ALICE前向量能器电磁和强子原型段性能

Performance of the electromagnetic and hadronic prototype segments of the ALICE Forward Calorimeter

M. Aehle, J. Alme, C. Arata, I. Arsene, I. Bearden, T. Bodova, V. Borshchov, O. Bourrion, M. Bregant, A. van den Brink, V. Buchakchiev, A. Buhl, T. Chujo, L. Du… 展开作者

M. Aehle, J. Alme, C. Arata, I. Arsene, I. Bearden, T. Bodova, V. Borshchov, O. Bourrion, M. Bregant, A. van den Brink, V. Buchakchiev, A. Buhl, T. Chujo, L. Dufke, V. Eikeland, M. Fasel, N. Gauger, A. Gautam, A. Ghimouz, Y. Goto, R. Guernane, T. Hachiya, H. Hassan, L. He, H. Helstrup, L. Huhta, M. Inaba, T. Inukai, T. Isidori, F. Jonas, T. Kawaguchi, R. Keidel, M. Kim, V. Kozhuharov, T. Kumaoka, L. Kusch, C. Loizides, Y. Melikyan, Y. Miake, N. Minafra, J. Nystrand, N. Novitzky, T. Øekland, K. Oyama, H. Park, J. Park, I. Pascal, T. Peitzmann, M. Protsenko, S. S. Räsänen, F. Rarbi, M. Rauch, A. Rehman, M. Richter, D. Röhrich, K. Røed, A. Rusu, H. Rytkönen, S. Sakai, K. Sato, A. Schilling, S. Shimizu, M. Shimomura, R. Simeonov, E. Solheim, T. Sugitate, G. Tambave, D. Tapia Takaki, D. Tourres, I. Tymchuk, J. Yi, Z. Yin, K. Ullaland, S. Yang, T. Yokoo, D. Zhou, S. Zillien

AI总结:

本文报告了ALICE前向量能器全尺寸原型的性能,包括电磁段和强子段,验证了其能量分辨率与线性度,并指出强子段与模拟的差异需进一步研究。

摘要:

我们展示了ALICE前向量能器(FoCal)全尺寸原型的性能。该探测器由一个具有纵向和横向分段(FoCal-E)的硅-钨电磁取样量能器(约20$X_0$)和一个强子铜-闪烁光纤量能器(FoCal-H,约5$λ_{\ m int}$)组成。数据于2021年至2023年间在CERN PS和SPS束流线上获取,使用能量高达350(300)GeV的强子(电子)束。对于FoCal-E,我们报告了其对所有pad层最小电离粒子响应的全面分析。电磁簇射的纵向簇射轮廓通过1$X_0$的分层分段进行测量。作为最终探测器在电磁簇射中性能的预测,我们展示了在全能量范围内的线性度,并表明能量分辨率满足物理需求的要求。此外,通过量化横向簇射宽度,研究了两簇射事件分离的性能。对于FoCal-H,我们报告了在60至350 GeV之间强子束响应的详细分析。结果与使用测试束装置Geant4模型获得的模拟进行了比较,特别是对于FoCal-E,与数据吻合良好。FoCal-E的能量分辨率在能量大于100 GeV时低于3%。FoCal-H对强子束的响应被发现是线性的,尽管存在一个显著的截距,约为模拟中的2倍。其分辨率非高斯且通常大于模拟,使用FWHM进行量化,从100 GeV时的约16%下降到350 GeV时的约11%。与模拟的差异在低强子能量时尤为明显,需要进一步研究。

英文摘要:

We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$λ_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS and SPS beam lines with hadron (electron) beams up to energies of 350 (300) GeV. Regarding FoCal-E, we report a comprehensive analysis of its response to minimum ionizing particles across all pad layers. The longitudinal shower profile of electromagnetic showers is measured with a layer-wise segmentation of 1$X_0$. As a projection to the performance of the final detector in electromagnetic showers, we demonstrate linearity in the full energy range, and show that the energy resolution fulfills the requirements for the physics needs. Additionally, the performance to separate two-showers events was studied by quantifying the transverse shower width. Regarding FoCal-H, we report a detailed analysis of the response to hadron beams between 60 and 350 GeV. The results are compared to simulations obtained with a Geant4 model of the test beam setup, which in particular for FoCal-E are in good agreement with the data. The energy resolution of FoCal-E was found to be lower than 3% at energies larger than 100 GeV. The response of FoCal-H to hadron beams was found to be linear, albeit with a significant intercept that is about factor 2 larger than in simulations. Its resolution, which is non-Gaussian and generally larger than in simulations, was quantified using the FWHM, and decreases from about 16% at 100 GeV to about 11% at 350 GeV. The discrepancy to simulations, which is particularly evident at low hadron energies, needs to be further investigated.