arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2501.17286physics.med-phcs.AIcs.CL
收藏

微调开源大型语言模型以提升其在放射肿瘤学任务中的表现:探究其在放射肿瘤学中潜在临床应用的可行性研究

Fine-Tuning Open-Source Large Language Models to Improve Their Performance on Radiation Oncology Tasks: A Feasibility Study to Investigate Their Potential Clinical Applications in Radiation Oncology

Mayo Clinic Arizona(梅奥诊所亚利桑那院区);University of Georgia(佐治亚大学);Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院)
Peilong Wang, Zhengliang Liu, Yiwei Li, Jason Holmes, Peng Shu, Lian Zhang, Xiang Li, Quanzheng Li, Brady S. Laughlin, Diego Santos Toesca, Sujay A. Vora, Samir… 展开作者

Peilong Wang, Zhengliang Liu, Yiwei Li, Jason Holmes, Peng Shu, Lian Zhang, Xiang Li, Quanzheng Li, Brady S. Laughlin, Diego Santos Toesca, Sujay A. Vora, Samir H. Patel, Terence T. Sio, Tianming Liu, Wei Liu

AI总结:

本研究利用放射肿瘤学领域数据微调LLaMA2-7B和Mistral-7B模型,在治疗方案生成、治疗方式选择和ICD-10代码预测三项任务上均显著优于原始模型,且超60%生成方案获临床认可。

摘要:

背景:放射肿瘤学临床实践包含许多依赖大量文本数据动态交互的步骤。大型语言模型在处理复杂文本信息方面展现出卓越能力,但其在放射肿瘤学等特定领域的直接应用仍研究不足。目的:本研究旨在探究利用领域知识微调LLMs能否改善其在放射肿瘤学中Task (1)治疗方案生成、Task (2)治疗方式选择(光子、质子、电子或近距离放射治疗)以及Task (3)ICD-10代码预测三项任务上的表现。方法:提取了15,724个患者病例数据。筛选具有单一诊断记录和明确可识别主要治疗计划的病例进行预处理和人工标注,最终获得7,903例包含患者诊断、治疗计划、治疗方式和ICD-10代码的病例。每个病例用于构建一对由患者诊断细节和答案(分别为治疗方案、治疗方式或ICD-10代码)组成的数据,用于这三项任务的监督微调。采用开源LLaMA2-7B和Mistral-7B模型,通过Low-Rank Approximations方法进行微调。报告了微调模型和原始模型的准确率及ROUGE-1分数。Task (1)由放射肿瘤学家进行临床评估,而Task (2)和(3)则评估精确率、召回率和F1分数。使用单侧Wilcoxon符号秩检验对结果进行统计分析。结果:微调后的LLMs在所有任务中均优于原始LLMs,p值<=0.001。临床评估表明,超过60%由微调LLMs生成的治疗方案在临床上可接受。精确率、召回率和F1分数显示微调LLMs的性能得到提升。

英文摘要:

Background: The radiation oncology clinical practice involves many steps relying on the dynamic interplay of abundant text data. Large language models have displayed remarkable capabilities in processing complex text information. But their direct applications in specific fields like radiation oncology remain underexplored. Purpose: This study aims to investigate whether fine-tuning LLMs with domain knowledge can improve the performance on Task (1) treatment regimen generation, Task (2) treatment modality selection (photon, proton, electron, or brachytherapy), and Task (3) ICD-10 code prediction in radiation oncology. Methods: Data for 15,724 patient cases were extracted. Cases where patients had a single diagnostic record, and a clearly identifiable primary treatment plan were selected for preprocessing and manual annotation to have 7,903 cases of the patient diagnosis, treatment plan, treatment modality, and ICD-10 code. Each case was used to construct a pair consisting of patient diagnostics details and an answer (treatment regimen, treatment modality, or ICD-10 code respectively) for the supervised fine-tuning of these three tasks. Open source LLaMA2-7B and Mistral-7B models were utilized for the fine-tuning with the Low-Rank Approximations method. Accuracy and ROUGE-1 score were reported for the fine-tuned models and original models. Clinical evaluation was performed on Task (1) by radiation oncologists, while precision, recall, and F-1 score were evaluated for Task (2) and (3). One-sided Wilcoxon signed-rank tests were used to statistically analyze the results. Results: Fine-tuned LLMs outperformed original LLMs across all tasks with p-value <= 0.001. Clinical evaluation demonstrated that over 60% of the fine-tuned LLMs-generated treatment regimens were clinically acceptable. Precision, recall, and F1-score showed improved performance of fine-tuned LLMs.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑