Models and experimental results from the wide aperture Nb-Ti magnets for the LHC upgrade
G. Kirby, B. Auchmann, M. Bajko, M. Charrondiere, N. Bourcey, V. I. Datskov, P. Fessia, J. Feuvrier, P. Galbraith, A. Garcia Tabares, J. Garcia-Perez, P. Granie… 展开作者
G. Kirby, B. Auchmann, M. Bajko, M. Charrondiere, N. Bourcey, V. I. Datskov, P. Fessia, J. Feuvrier, P. Galbraith, A. Garcia Tabares, J. Garcia-Perez, P. Granieri, P. Hagen, C. Lorin, J. C. Perez, S. Russenschuck, T. Sahner, M. Segreti, E. Todesco, G. Willering
备注:
8 pages, Contribution to WAMSDO 2013: Workshop on Accelerator Magnet, Superconductor, Design and Optimization; 15 - 16 Jan 2013, CERN, Geneva, Switzerland
MQXC is a Nb-Ti quadrupole designed to meet the accelerator quality requirements needed for the phase-1 LHC upgrade, now superseded by the high luminosity upgrade foreseen in 2021. The 2-m-long model magnet was tested at room temperature and 1.9 K. The technology developed for this magnet is relevant for other magnets currently under development for the high-luminosity upgrade, namely D1 (at KEK) and the large aperture twin quadrupole Q4 (at CEA). In this paper we present MQXC test results, some of the specialized heat extraction features, spot heaters, temperature sensor mounting and voltage tap development for the special open cable insulation. We look at some problem solving with noisy signals, give an overview of electrical testing, look at how we calculate the coil resistance during at quench and show that the heaters are not working We describe the quench signals and its timing, the development of the quench heaters and give an explanation of an Excel quench calculation and its comparison including the good agreement with the MQXC test results. We propose an improvement to the magnet circuit design to reduce voltage to ground values by factor 2. The program is then used to predict quench Hot-Spot and Voltages values for the D1 dipole and the Q4 quadrupole.
Operational aspects of the Main Injector large aperture quadrupole (WQB)
2006年夏天,费米实验室完成了一个为期两年的大孔径四极子(WQB)项目。技术司设计、制造和台架测试了9个WQB。其中7个安装在主喷油器中,另外2个作为备件。他们表现得很好。孔径的增加满足设计目标,对晶格的扰动是最小的。注射和提取区域的机器接受度从40 pi增加到60 pi mm-mrad。本文简要介绍了这些磁体的工作和性能。