arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2310.06142quant-ph
收藏

基于时间反转辅助比特的吸收参数计量的量子优势

Quantum advantage of time-reversed ancilla-based metrology of absorption parameters

Jiaxuan Wang, Ruynet. L. de Matos Filho, Girish S. Agarwal, Luiz Davidovich

AI总结:

针对样品吸收损耗估计,论文提出利用双模压缩态的探针—辅助比特联合光子计数及双光学参量放大器时间反转方案,实现Fock态级量子精度,并证明其抗相位噪声、解纠缠和中等损耗。

摘要:

定义开放系统动力学的参数的量子估计,可通过使用与探针纠缠但不经历该动力学的辅助比特来增强。本文考虑一个重要问题:估计样品对光的透射率,其中损耗由吸收和散射引起。通过确定量子 Fisher 信息,我们证明辅助比特策略在单模估计中可达到最佳可能精度,即 Fock 态输入所获得的精度;这是通过对探针和辅助比特进行联合光子计数实现的,二者是由光学参量放大器产生的双模压缩态的两个模式。该方案克服了产生和探测高光子数 Fock 态的挑战,并且对附加噪声具有很强的鲁棒性:我们证明它对相位噪声免疫,而且即使输入态变为解纠缠状态,精度也不会改变。此外,在输入光束存在中等光子损耗时,量子增益仍然存在。我们还讨论了联合光子计数的一种替代方案,它可利用现有技术直接实现,并且即使在探测样品之前输入光束存在中等光子损耗,在弱吸收情况下也能逼近量子 Fisher 信息结果:这是一种时间反转程序,将样品置于两个光学参量放大器之间,第二个放大器撤销第一个放大器产生的压缩。损耗参数的估计精度由出射总光子数的平均值及其方差得到。在这两个程序中,探针的状态和探测程序都与参数值无关。

英文摘要:

Quantum estimation of parameters defining open-system dynamics may be enhanced by using ancillas that are entangled with the probe but are not submitted to the dynamics. Here we consider the important problem of estimation of transmission of light by a sample, with losses due to absorption and scattering. We show, through the determination of the quantum Fisher information, that the ancilla strategy leads to the best possible precision in single-mode estimation, the one obtained for a Fock state input, through joint photon-counting of probe and ancilla, which are modes of a bimodal squeezed state produced by an optical parametric amplifier. This proposal overcomes the challenge of producing and detecting high photon-number Fock states, and it is quite robust against additional noise: we show that it is immune to phase noise and the precision does not change if the incoming state gets disentangled. Furthermore, the quantum gain is still present under moderate photon losses of the input beams. We also discuss an alternative to joint photon counting, which is readily implementable with present technology, and approaches the quantum Fisher information result for weak absorption, even with moderate photons losses of the input beams before the sample is probed: a time-reversal procedure, placing the sample between two optical parametric amplifiers, with the second undoing the squeezing produced by the first one. The precision of estimation of the loss parameter is obtained from the average outgoing total photon number and its variance. In both procedures, the state of the probe and the detection procedure are independent of the value of the parameter.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑