electronCT -- An Imaging Technique Using Very-high Energy Electrons
Paul Schütze, Aenne Abel, Florian Burkart, L. Malinda S. de Silva, Hannes Dinter, Kevin Dojan, Adrian Herkert, Sonja Jaster-Merz, Max Joseph Kellermeier, Willi … 展开作者
Paul Schütze, Aenne Abel, Florian Burkart, L. Malinda S. de Silva, Hannes Dinter, Kevin Dojan, Adrian Herkert, Sonja Jaster-Merz, Max Joseph Kellermeier, Willi Kuropka, Frank Mayet, Sara Ruiz Daza, Simon Spannagel, Thomas Vinatier, Håkan Wennlöf
The electronCT technique is an imaging method based on the multiple Coulomb scattering of relativistic electrons and has potential applications in medical and industrial imaging. It utilizes a pencil beam of electrons in the very high energy electron (VHEE, 50-250 MeV) range and a single detection layer for the determination of the beam profile. The technique constitutes a projectional, two-dimensional imaging method and thus also qualifies for the tomographic reconstruction of samples. Given the simplicity of the technical setup and its location behind the sample, the electronCT technique has potential synergies with VHEE radiotherapy, making use of the same electron source for both treatment and diagnostics and thus being a candidate for in-situ imaging and patient localization. At the same time, several technical challenges arise from the measurement technique when applied for the imaging of living beings. Measurements performed at the ARES linear particle accelerator at an electron energy of 155 MeV using a mouse phantom and a Timepix3 silicon pixel detector assembly demonstrate the feasibility of this technique. Both projectional and tomographic reconstructions are presented and the potential and limits of the technology are discussed.
A compact design for velocity-map imaging energetic electrons and ions
我们提出了一个紧凑的设计,用于高能电子和离子的速度图成像光谱仪。Eppink和Parker的标准几何[A. T. J. B. Eppink和D. H.帕克,Rev. Sci.仪器68,3477(1997)]仅通过两个延伸电极来增强,以便实现附加的单透镜。以这种方式,对于7 kV的最大电极电压,我们通过实验证明了能量高达65 eV的电子的成像。模拟结果表明,当使用直径分别为42和78 mm的位置敏感探测器时,对于<20 kV的电极电压,可以实现<270和<1,200 eV的能量接受度以及dE / E <5%的能量分辨率。
Three-dimensional recoil-electron reconstruction using combined optical imaging and waveform readout for electron-tracking Compton cameras
National Institute of Advanced Industrial Science and Technology (AIST), National Metrology Institute of Japan (NMIJ)(国家产业技术综合研究所(AIST),日本国家计量院(NMIJ));Graduate School of Natural Science and Technology, Kanazawa University(金泽大学自然科学技术研究学院);Institute for Cosmic Ray Research, University of Tokyo(东京大学宇宙线研究所);Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency(日本宇宙航空研究开发机构宇宙科学研究所)