考虑到外科医生在二尖瓣修复手术中面临的众多挑战,他们在进入手术室之前应该对手术工具的操作和手术技术的应用有很高的信心。不幸的是,微创修复手术培训的机会非常有限,导致大多数外科医生在操作第一批患者时经历陡峭的学习曲线。为了提供一个逼真的手术培训工具,一个商业模拟器增强了灵活的患者特定的二尖瓣复制品。在经过多次优化循环后最终完成的精心制作的生产管道中,模型从3D超声中分割出来,然后自动计算3D可打印模具,并用刚性材料打印,下部是水溶性的。在硅树脂注射后,将硅树脂模型从模具中溶解并锚定在模拟器中。据我们所知,我们的模型是第一个包含完整二尖瓣装置的模型,即瓣环、瓣叶、腱索和乳头肌。根据拟定的工作流程自动创建了9个不同的瓣膜模具(7个脱垂瓣膜和2个功能性二尖瓣关闭不全瓣膜)。从这些模具的几何形状,16复制品制造。材料试验表明,在7种混合物中,Ecoflex \textsuperscript{TM} 00-30是最适合小叶模拟组织的材料。每个瓣膜的生产时间约为36小时。12名外科医生进行了各种手术技术,例如瓣环成形术、新腱索植入术、三角瓣叶切除术,并对瓣膜的真实性进行了非常积极的评估。标准化的生产工艺保证了硅胶阀与分段模型和超声数据的高度解剖再现。

英文摘要:

Given the multitude of challenges surgeons face during mitral valve repair surgery, they should have a high confidence in handling of instruments and in the application of surgical techniques before they enter the operating room. Unfortunately, opportunities for surgical training of minimally-invasive repair are very limited, leading to a situation where most surgeons undergo a steep learning curve while operating the first patients. In order to provide a realistic tool for surgical training, a commercial simulator was augmented by flexible patient-specific mitral valve replica. In an elaborated production pipeline, finalized after many optimization cycles, models were segmented from 3D ultrasound and then 3D-printable molds were computed automatically and printed in rigid material, the lower part being water-soluble. After silicone injection, the silicone model was dissolved from the mold and anchored in the simulator. To our knowledge, our models are the first to comprise the full mitral valve apparatus, i.e. the annulus, leaflets, chordae tendineae and papillary muscles. Nine different valve molds were automatically created according to the proposed workflow (seven prolapsed valves and two valves with functional mitral insufficiency). From these mold geometries, 16 replica were manufactured. A material test revealed that Ecoflex\textsuperscript{TM} 00-30 is the most suitable material for leaflet-mimicking tissue out of seven mixtures. Production time was around 36h per valve. Twelve surgeons performed various surgical techniques, e.g. annuloplasty, neo-chordae implantation, triangular leaflet resection and assessed the realism of the valves very positively. The standardized production process guarantees a high anatomical recapitulation of the silicone valves to the segmented models and the ultrasound data...

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑