Sensitivity of a closed dielectric haloscope to axion dark matter
Max-Planck-Institut für Physik(马克斯·普朗克物理研究所);Deutsches Elektronen-Synchrotron DESY(德国电子同步辐射中心);RWTH Aachen University(亚琛工业大学);Aix Marseille Univ, CNRS/IN2P3, CPPM(艾克斯-马赛大学,法国国家科学研究中心/欧洲核子研究组织粒子物理实验室);Universität Hamburg(汉堡大学);Max-Planck-Institut für Radioastronomie(马克斯·普朗克射电天文研究所);Université Paris-Saclay, CNRS/IN2P3, IJCLab(巴黎萨克雷大学,法国国家科学研究中心/欧洲核子研究组织伊夫林-约瑟夫·沙尔实验室);Eberhard Karls Universität Tübingen(蒂宾根大学);Fermi National Accelerator Laboratory(费米国家加速器实验室)
A. Ivanov, D. Leppla-Weber, B. Ary dos Santos Garcia, D. Bergermann, H. Byun, A. Caldwell, V. Dabhi, C. Diaconu, J. Diehl, G. Dvali, B. Döbrich, J. Egge, E. Gar… 展开作者
A. Ivanov, D. Leppla-Weber, B. Ary dos Santos Garcia, D. Bergermann, H. Byun, A. Caldwell, V. Dabhi, C. Diaconu, J. Diehl, G. Dvali, B. Döbrich, J. Egge, E. Garutti, S. Heyminck, T. Houdy, F. Hubaut, J. Jochum, A. Kazemipour, Y. Kermaidic, S. Knirck, M. Kramer, D. Kreikemeyer-Lorenzo, C. Krieger, C. Lee, X. Li, A. Lindner, B. Majorovits, J. Maldonado, A. Martini, A. Miyazaki, E. Öz, P. Pralavorio, G. Raffelt, J. Redondo, A. Ringwald, J. Schaffran, A. Schmidt, L. Stankewitz, F. Steffen, C. Strandhagen, I. Usherov, H. Wang, G. Wieching
我们提出了一种方法,用于确定闭合介质磁强计对轴子暗物质的灵敏度。介质磁强计旨在通过使用介质盘堆叠和镜面来增强外部磁场中的轴子-光子转换,以探测理论上具有约26μeV至500μeV质量范围的轴子质量。其转换体积几乎与轴子质量无关,因此更倾向于大规模设计以提高灵敏度。大体积导致模拟计算成本高且耗时。本文提出了一种简单的模型,可用于在最小计算资源下确定实验的灵敏度。该模型能够描述闭合介质磁强计的电磁响应,考虑了实际几何不完美以及接收系统引入的噪声。该模型应用于在CERN的1.6T Morpurgo磁铁中进行的MAGNETIZED DISK AND MIRROR AXION EXPERIMENT(MADMAX)原型数据。这项工作奠定了使用介质磁强计进行首次轴子暗物质搜索的基础,并为未来使用MADMAX进行暗物质搜索提供了基础。
英文摘要:
We present a method to determine the sensitivity of a closed dielectric haloscope to axion dark matter. Dielectric haloscopes aim to probe the theoretically well-motivated axion mass range of ~26 $\mathrmμ$eV to ~500 $\mathrmμ$eV by utilizing a stack of dielectric disks and a mirror to enhance the axion-photon conversion within an external magnetic field. Their conversion volume is nearly axion-mass independent, thereby favoring large-scale designs to increase sensitivity. The large volume causes simulations to be computationally expensive and time-consuming. This paper presents a simple model that can be used to determine the sensitivity of the experiment with minimal computational resources. The model is able to describe the electromagnetic response of a closed dielectric haloscope, accounting for realistic geometric imperfections, as well as the noise introduced by the receiver system. It is applied to data taken with a MAgnetized Disk and Mirror Axion Experiment (MADMAX) prototype within the 1.6 T Morpurgo magnet at CERN. This work underpins the first axion dark matter search using a dielectric haloscope and provides the foundation for future dark matter searches with MADMAX.
Impact of the superconductors properties on the measurement sensitivity of resonant-based axion detectors
轴子,理论上解决强CP问题的假设粒子,目前被认为是冷暗物质组分的强候选者。基于共振的轴子探测器的信号功率,称为haloscopes,与它们的品质因数$Q$成正比。在本文中,使用超导体的性能的Haloscope的影响进行了研究,通过评估可获得的$Q$。特别地,从测量的涡旋运动复电阻率和这些材料的屏蔽长度开始,在感兴趣的频率、磁场和温度范围内计算NbTi、Nb $_3$ Sn、YBa $_2$ Cu $_3$ O $_{7-δ}$和FeSe $_{0.5}$ Te $_{0.5}$的表面电阻$R_s$。从$R_s$的品质因数$Q$的圆柱形晕镜与铜圆锥形基地和cylindrical侧壁,与TM $_{010}$模式下工作,进行评估和使用不同的材料的性能进行比较。YBa $_2$ Cu $_3$ O $_{7-δ}$和FeSe $_{0.5}$ Te $_{0.5}$都显示出相对于整个Cu腔提高几乎一个数量级的测量灵敏度,而NbTi显示出仅适用于较低的频率(<10 GHz)。Nb $_3$ Sn可以在整个感兴趣的光谱中给出中间改进。