arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2502.04941physics.ins-det
收藏

弯曲至不同半径的单片有源像素传感器的探测效率与空间分辨率

Detection efficiency and spatial resolution of Monolithic Active Pixel Sensors bent to different radii

Anton Andronic, Pascal Becht, Mihail Bogdan Blidaru, Giuseppe Eugenio Bruno, Francesca Carnesecchi, Emma Chizzali, Domenico Colella, Manuel Colocci, Giacomo Con… 展开作者

Anton Andronic, Pascal Becht, Mihail Bogdan Blidaru, Giuseppe Eugenio Bruno, Francesca Carnesecchi, Emma Chizzali, Domenico Colella, Manuel Colocci, Giacomo Contin, Laura Fabbietti, Roman Gernhäuser, Hartmut Hillemanns, Nicolo Jacazio, Alexander Philipp Kalweit, Alex Kluge, Artem Kotliarov, Filip Křížek, Lukas Lautner, Magnus Mager, Paolo Martinengo, Silvia Masciocchi, Marius Wilm Menzel, Alice Mulliri, Felix Reidt, Riccardo Ricci, Roberto Russo, David Schledewitz, Gilda Scioli, Serhiy Senyukov, Sabyasachi Siddhanta, Jory Sonneveld, Johanna Stachel, Miljenko Šuljić, Nicolas Tiltmann, Arianna Grisel Torres Ramos, Berkin Ulukutlu, Gianluca Usai, Jacob Bastiaan Van Beelen, Yitao Wu, Alperen Yüncü

AI总结:

本文通过测试束流实验验证了弯曲至18、24和30 mm半径的50 μm厚ALPIDE芯片,在标称条件下获得大于99.9%的效率和约5 μm的空间分辨率,且性能与弯曲半径无关,证明了ALICE ITS3探测器的可行性。

摘要:

弯曲的单片有源像素传感器是ALICE实验计划中的全圆柱形超低物质量径迹探测器ITS3的基础。本文介绍了使用高能粒子进行的测试束流实验的结果,以验证厚度为50 μm的弯曲ALPIDE芯片在效率和空间分辨率方面的性能。传感器被弯曲至18、24和30 mm的半径,略小于未来ALICE ITS3各层所预见的弯曲半径。在标称工作条件下,获得了大于99.9%的效率以及约5 μm的空间分辨率,这与平坦ALPIDE传感器的标称工作性能一致。这些数值被发现与弯曲半径无关,从而构成了证明计划中的ITS3探测器可行性的又一个里程碑。此外,还研究了一种特殊几何结构,其中束流粒子掠过芯片并沿横向穿过芯片,距离可达3 mm。

英文摘要:

Bent monolithic active pixel sensors are the basis for the planned fully cylindrical ultra low material budget tracking detector ITS3 of the ALICE experiment. This paper presents results from testbeam campaigns using high-energy particles to verify the performance of 50 um thick bent ALPIDE chips in terms of efficiency and spatial resolution. The sensors were bent to radii of 18, 24 and 30 mm, slightly smaller than the foreseen bending radii of the future ALICE ITS3 layers. An efficiency larger than $99.9\%$ and a spatial resolution of approximately 5 um, in line with the nominal operation of flat ALPIDE sensors, is obtained at nominal operating conditions. These values are found to be independent of the bending radius and thus constitute an additional milestone in the demonstration of the feasibility of the planned ITS3 detector. In addition, a special geometry in which the beam particles graze the chip and traverse it laterally over distances of up to 3 mm is investigated.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑