临界电流分布对HTS饼式线圈运行、失超检测与保护的影响
Influence of Critical Current Distribution on Operation, Quench Detection and Protection of HTS Pancake Coils
AI总结:
本文通过三维电磁-热耦合仿真,研究HTS饼式线圈中临界电流分布缺陷对热失控和失超检测的影响,发现局部缺陷与失超加热器场景对检测要求差异显著。
摘要:
高温超导(HTS)涂层导体(CC)常被绕制成饼式线圈,匝间带有电绝缘。铜端子用于电流注入和传导冷却。由于制造工艺,CC沿长度方向的临界电流存在固有变化。这种变化会导致不均匀的热产生,特别是当线圈在标称临界电流的高比例下运行或存在大的临界电流缺陷时。由冷却与加热平衡产生的温度分布,结合磁场和临界电流分布,决定了是否发生热失控。准确预测在传导冷却运行期间可容忍的临界电流缺陷水平是困难的,需要三维耦合电磁和热仿真。本文介绍了使用CERN在STEAM框架内开发的开源有限元失超模拟器(FiQuS)工具进行的仿真结果。三维耦合磁动力-热仿真基于H-phi公式,采用薄壳近似、CC均质化和传导冷却。临界电流(Ic)沿CC长度变化。研究了沿CC长度指定为Ic减小的单个缺陷对线圈达到并维持运行条件能力的影响。从缺陷位置的角度分析了导致热失控的Ic和缺陷长度。此外,还研究了一个带有失超加热器的经典一维场景。在可用于失超检测的电压信号方面,对局部缺陷和加热器两种情况进行了比较。这些情况对失超检测提出了非常不同的要求,并讨论了其影响。
英文摘要:
High-temperature superconductor (HTS) coated conductors (CC) are often wound into pancake coils with electrical insulation in-between the turns. The copper terminals are used for current injection and conduction cooling. An inherent variation of the critical current along the CC length results from its manufacturing process. This variation causes non-uniform heat generation, particularly when the coil is operated at a high fraction of the nominal critical current or when large critical current defects are present. The temperature distribution resulting from the balance between cooling and heating, in combination with the magnetic field and critical current distributions, determines whether a thermal runaway occurs. Accurately predicting the level of critical current defects that can be tolerated during conduction-cooled operation is difficult and requires a 3D coupled electromagnetic and thermal simulation. This paper presents the results of simulations that are performed with the open-source Finite Element Quench Simulator (FiQuS) tool developed at CERN as part of the STEAM framework. The 3D coupled magnetodynamic-thermal simulations are based on the H-phi formulation and use thin shell approximations, a CC homogenization and conduction-cooling. The critical current (Ic) is varied along the CC length. The effect of a single defect specified as a reduction of Ic along the CC length is investigated in terms of the coil's ability to reach and maintain the operating conditions. The Ic and length of the defect that results in a thermal runaway are analyzed in terms of defect location. In addition, a classical 1D scenario with a quench heater is studied. Both the local defect and the heater cases are compared in terms of the voltage signal available for quench detection. These cases result in very different requirements for quench detection, and their implications are discussed.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。