基于相机的痴呆症患者风险行为深度加权检测

Depth-Weighted Detection of Behaviours of Risk in People with Dementia using Cameras

KITE, Toronto Rehabilitation Institute, Toronto, ON, Canada, and Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada(KITE、多伦多康复研究所、多伦多,ON,加拿大,以及生物医学工程研究所、多伦多大学,多伦多,ON,加拿大);Computer Vision Lab, TU Wien(计算机视觉实验室、维也纳技术大学);KITE, Toronto Rehabilitation Institute, Toronto, ON, Canada(KITE、多伦多康复研究所、多伦多,ON,加拿大);Department of Psychiatry, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada(精神病学系、特默蒂医学学院、多伦多大学,多伦多,ON,加拿大);Daphne Cockwell School of Nursing, Toronto Metropolitan University, Toronto, ON, Canada(达芙妮·科克韦尔护理学院、多伦多 Metropolitan 大学,多伦多,ON,加拿大)

Pratik K. Mishra, Irene Ballester, Andrea Iaboni, Bing Ye, Kristine Newman, Alex Mihailidis, Shehroz S. Khan

AI总结:

针对痴呆症护理中的风险行为检测,提出深度加权损失函数以减少基于距离的误报,并在三个摄像头上取得最佳AUC 0.852、0.81和0.768,验证了方法的有效性。

摘要:

痴呆症的行为和心理症状,如躁动和攻击性,在养老护理环境中构成重大的健康和安全风险。许多护理设施在公共区域安装了视频摄像头进行数字监控,这可用于开发自动化的风险行为检测系统,该系统能提醒工作人员及时干预,防止情况升级。然而,我们先前研究中的一个挑战是,由于事件基于距离的重要性不同,导致误报的出现。为解决此问题,我们提出了一种新颖的深度加权损失函数,以强制对摄像头近处和远处发生的事件赋予同等重要性,从而有助于减少误报。我们进一步提出利用训练中的异常值来确定异常阈值。来自一个专门痴呆症单元中三个摄像头的九名痴呆症参与者的数据被用于训练。所提出的方法在三个摄像头上分别获得了最佳接收者操作特征曲线下面积性能0.852、0.81和0.768。针对所提出方法的各个组成部分以及帧大小和帧速率的影响进行了消融分析。还研究了所提出方法在跨摄像头、参与者特定和性别特定的风险行为检测中的性能。所提出的方法在减少误报方面表现合理。这激励了进一步研究,以使该系统更适合在护理设施中部署。

英文摘要:

The behavioural and psychological symptoms of dementia, such as agitation and aggression, present a significant health and safety risk in residential care settings. Many care facilities have video cameras in place for digital monitoring of public spaces, which can be leveraged to develop an automated behaviours of risk detection system that can alert the staff to enable timely intervention and prevent the situation from escalating. However, one of the challenges in our previous study was the presence of false alarms due to disparate importance of events based on distance. To address this issue, we proposed a novel depth-weighted loss to enforce equivalent importance to the events happening both near and far from the cameras; thus, helping to reduce false alarms. We further propose to utilize the training outliers to determine the anomaly threshold. The data from nine dementia participants across three cameras in a specialized dementia unit were used for training. The proposed approach obtained the best area under receiver operating characteristic curve performance of 0.852, 0.81 and 0.768, respectively, for the three cameras. Ablation analysis was conducted for the individual components of the proposed approach and effect of frame size and frame rate. The performance of the proposed approach was investigated for cross-camera, participant-specific and sex-specific behaviours of risk detection. The proposed approach performed reasonably well in reducing false alarms. This motivates further research to make the system more suitable for deployment in care facilities.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑