arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2308.06230hep-ex
收藏

正缪子反常磁矩测量至0.20 ppm

Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

D. P. Aguillard, T. Albahri, D. Allspach, A. Anisenkov, K. Badgley, S. Baeßler, I. Bailey, L. Bailey, V. A. Baranov, E. Barlas-Yucel, T. Barrett, E. Barzi, F. B… 展开作者

D. P. Aguillard, T. Albahri, D. Allspach, A. Anisenkov, K. Badgley, S. Baeßler, I. Bailey, L. Bailey, V. A. Baranov, E. Barlas-Yucel, T. Barrett, E. Barzi, F. Bedeschi, M. Berz, M. Bhattacharya, H. P. Binney, P. Bloom, J. Bono, E. Bottalico, T. Bowcock, S. Braun, M. Bressler, G. Cantatore, R. M. Carey, B. C. K. Casey, D. Cauz, R. Chakraborty, A. Chapelain, S. Chappa, S. Charity, C. Chen, M. Cheng, R. Chislett, Z. Chu, T. E. Chupp, C. Claessens, M. E. Convery, S. Corrodi, L. Cotrozzi, J. D. Crnkovic, S. Dabagov, P. T. Debevec, S. Di Falco, G. Di Sciascio, B. Drendel, A. Driutti, V. N. Duginov, M. Eads, A. Edmonds, J. Esquivel, M. Farooq, R. Fatemi, C. Ferrari, M. Fertl, A. T. Fienberg, A. Fioretti, D. Flay, S. B. Foster, H. Friedsam, N. S. Froemming, C. Gabbanini, I. Gaines, M. D. Galati, S. Ganguly, A. Garcia, J. George, L. K. Gibbons, A. Gioiosa, K. L. Giovanetti, P. Girotti, W. Gohn, L. Goodenough, T. Gorringe, J. Grange, S. Grant, F. Gray, S. Haciomeroglu, T. Halewood-Leagas, D. Hampai, F. Han, J. Hempstead, D. W. Hertzog, G. Hesketh, E. Hess, A. Hibbert, Z. Hodge, K. W. Hong, R. Hong, T. Hu, Y. Hu, M. Iacovacci, M. Incagli, P. Kammel, M. Kargiantoulakis, M. Karuza, J. Kaspar, D. Kawall, L. Kelton, A. Keshavarzi, D. S. Kessler, K. S. Khaw, Z. Khechadoorian, N. V. Khomutov, B. Kiburg, M. Kiburg, O. Kim, N. Kinnaird, E. Kraegeloh, V. A. Krylov, N. A. Kuchinskiy, K. R. Labe, J. LaBounty, M. Lancaster, S. Lee, B. Li, D. Li, L. Li, I. Logashenko, A. Lorente Campos, Z. Lu, A. Lucà, G. Lukicov, A. Lusiani, A. L. Lyon, B. MacCoy, R. Madrak, K. Makino, S. Mastroianni, J. P. Miller, S. Miozzi, B. Mitra, J. P. Morgan, W. M. Morse, J. Mott, A. Nath, J. K. Ng, H. Nguyen, Y. Oksuzian, Z. Omarov, R. Osofsky, S. Park, G. Pauletta, G. M. Piacentino, R. N. Pilato, K. T. Pitts, B. Plaster, D. Počanić, N. Pohlman, C. C. Polly, J. Price, B. Quinn, M. U. H. Qureshi, S. Ramachandran, E. Ramberg, R. Reimann, B. L. Roberts, D. L. Rubin, L. Santi, C. Schlesier, A. Schreckenberger, Y. K. Semertzidis, D. Shemyakin, M. Sorbara, J. Stapleton, D. Still, D. Stöckinger, C. Stoughton, D. Stratakis, H. E. Swanson, G. Sweetmore, D. A. Sweigart, M. J. Syphers, D. A. Tarazona, T. Teubner, A. E. Tewsley-Booth, V. Tishchenko, N. H. Tran, W. Turner, E. Valetov, D. Vasilkova, G. Venanzoni, V. P. Volnykh, T. Walton, A. Weisskopf, L. Welty-Rieger, P. Winter, Y. Wu, B. Yu, M. Yucel, Y. Zeng, C. Zhang

AI总结:

基于费米实验室缪子g-2实验2019-2020年数据,测量正缪子反常磁矩至0.20 ppm,结合2018年结果,新世界平均值精度提升2倍。

摘要:

我们提出了来自费米实验室缪子g-2实验的新测量结果,该结果基于2019年和2020年收集的数据,测量了正缪子磁异常$a_μ\(g_μ-2)/2$。我们分析了比2018年数据先前结果多4倍以上的缪子衰变正电子数。由于更好的运行条件、更稳定的束流以及提高了对缪子分布加权磁场$\ ildeω'_p$和考虑束流动力学效应修正后的异常进动频率$ω_a$的认识,系统误差降低了超过2倍。由$ω_a / \ ildeω'_p$比值,结合精确确定的外部参数,我们确定$a_μ= 116\,592\,057(25) \ imes 10^{-11}$(0.21 ppm)。将此结果与2018年数据的先前结果结合,我们得到$a_μ\ ext{(FNAL)} = 116\,592\,055(24) \ imes 10^{-11}$(0.20 ppm)。新的实验世界平均值为$a_μ(\ ext{Exp}) = 116\,592\,059(22)\ imes 10^{-11}$(0.19 ppm),这代表了精度提高了2倍。

英文摘要:

We present a new measurement of the positive muon magnetic anomaly, $a_μ\equiv (g_μ- 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, $\tildeω'^{}_p$, and of the anomalous precession frequency corrected for beam dynamics effects, $ω_a$. From the ratio $ω_a / \tildeω'^{}_p$, together with precisely determined external parameters, we determine $a_μ= 116\,592\,057(25) \times 10^{-11}$ (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain $a_μ\text{(FNAL)} = 116\,592\,055(24) \times 10^{-11}$ (0.20 ppm). The new experimental world average is $a_μ(\text{Exp}) = 116\,592\,059(22)\times 10^{-11}$ (0.19 ppm), which represents a factor of 2 improvement in precision.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑