arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2512.11486hep-exhep-ph
收藏

CANTON-μ提案:在中国高能重离子加速器设施(HIAF)上实现亚0.1ppm精度的下一代muon g-2测量

CANTON-$μ$ Proposal: A Next-Generation Muon $g-2$ Measurement at Sub-0.1 ppm Precision

University of Liverpool(利物浦大学);Advanced Energy Science and Technology Guangdong Laboratory(广东省先进能源科学与技术实验室);Institute of Modern Physics, CAS(中国科学院近代物理研究所);University of Washington(华盛顿大学);Zhejiang Lab(浙江实验室);School of Nuclear Science and Technology, University of Chinese Academy of Sciences(中国科学院大学核科学与技术学院);School of Physics and Astronomy, Shanghai Jiao Tong University(上海交通大学物理与天文学院);State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University(北京大学物理学院核物理与技术国家重点实验室)

Ce Zhang, Yu Xu, On Kim, Bingzhi Li, Zejia Lu, Saskia Charity, Guodong Shen, Liangwen Chen, Fedor Ignatov, Liang Li, Qiang Li, Xueheng Zhang, Zhiyu Sun

AI总结:

CANTON-μ项目利用HIAF的高能muon束流,旨在超越费米实验室精度,通过统计和系统误差控制达到0.1ppm和0.05ppm的测量精度,用于测试标准模型和探索新物理。

摘要:

我们提出了一项下一代高精度muon异常磁矩(muon g-2)测量项目,利用中国高能重离子加速器设施(HIAF)的高能muon束流。该项目名为CANTON-μ(Coherent Anomalous magNetic momenT ObservatioN with muon),是首个旨在超越费米实验室精度的muon g-2实验。它引入了基于HIAF高强度脉冲GeV量级muon束流的新方法,特别是针对负muon极性。本工作研究了HIAF处预期的muon束流强度,确定了实现0.13 ppm精度(第一阶段,与当前费米实验室精度相当)和0.05 ppm精度(第二阶段,通过HIAF升级)所需的统计范围和系统误差控制水平。这种精度使我们能够对标准模型进行严格测试,并对超出当前对撞机尺度的新物理敏感。同时,它还提供了在标准模型扩展的10^-24 GeV水平上对CPT对称性的独特敏感测试,比现有限制提高了超过一个数量级。

英文摘要:

We propose a next-generation precision measurement of the muon anomalous magnetic moment (muon g-2) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China. We refer to this proposed experimental programme as CANTON-$μ$ (Coherent Anomalous magNetic momenT ObservatioN with muon). HIAF's intense, pulsed GeV-scale muon beams, particularly for negative muons, provide a promising basis for this programme. Building on two previously proposed storage-ring concepts, this work develops HIAF-specific experimental schemes that relax the conventional magic-momentum constraint and allow greater flexibility in the choice of beam momentum. We assess the expected muon intensity at HIAF and the corresponding statistical sensitivity. For each scheme, we identify its distinctive systematic effects, examine feasible control strategies, and propose quantitative systematic-uncertainty targets. Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0.1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the 0.05 ppm level in Phase-II following the planned HIAF upgrade. At the ultimate projected precision, the measurement would provide a stringent test of the Standard Model and probe new physics at multi-TeV scales. A focus on negative-muon measurements would enable direct comparison with existing high-precision positive-muon results and strengthen tests of CPT symmetry in the muon sector within the Standard-Model Extension, with a projected sensitivity at the $10^{-24}$ GeV level, an order of magnitude beyond current limits.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑