arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2411.07172hep-ex
收藏

ADMX轴子搜索中改进的接收器噪声校准:4.54至5.41 $μ$eV

Improved Receiver Noise Calibration for ADMX Axion Search: 4.54 to 5.41 $μ$eV

M. Guzzetti, D. Zhang, C. Goodman, C. Hanretty, J. Sinnis, L. J Rosenberg, G. Rybka, John Clarke, I. Siddiqi, A. S. Chou, M. Hollister, S. Knirck, A. Sonnensche… 展开作者

M. Guzzetti, D. Zhang, C. Goodman, C. Hanretty, J. Sinnis, L. J Rosenberg, G. Rybka, John Clarke, I. Siddiqi, A. S. Chou, M. Hollister, S. Knirck, A. Sonnenschein, T. J. Caligiure, J. R. Gleason, A. T. Hipp, P. Sikivie, M. E. Solano, N. S. Sullivan, D. B. Tanner, R. Khatiwada, G. Carosi, N. Du, C. Cisneros, N. Robertson, N. Woollett, L. D. Duffy, C. Boutan, T. Braine, N. S. Oblath, M. S. Taubman, E. Lentz, E. J. Daw, C. Mostyn, M. G. Perry, C. Bartram, T. A. Dyson, C. L. Kuo, S. Ruppert, M. O. Withers, A. K. Yi, B. T. McAllister, J. H. Buckley, C. Gaikwad, J. Hoffman, K. Murch, J. Russell, M. Goryachev, E. Hartman, A. Quiskamp, M. E. Tobar

AI总结:

本研究以ADMX为案例,推导轴子晕镜接收器的理论噪声模型,通过1280 MHz噪声校准测量发现腔与JPA的未知相互作用,明确系统噪声温度的系统不确定性,为未来降低噪声温度提供参考。

摘要:

轴子是一种具有充分理论动机的暗物质候选粒子。搜索轴子暗物质的主流方法被称为轴子晕镜(axion haloscope),该方法利用轴子在强磁场中转化为光子的效应开展探测。然而,由于轴子与光子的耦合极弱,预期的信号强度格外微弱。为提升信号强度,许多晕镜采用共振增强技术和高增益放大器,同时采取措施尽可能降低接收器噪声,例如使用稀释制冷机和超低噪声电子器件。\n本文以轴子暗物质实验(Axion Dark Matter eXperiment, ADMX)为案例研究,基于典型轴子晕镜接收器链路中的噪声源,推导了理论噪声模型。我们展示了ADMX最近一次取数运行期间在1280 MHz频率下开展的不同噪声校准测量的实例。这些新结果揭示了此前未被识别的谐振腔与JPA(约瑟夫森参量放大器)之间的相互作用,同时让人们更深入地理解了本次取数运行的轴子搜索分析中所用系统噪声温度的系统不确定性。最后,测量结果与详细模型之间的一致性为ADMX及其他轴子晕镜未来实现更低噪声温度的改进方向提供了参考。

英文摘要:

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Due to the weak coupling of axions to photons however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra low-noise electronics. In this paper we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280~MHz taken during ADMX's most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and JPA, as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑