arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2408.06170eess.IVcs.CV
收藏

使用 Segment Anything Model 2 对 CT 扫描中的腹部器官进行零样本 3D 分割:将视频跟踪能力适配到 3D 医学成像

Zero-shot 3D Segmentation of Abdominal Organs in CT Scans Using Segment Anything Model 2: Adapting Video Tracking Capabilities for 3D Medical Imaging

The University of Tokyo(东京大学);The University of Tokyo Hospital(东京大学医学部附属医院);Jichi Medical University(自治医科大学);Chiba University(千叶大学)

Yosuke Yamagishi, Shouhei Hanaoka, Tomohiro Kikuchi, Takahiro Nakao, Yuta Nakamura, Yukihiro Nomura, Soichiro Miki, Takeharu Yoshikawa, Osamu Abe

AI总结:

本研究评估 SAM 2 零样本分割 CT 腹部器官的能力,发现其对大器官效果较好,且起始层面与负向提示显著影响性能。

摘要:

目的:评估 Segment Anything Model 2(SAM 2)在 CT 扫描中腹部器官 3D 分割的零样本性能,并研究提示设置对分割结果的影响。材料与方法:在这项回顾性研究中,我们使用来自八家机构的 TotalSegmentator CT 数据集子集,评估 SAM 2 分割八个腹部器官的能力。分割从每个器官的三个不同 z 坐标层面(尾侧、中部和颅侧层面)启动。采用 Dice 相似系数(DSC)衡量性能。我们还分析了“负向提示”(即在分割过程中明确排除某些区域)对准确性的影响。结果:共评估 123 例患者(平均年龄 60.7 ± 15.5 岁;63 名男性,60 名女性)。作为一种零样本方法,边界清晰的较大器官表现出较高的分割性能,平均 DSC 如下:肝脏 0.821 ± 0.192,右肾 0.862 ± 0.212,左肾 0.870 ± 0.154,脾脏 0.891 ± 0.131。较小器官性能较低:胆囊 0.531 ± 0.291,胰腺 0.361 ± 0.197,肾上腺右侧 0.203 ± 0.222、左侧 0.308 ± 0.234。分割起始层面和负向提示的使用显著影响结果。从输入中移除负向提示后,六个器官的 DSC 显著下降。结论:SAM 2 在 CT 扫描中分割某些腹部器官(尤其是较大器官)方面展现出有前景的零样本性能。性能受到输入负向提示和起始层面选择的显著影响,凸显了优化这些因素的重要性。

英文摘要:

Objectives: To evaluate the zero-shot performance of Segment Anything Model 2 (SAM 2) in 3D segmentation of abdominal organs in CT scans, and to investigate the effects of prompt settings on segmentation results. Materials and Methods: In this retrospective study, we used a subset of the TotalSegmentator CT dataset from eight institutions to assess SAM 2's ability to segment eight abdominal organs. Segmentation was initiated from three different z-coordinate levels (caudal, mid, and cranial levels) of each organ. Performance was measured using the Dice similarity coefficient (DSC). We also analyzed the impact of "negative prompts," which explicitly exclude certain regions from the segmentation process, on accuracy. Results: 123 patients (mean age, 60.7 \pm 15.5 years; 63 men, 60 women) were evaluated. As a zero-shot approach, larger organs with clear boundaries demonstrated high segmentation performance, with mean DSCs as follows: liver 0.821 \pm 0.192, right kidney 0.862 \pm 0.212, left kidney 0.870 \pm 0.154, and spleen 0.891 \pm 0.131. Smaller organs showed lower performance: gallbladder 0.531 \pm 0.291, pancreas 0.361 \pm 0.197, and adrenal glands, right 0.203 \pm 0.222, left 0.308 \pm 0.234. The initial slice for segmentation and the use of negative prompts significantly influenced the results. By removing negative prompts from the input, the DSCs significantly decreased for six organs. Conclusion: SAM 2 demonstrated promising zero-shot performance in segmenting certain abdominal organs in CT scans, particularly larger organs. Performance was significantly influenced by input negative prompts and initial slice selection, highlighting the importance of optimizing these factors.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑