arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2501.04727eess.SYcs.SY
收藏

一种利用有限电流测量值进行输电线路故障定位稀疏估计的新型欠定框架

A New Underdetermined Framework for Sparse Estimation of Fault Location for Transmission Lines Using Limited Current Measurements

Guangxiao Zhang, Gaoxi Xiao, Xinghua Liu, Yan Xu, Peng Wang

AI总结:

针对输电线路故障定位,提出一种结合电流测量与支路-母线矩阵的欠定稀疏估计框架,并采用鲁棒YALL1算法抑制多个异常值干扰;IEEE 39节点系统验证了其有效性与鲁棒性。

摘要:

本信函提出了一种用于故障定位的替代性欠定框架,该框架利用电流测量值以及支路-母线矩阵,提供了除传统基于电压的方法之外的另一种选择。为在存在多个异常值时提高故障定位精度,采用鲁棒YALL1算法来抵抗异常值干扰并准确恢复稀疏向量,从而精确定位故障。在IEEE 39节点测试系统上的结果证明了所提方法的有效性和鲁棒性。

英文摘要:

This letter proposes an alternative underdetermined framework for fault location that utilizes current measurements along with the branch-bus matrix, providing another option besides the traditional voltage-based methods. To enhance fault location accuracy in the presence of multiple outliers, the robust YALL1 algorithm is used to resist outlier interference and accurately recover the sparse vector, thereby pinpointing the fault precisely. The results on the IEEE 39-bus test system demonstrate the effectiveness and robustness of the proposed method.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑