specific physical simulation platform for the assessment of left atrioventricular valve (LAVV) repair strategies in pediatric patients with repaired atrioventricular canal defects. Methods: 3D transesophageal echocardiographic images of two patients with regurgitant LAVVs were identified from an institutional database. Custom code in SlicerHeart was used to segment leaflets, define the annulus, and generate patient-specific valve molds. Silicone valve models were fabricated and tested in a pulse duplicator under simulated physiological conditions. Five unrepaired valves were analyzed for manufacturing consistency, and multiple surgical repair techniques were compared for two patient-specific models. Results: Manufacturing variability was low in annular metrics (CV for annular circumference: 2.1; commissural distance: 4.1; annulus height: 14.7) but higher in leaflet closure metrics (billow height: 11.1%; billow volume: 18.9%; tenting height: 45.9%; tenting volume: 73.5%). In Patient 1, cleft closure and an Alfieri stitch both eliminated the regurgitant orifice area, but the Alfieri stitch resulted in elevated mean pressure gradient (17 mmHg vs. 4-9 mmHg for other repairs) and deteriorated with repeated loading. In Patient 2, no repair eliminated regurgitation entirely; however, combining an 11 mm patch augmentation with commissuroplasty reduced regurgitant area to 0.147 cm2, the smallest observed among tested strategies. Conclusion: This study demonstrates the feasibility of a dynamic physical simulation platform for preclinical LAVV repair evaluation. This proof-of-concept work highlights the platform potential for refining repair strategies before clinical application, which may be particularly relevant in small and heterogeneous populations with congenital heart disease.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑