arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2501.12580cond-mat.mes-hall
收藏

弯曲对电极静电效应对发射体场增强的普适标度

Universal scaling of electrostatic effects of a curved counter-electrode on the emitter field enhancement

Thiago A. de Assis, Fernando F. Dalll'Agnol

AI总结:

针对单尖端纳米发射体场电子发射实验中对电极曲率对顶点场增强因子影响不明的问题,本文理论探究球形对电极曲率对HCP发射体的影响,发现普适标度关系,部分解释了传统实验中$γ_{\rm{Ca}}$低估$γ_{\rm{Pa}}$的差异。

摘要:

单尖端纳米发射体的场电子发射实验通常使用曲率半径为$R$的对电极,其与发射体顶点的距离为$d_{\rm{gap}}$。对电极曲率对发射体顶点场增强因子($γ_{\rm{Ca}}$)的影响尚不清楚。在本文中,我们从理论上探究了由圆柱柱上半球(HCP)表示、顶点半径$r_{\rm{a}}=50$nm的发射体的顶点场增强因子如何受球形对电极曲率的影响。重要的是,我们的结果表明,对于锐度纵横比通常在$10^2$到$10^3$之间的HCP,存在普适标度:$γ_{\rm{Ca}}=γ_{\rm{Pa}}Ψ({R}/{d_{\rm{gap}}})$,其中$γ_{\rm{Pa}}$是假设平面对电极时发射体的顶点场增强因子,$Ψ({R}/{d_{\rm{gap}}})$是普适标度函数——当${R}/{d_{\rm{gap}}}\nn1$时$Ψ\nsim1$,当${R}/{d_{\rm{gap}}}\nnll1$时$Ψ\nsim({R}/{d_{\rm{gap}}})^α$($α$接近1)。这些发现部分解释了传统场电子发射实验中的差异:当$R\nsim d_{\rm{gap}}\nn1r_{\rm{a}}$时,从单尖端碳纳米管的电流-电压特性中提取的有效$γ_{\rm{Ca}}$值通常低估理论$γ_{\rm{Pa}}$值,这一趋势与我们的结果预测一致。

英文摘要:

Experiments on field electron emission from single-tip nanoemitters have typically been carried out using a counter-electrode with a finite curvature radius $R$, positioned at a distance $d_{\rm{gap}}$ from the emitter's apex. The effects of the counter-electrode's curvature on the apex field enhancement factor ($γ_{\rm{Ca}}$) of the emitter are still not understood. In this Letter, we theoretically explore how the apex field enhancement factor of an emitter, represented by a hemisphere on a cylindrical post (HCP) with apex radius $r_{\rm{a}} = 50$nm, is influenced by the curvature of a spherical-shaped counter-electrode. Importantly, our results show that for HCPs with sharpness aspect ratios typically between $10^2$ and $10^3$, there is a universal scaling such that $γ_{\rm{Ca}} = γ_{\rm{Pa}} Ψ\left({R}/{d_{\rm{gap}}} \right)$, where $γ_{\rm{Pa}}$ represents the apex field enhancement factor for the emitter assuming a planar counter-electrode, and $Ψ\left({R}/{d_{\rm{gap}}} \right)$ is a universal scaling function such that $Ψ\sim 1$ for ${R}/{d_{\rm{gap}}} \gg 1$ and $Ψ\sim \left({R}/{d_{\rm{gap}}} \right)^α$, with $α$ close to unity, for $ {R}/{d_{\rm{gap}}} \ll 1$. These findings help partially explain discrepancies observed in orhtodox field electron emission experiments, who reported that the effective $γ_{\rm{Ca}}$ values extracted from the current-voltage characteristics of single-tip carbon nanotubes typically underestimate the theoretical $γ_{\rm{Pa}}$ values when $R \sim d_{\rm{gap}} \gg r_{\rm{a}}$, a trend that is predicted by our results.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑