失超加热器中的霍尔效应、磁阻和电流分布
Hall Effect, Magnetoresistance, and Current Distribution in Quench Heaters
AI总结:
本文通过数值模拟研究了磁阻、霍尔效应和几何形状对失超加热器电流分布的影响,发现磁阻作用微小,霍尔效应在多数情况下不构成问题,但设计时需考虑几何形状并采取措施均衡电流密度。
摘要:
失超加热器通常是保护超导加速器磁体在失超期间安全的重要组成部分。其目的是尽快将失超扩散到整个线圈中。它们位于强磁场区域,因此容易受到磁阻现象和霍尔效应的影响。这些影响可能导致电流在加热器中分布不均,从而导致加热不均匀。这会降低加热器的有效性,甚至可能因局部过热而危及加热器。此外,加热器本身的几何形状也可能导致电流密度不均。在本文中,我们通过数值模拟研究了磁效应对失超加热器性能的重要性,以及是否应在设计中将其纳入考量。主要关注点在于霍尔效应,它被认为是失超加热器设计中最可能出现问题的根源。我们采用简单的唯象方法对霍尔效应进行建模,利用文献中的霍尔系数值。同时考虑了磁阻,并简要探讨了加热器几何形状对电流分布的影响。本研究的结论是,磁阻在失超加热器的功能中起着微不足道的作用。霍尔效应显然更具影响力,但在大多数情况下仍不应造成任何问题。设计阶段应考虑由加热器几何形状引起的电流分布问题,如有需要,应采取措施(例如在适当位置使用铜包层)来均衡电流密度。
英文摘要:
Quench heaters are often an essential part of protecting a superconducting accelerator magnet during a quench. Their purpose is to spread the quench throughout the coil as quickly as possible. They are located in areas of high magnetic fields and are thus prone to magnetoresistive phenomena and the Hall effect. Such influences can cause currents to distribute unevenly in the heaters, which results in uneven heating. This can reduce the effectiveness of the heaters and even endanger them due to excessive local heating. Also, the heater geometry itself can be the cause of uneven current density. In this paper we investigate by numerical simulations the importance of the magnetic effects on quench heater performance and whether they should be taken into account in the design. The main interest is in the Hall effect, which was perceived as the most likely source of trouble for the design of quench heaters. We use a simple phenomenological approach for modeling the Hall effect, utilizing values from the literature for the Hall coefficients. Magnetoresistance is also considered and the impact of heater geometry on current distributions is briefly visited. The conclusion of this research is that magnetoresistance plays an insignificant role in the functioning of quench heaters. The Hall effect can clearly be more influential, but nevertheless should not pose any problems in most cases. Current distributions due to heater geometry should be take into consideration in the design phase and, if needed, take measures to equalize the current density by using, for example, copper cladding in appropriate locations.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。