arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2401.01747physics.ins-det
收藏

在电磁簇射最大值处能量范围 25 GeV $\leq$ E $\leq$ 150 GeV 下超紧凑采样量能器(RADiCAL)模块的时间和能量分辨率研究

Study of time and energy resolution of an ultra-compact sampling calorimeter (RADiCAL) module at EM shower maximum over the energy range 25 GeV $\leq$ E $\leq$ 150 GeV

Carlos Perez-Lara, James Wetzel, Ugur Akgun, Thomas Anderson, Thomas Barbera, Dylan Blend, Kerem Cankocak, Salim Cerci, Nehal Chigurupati, Bradley Cox, Paul Deb… 展开作者

Carlos Perez-Lara, James Wetzel, Ugur Akgun, Thomas Anderson, Thomas Barbera, Dylan Blend, Kerem Cankocak, Salim Cerci, Nehal Chigurupati, Bradley Cox, Paul Debbins, Max Dubnowski, Buse Duran, Gizem Gul Dincer, Selbi Hatipoglu, Ilknur Hos, Bora Isildak, Colin Jessop, Ohannes Kamer Koseyan, Ayben Karasu Uysal, Reyhan Kurt, Berkan Kaynak, Alexander Ledovskoy, Alexi Mestvirishvili, Yasar Onel, Suat Ozkorucuklu, Aldo Penzo, Onur Potok, Daniel Ruggiero, Randal Ruchti, Deniz Sunar Cerci, Ali Tosun, Mark Vigneault, Yuyi Wan, Mitchell Wayne, Taylan Yetkin, Liyuan Zhang, Renyuan Zhu, Caglar Zorbilmez

AI总结:

RADiCAL合作组研发了基于闪烁与波长移位技术的超紧凑采样量能器模块,并在CERN的H2电子束下测试,证明其在150 GeV时时间分辨率达27 ps。

摘要:

RADiCAL 合作组正在开展高性能电磁(EM)量能器的研发,以应对未来对撞机实验中预期在高峰值亮度/或高辐照条件下(FCC-ee、FCC-hh 以及固定靶和前向物理环境)面临的挑战。目前正在开发一种基于闪烁和波长移位(WLS)技术以及光电传感器(包括 SiPM 和类 SiPM 技术)的采样量能器方法,称为 RADiCAL 模块。本文讨论的模块由非常致密的钨(W)吸收体和闪烁晶体(LYSO:Ce)板交替层组成,组装深度为 25 $X_0$。EM 簇射在电磁簇射最大值区域产生的闪烁信号,通过贯穿模块全长的石英毛细管传输到位于模块上游和下游端的 SiPM。毛细管内含有 DSB1 有机塑料 WLS 灯丝,这些灯丝放置在簇射能量沉积最大的簇射最大值区域内,而在其他位置则与石英棒熔接。来自该空间局部化簇射最大值区域的波长移位光随后被传输到光电传感器。本文展示了使用 CERN 的 H2 电子束对 RADiCAL 模块在 25 GeV $\leq$ E $\leq$ 150 GeV 能量范围内进行时间分辨率初步测量的结果。数据表明,时间分辨率随能量变化的依赖关系遵循以下函数形式:$σ_{t} = a/\sqrt{E} \oplus b$,其中 a = 256 $\sqrt{GeV}$~ps,b = 17.5 ps。在目前记录数据的最高电子束能量(150 GeV)下,测得的时间分辨率为 $σ_{t}$ = 27 ps。

英文摘要:

The RADiCAL Collaboration is conducting R\&D on high performance electromagnetic (EM) calorimetry to address the challenges expected in future collider experiments under conditions of high luminosity and/or high irradiation (FCC-ee, FCC-hh and fixed target and forward physics environments). Under development is a sampling calorimeter approach, known as RADiCAL modules, based on scintillation and wavelength-shifting (WLS) technologies and photosensor, including SiPM and SiPM-like technology. The modules discussed herein consist of alternating layers of very dense (W) absorber and scintillating crystal (LYSO:Ce) plates, assembled to a depth of 25 $X_0$. The scintillation signals produced by the EM showers in the region of EM shower maximum (shower max) are transmitted to SiPM located at the upstream and downstream ends of the modules via quartz capillaries which penetrate the full length of the module. The capillaries contain DSB1 organic plastic WLS filaments positioned within the region of shower max, where the shower energy deposition is greatest, and fused with quartz rod elsewhere. The wavelength shifted light from this spatially-localized shower max region is then propagated to the photosensors. This paper presents the results of an initial measurement of the time resolution of a RADiCAL module over the energy range 25 GeV $\leq$ E $\leq$ 150 GeV using the H2 electron beam at CERN. The data indicate an energy dependence of the time resolution that follows the functional form: $σ_{t} = a/\sqrt{E} \oplus b$, where a = 256 $\sqrt{GeV}$~ps and b = 17.5 ps. The time resolution measured at the highest electron beam energy for which data was currently recorded (150 GeV) was found to be $σ_{t}$ = 27 ps.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑