arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2501.03513astro-ph.GAastro-ph.IMastro-ph.SR
收藏

S-PLUS超短巡天:利用BEst STar数据库进行测光再校准

The S-PLUS Ultra-Short Survey: Photometric Re-calibration with the BEst STar Database

Xiaolu Li, Kai Xiao, Yang Huang, Haibo Yuan, Yanke Tang, Timothy C. Beers, Bowen Huang, Mingyang Ma, Pedro K. Humire, Alvaro Alvarez-Candal, Federico Sestito, N… 展开作者

Xiaolu Li, Kai Xiao, Yang Huang, Haibo Yuan, Yanke Tang, Timothy C. Beers, Bowen Huang, Mingyang Ma, Pedro K. Humire, Alvaro Alvarez-Candal, Federico Sestito, Ning Gai, Yongna Mao, Hongrui Gu, Zhenzhao Tao, Lin Yang, Shuai Xu, Rong Hu

AI总结:

本文基于BEST数据库数万颗标准星,校正S-PLUS USS DR1的零点空间变化与CCD位置系统误差,将12波段测光零点精度提升约六倍。

摘要:

我们利用来自BEst STar(BEST)数据库的约30,000–70,000颗标准星,对S-PLUS超短巡天(Ultra-Short Survey,USS)DR1的12波段测光进行独立验证和全面再校准。我们识别出零点偏移的空间变化:在蓝色滤光片(u、J0378、J0395)中高达30–40 mmag,在其他滤光片中为10 mmag,这主要源于原始USS校准所采用技术的较高不确定性。此外,我们探测到大尺度和中尺度依赖于CCD位置的系统误差,最高达50 mmag,主要由不同的孔径和平场校正造成。随后,我们通过使用二阶二维多项式拟合并结合数值恒星平场校正方法,对每个tile的系统偏移进行校正,从而再校准USS DR1测光。来自XPSP和SCR标准的再校准结果在USS零点中一致至6 mmag以内,既展示了再校准后USS测光的典型精度,也表明USS零点精度提高了六倍。使用SDSS和Pan-STARRS1以及LAMOST DR10和Gaia测光进行的进一步验证,也确认了再校准后USS测光的这一精度。我们的结果清楚证明了BEST数据库能够高效地将宽场测光巡天的校准精度提升至毫星等水平。再校准后的USS DR1测光是公开可用的:doi: 10.12149/101503(https://nadc.china-vo.org/res/r101504/)。

英文摘要:

We present an independent validation and comprehensive re-calibration of S-PLUS Ultra-Short Survey (USS) DR1 12-band photometry using about 30,000--70,000 standard stars from the BEst STar (BEST) database. We identify spatial variation of zero-point offsets, up to 30--40\,mmag for blue filters ($u$, $J0378$, $J0395$) and 10\,mmag for others, predominantly due to the higher uncertainties of the technique employed in the original USS calibration. Moreover, we detect large- and medium-scale CCD position-dependent systematic errors, up to 50\,mmag, primarily caused by different aperture and flat-field corrections. We then re-calibrate the USS DR1 photometry by correcting the systematic shifts for each tile using second-order two-dimensional polynomial fitting combined with a numerical stellar flat-field correction method. The re-calibrated results from the XPSP and the SCR standards are consistent within 6\,mmag in the USS zero-points, demonstrating both the typical precision of re-calibrated USS photometry and a sixfold improvement in USS zero-point precision. Further validation using SDSS and Pan-STARRS1, as well as LAMOST DR10 and Gaia photometry, also confirms this precision for the re-calibrated USS photometry. Our results clearly demonstrate the capability and the efficiency of the BEST database in improving calibration precision to the milli-magnitude level for wide-field photometric surveys. The re-calibrated USS DR1 photometry is publicly available: doi: 10.12149/101503 (https://nadc.china-vo.org/res/r101504/).

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑