arXiv 2411.19593eess.IVcs.CVcs.LG

自监督去噪器框架

Self-Supervised Denoiser Framework

Emilien Valat, Andreas Hauptmann, Ozan Öktem

AI总结:

针对工业CT欠采样导致的图像质量问题,提出自监督去噪器框架(SDF),通过正弦图空间的子集预测任务训练去噪器,无需真实图像,提升重建质量且适用于少数据微调,性能优于现有方法。

摘要:

在工业场景中使用计算机断层扫描(CT)重建图像会面临与其他领域(如临床CT)不同的特定挑战。实际上,工业CT的无损检测通常需要扫描多个相似物体,同时保持高吞吐量,这就要求较短的扫描时间,而这在临床CT中并非关键问题。对断层扫描数据(正弦图)进行欠采样是减少扫描时间的自然方法,但代价是图像质量下降,因为图像质量取决于测量次数。在这种情况下,需要后处理技术来补偿由正弦图稀疏性引起的图像伪影。我们提出了自监督去噪器框架(SDF),这是一种自监督训练方法,利用在高采样正弦图数据上的预训练来提升从欠采样正弦图数据重建的图像质量。SDF的主要贡献在于,它通过将学习任务设置为从一个正弦图子集预测另一个子集,在正弦图空间中训练图像去噪器。因此,它不需要真实图像数据,利用了CT中丰富的正弦图数据模态,并且可以大幅提升从少量测量数据重建的图像质量。我们证明,在2D扇形束或3D锥形束CT设置中,SDF在峰值信噪比方面产生的图像质量优于其他分析型和自监督框架。此外,我们表明,当在少量样本上微调图像去噪器时,SDF提供的增强效果仍然存在,这使其成为在高质量图像数据稀缺的场景中合适的预训练技术。我们的结果基于实验数据集得出,使SDF成为CT中基础图像增强模型的有力候选构建块。

英文摘要:

Reconstructing images using Computed Tomography (CT) in an industrial context leads to specific challenges that differ from those encountered in other areas, such as clinical CT. Indeed, non-destructive testing with industrial CT will often involve scanning multiple similar objects while maintaining high throughput, requiring short scanning times, which is not a relevant concern in clinical CT. Under-sampling the tomographic data (sinograms) is a natural way to reduce the scanning time at the cost of image quality since the latter depends on the number of measurements. In such a scenario, post-processing techniques are required to compensate for the image artifacts induced by the sinogram sparsity. We introduce the Self-supervised Denoiser Framework (SDF), a self-supervised training method that leverages pre-training on highly sampled sinogram data to enhance the quality of images reconstructed from undersampled sinogram data. The main contribution of SDF is that it proposes to train an image denoiser in the sinogram space by setting the learning task as the prediction of one sinogram subset from another. As such, it does not require ground-truth image data, leverages the abundant data modality in CT, the sinogram, and can drastically enhance the quality of images reconstructed from a fraction of the measurements. We demonstrate that SDF produces better image quality, in terms of peak signal-to-noise ratio, than other analytical and self-supervised frameworks in both 2D fan-beam or 3D cone-beam CT settings. Moreover, we show that the enhancement provided by SDF carries over when fine-tuning the image denoiser on a few examples, making it a suitable pre-training technique in a context where there is little high-quality image data. Our results are established on experimental datasets, making SDF a strong candidate for being the building block of foundational image-enhancement models in CT.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑