arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2401.10633physics.med-ph
收藏

配备编码孔径准直器的紧凑型伽马相机轴向分辨率评估

Assessment of the Axial Resolution of a Compact Gamma Camera with Coded Aperture Collimator

Tobias Meißner, Laura Antonia Cerbone, Paolo Russo, Werner Nahm, Jürgen Hesser

AI总结:

本文评估配备 Timepix3 与秩31 MURA 掩模的紧凑型编码孔径伽马相机,比较 MURA Decoding 与3D-MLEM在近场点源深度估计中的轴向分辨率及计算性能。

摘要:

目的:配备编码孔径准直器的手持式伽马相机正被研究用于核医学术中成像。由于其高灵敏度以及三维成像的可能性,编码孔径是一种适用于淋巴结定位等应用的有前景的准直技术。我们评估了两种重建方法的轴向分辨率和计算性能。方法:搭建了一台实验性伽马相机,其由像素化半导体探测器 Timepix3 和秩为31的 MURA 掩模组成;该掩模是在0.11 mm厚的钨片中带有直径0.08 mm圆孔的结构。进行了一组测量,其中一个点状伽马源被居中放置在12至100 mm范围内的21个不同位置。对于每个源位置,在真实源位置附近以0.5 mm步长重建探测器图像,从而形成图像堆栈。轴向分辨率通过沿堆栈 z 轴的对比度噪声比(CNR)曲线的半高全宽(FWHM)进行评估。比较了两种重建方法:MURA Decoding 和三维最大似然期望最大化算法(3D-MLEM)。结果:尽管计算时间长4,400倍,3D-MLEM产生了更小的轴向 FWHM 和更高的 CNR。对于 MURA Decoding 和 3D-MLEM,轴向分辨率分别从12 mm处的5.3 mm和1.8 mm退化至100 mm处的42.2 mm和13.5 mm。结论:我们的结果表明,编码孔径能够在近场中实现单个点状源的深度估计。在此,3D-MLEM提供了更好的轴向分辨率,但在计算上比 MURA Decoding 慢得多,而后者的重建时间与实时成像兼容。

英文摘要:

Purpose: Handheld gamma cameras with coded aperture collimators are under investigation for intraoperative imaging in nuclear medicine. Coded apertures are a promising collimation technique for applications such as lymph node localization due to their high sensitivity and the possibility of 3D imaging. We evaluated the axial resolution and computational performance of two reconstruction methods. Methods: An experimental gamma camera was set up consisting of the pixelated semiconductor detector Timepix3 and MURA mask of rank $31$ with round holes of $0.08$mm in diameter in a $0.11$mm thick Tungsten sheet. A set of measurements was taken where a point-like gamma source was placed centrally at $21$ different positions within the range of $12$ to $100$mm. For each source position, the detector image was reconstructed in $0.5$mm steps around the true source position, resulting in an image stack. The axial resolution was assessed by the full width at half maximum (FWHM) of the contrast-to-noise ratio (CNR) profile along the z-axis of the stack. Two reconstruction methods were compared: MURA Decoding and a 3D maximum likelihood expectation maximization algorithm (3D-MLEM). Results: While taking $4{,}400$ times longer in computation, 3D-MLEM yielded a smaller axial FWHM and a higher CNR. The axial resolution degraded from $5.3$mm and $1.8$mm at $12$mm to $42.2$mm and $13.5$mm at $100$mm for MURA Decoding and 3D-MLEM respectively. Conclusion: Our results show that the coded aperture enables the depth estimation of single point-like sources in the near field. Here, 3D-MLEM offered a better axial resolution but was computationally much slower than MURA Decoding, whose reconstruction time is compatible with real-time imaging.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑