arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2408.15547astro-ph.CO
收藏

类星体X射线与紫外光度关系的红移演化:来自SNe Ia的校准结果

Redshift evolution of the X-ray and UV luminosity relation of quasars: calibrated results from SNe Ia

Xiaolei Li, Ryan E. Keeley, Arman Shafieloo

AI总结:

本研究利用SNe Ia重构的距离-红移关系校准类星体标准烛光,发现高、低红移类星体样本的校准参数存在约4σ不一致性,进而提出并验证了参数化的红移演化模型,使样本在1σ水平上达成一致。

摘要:

如果类星体的紫外和X射线光度之间的关系能够被准确校准,类星体就可以作为标准烛光。此前,我们开发了一种与模型无关的方法,利用高斯过程回归从z<2的Ia型超新星重构的距离-红移关系来校准类星体标准烛光。有趣的是,我们发现校准后的类星体标准烛光数据集在z>2的红移处偏好偏离ΛCDM模型。对这些发现的一种解释是,类星体紫外-X射线光度关系的校准参数随红移演化。为了以与模型无关的方式测试类星体校准的红移依赖性,我们将红移与Pantheon+ Ia型超新星汇编的红移覆盖范围重叠的类星体样本分为两个子样本:低红移类星体子样本和高红移类星体子样本。我们目前的结果表明,如果不考虑类星体关系的演化,从高红移类星体子样本和低红移子样本推断出的类星体参数之间存在约4σ的不一致性。这种不一致性表明有必要考虑类星体紫外和X射线光度之间关系的红移演化。然后,我们通过γ(z) = γ0+γ1(1+z)和β(z)=β0+β1(1+z)测试了类星体校准参数红移演化的显式参数化。将这种依赖于红移的校准关系与从Pantheon+超新星汇编重构的距离-红移关系相结合,我们发现高红移子样本和低红移子样本在1σ水平上变得一致,这意味着γ(z)和β(z)的参数化形式能很好地描述类星体校准参数的演化。

英文摘要:

Quasars could serve as standard candles if the relation between their ultraviolet and X-ray luminosities can be accurately calibrated. Previously, we developed a model-independent method to calibrate quasar standard candles using the distances-redshift relation reconstructed from Type Ia supernova at z<2 using Gaussian process regression. Interestingly, we found that the calibrated quasar standard candle dataset preferred a deviation from $Λ$CDM at redshifts above z>2. One interpretation of these findings is that the calibration parameters of the quasar UV-X-ray luminosity relationship evolves with redshift. In order to test the redshift dependence of the quasar calibration in a model-independent manner, we divided the quasar sample whose redshift overlap with the redshift coverage of Pantheon+ Type Ia supernova compilation into two sub-samples: a low-redshift quasar sub-sample and a high-redshift quasar sub-sample. Our present results show that there is about a 4$σ$ inconsistency between the quasar parameters inferred from the high-redshift quasar sub-sample and from the low-redshift sub-sample if no evolution of the quasar relation is considered. This inconsistency suggests the necessity of considering redshift evolution for the relationship between the quasars$'$ ultraviolet and X-ray luminosities. We then test an explicit parametrization of the redshift evolution of the quasar calibration parameters via $γ(z) = γ_0+γ_1(1+z)$ and $β(z)=β_0+β_1(1+z)$. Combining this redshift-dependent calibration relationship with the distance-redshift relationship reconstructed from Pantheon+ supernova compilation, we find the high-redshift sub-sample and low-redshift sub-sample become consistent at the 1$σ$ level, which means that the parameterized form of $γ(z)$ and $β(z)$ works well at describing the evolution of the quasar calibration parameters.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑