arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2307.05482physics.flu-dyn
收藏

狭窄通道内火焰-壁面相互作用期间 kHz 速率的高精度二维表面磷光测温

High-precision 2D surface phosphor thermometry at kHz-rates during flame-wall interaction in narrow passages

Anthony O. Ojo, David Escofet-Martin, Brian Peterson

AI总结:

提出基于ScVO4:Bi3+的kHz级二维磷光测温方法,并结合CH*成像揭示狭窄缝隙内火焰-壁面相互作用中褶皱火焰导致的局部壁温差异与冷却机制。

摘要:

本工作展示了在狭窄通道内火焰-壁面相互作用(FWI)期间进行的高速二维壁面温度测量。此类测量对于理解微型燃烧器和特定发动机缝隙内发生的瞬态壁面传热与火焰行为至关重要。壁面温度采用掺铋钒酸钪磷光体(ScVO4:Bi3+)进行测量。ScVO4:Bi3+具有较短的磷光寿命(室温下为2微秒),可实现 kHz 级测量速率。ScVO4:Bi3+还表现出较高的温度灵敏度,从而在295–335 K温度范围内实现低于0.5 K的单次测量精度。实验使用发射400 nm光的倍频钛宝石(Ti:Sapphire)激光器激发ScVO4:Bi3+,并在22 × 22 mm²区域内测量壁面温度,空间分辨率为380微米。研究将磷光测温与CH*成像以1 kHz相结合,在专为传热研究设计的定容腔体内,测量2 mm缝隙通道中火焰与壁面温度(Twall)的时空动力学。测量结果描述了与瞬态FWI事件相关的Twall特征,包括与褶皱火焰锋面相关的独特Twall特征。在本文操作条件下,与火焰尖点相关的Twall始终比火焰波峰区域低5–20 K。最大差异出现在大型尖点形成过程中,此时火焰尖点谷底处可观察到明显的局部壁面冷却。这种冷却特征可能由内在的火焰-流动不稳定性引起,该不稳定性会在局部和时间上冷却壁面。

英文摘要:

This work demonstrates high-speed 2D wall temperature measurements occurring during flame-wall interaction (FWI) within a narrow channel. Such measurements are essential to understand transient wall heat transfer and flame behavior occurring within micro-combustors and designated engine crevices. Wall temperature is measured using the phosphor Bismuth-doped Scandium vanadate (ScVO4:Bi3+). ScVO4:Bi3+ exhibits a short phosphorescence lifetime (2 microseconds at room temperature), enabling kHz measurement rates. ScVO4:Bi3+ also exhibits a high temperature sensitivity, which yields single-shot precision less than 0.5 K within the temperature range of 295 - 335 K. A frequency-doubled Ti:Sapphire laser emitting light at 400 nm is used to excite ScVO4:Bi3+, and wall temperature is measured within a 22 x 22 mm2 region with 380 micrometer spatial resolution. Phosphor thermometry and CH* imaging are combined at 1 kHz to measure the spatiotemporal dynamics of the flame and wall temperature (Twall) within a 2 mm crevice passage in a fixed volume chamber designed for heat transfer studies. Measurements describe Twall signatures associated with transient FWI events, including unique Twall features associated with wrinkled flame fronts. For our operating conditions, Twall associated with flame cusps consistently exhibit temperatures 5 - 20 K lower than flame crest regions. The most extreme difference is seen for large cusp formation, where local wall cooling is noticeable at the trough of the flame cusp. This cooling feature may be caused by intrinsic flame-flow instabilities, which locally and temporally cool the wall.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑