In the standard homodyne configuration, an unknown optical state is combined with a local oscillator (LO) on a beam splitter (BS). Good quadrature measurements require a high-amplitude LO and two high-efficiency photodiodes whose signals are subtracted and normalized. By changing the LO phase, it is then possible to infer the optical state in the mode matching the LO. For quantum information processing, the states of interest are in well-separated modes, corresponding to a pulsed configuration with one relevant LO mode per measurement. We theoretically investigate what can be learned about the unknown optical state by counting photons in one or both outgoing paths after the BS, keeping the LO mode fixed but choosing its phase and magnitude. We consider measurement configurations where the BS acts differently on different sets of matching modes. When the BS acts identically on all matching modes it is possible to determine the content of the unknown optical state in the mode matching the LO conditional on each number of photons in the orthogonal modes on the same path. In particular, if both the phase and the intensity of the LO can be varied, then the statistics of just one of the counters is enough to infer these parameters, while in the case of an LO with fixed intensity both detectors are needed to accomplish this. Our results are derived by demonstrating a bijection, or lack thereof, between the probability distributions over the space of outcomes of the counter(s) and certain parameters of the unknown state for different measurement configuration. We report an experiment that was conducted to demonstrate the theory in the case where the BS acts differently depending on the polarization.
Sensitivity Evaluation of SU(1,1) Interferometers with Arbitrary Input Probe State and Homodyne Detections
Indian Institute of Technology Kharagpur(印度理工学院卡拉格普尔分校);Université Paris-Saclay(巴黎萨克雷大学);CNRS(法国国家科学研究中心);CentraleSupélec(中央理工-高等电力学院);Centre for Nanosciences and Nanotechnologies, CNRS, Université Paris-Saclay(法国国家科学研究中心-巴黎萨克雷大学纳米科学与工程中心)
Optimized phase sensing in a truncated SU(1,1) interferometer
零差检测常用于基于非线性光学增益介质的干涉仪。对于种子的配置,“截断SU(1,1)”干涉仪Anderson等人(Phys. Rev. A 95,063843(2017))展示了如何优化零差检测方案,并从理论上证明了它可以使相位估计的量子Cramer-Rao界限饱和。在这项工作中,我们扩展了这些结果,考虑到在截断SU(1,1)干涉仪的损失,并确定最佳的零差检测方案的相位测量。此外,我们建立了一个截断SU(1,1)干涉仪和实验证明,这种优化方案实现了降低噪声水平,相应的增强潜在的相位灵敏度,相比一个典型的零差检测方案的双模压缩态。在这样做的过程中,我们还证明了我们可以用这个设备击败标准量子极限的程度的提高。
Hidden quantum correlations in cavity-based quantum optics
University of Lille(里尔大学);Université Côte d’Azur(蔚蓝海岸大学);CNRS, UMR 8523 – PhLAM – Physique des Lasers Atomes et Molécules(法国国家科学研究中心,UMR 8523 – 激光、原子与分子物理实验室);CNRS, Institut de physique de Nice(法国国家科学研究中心,尼斯物理研究所)
Barcelona Supercomputing Center (BSC)(巴塞罗那超级计算中心);Universitat de Barcelona(巴塞罗那大学);ICFO–Institut de Ciencies Fotoniques, The Barcelona Institute of Science and Technology(ICFO-光子科学研究所,巴塞罗那科学与技术研究院);Universidad de Buenos Aires, Instituto de Física de Buenos Aires (IFIBA)(布宜诺斯艾利斯大学,布宜诺斯艾利斯物理研究所)
Beating the spectroscopic Rayleigh limit via post-processed heterodyne detection
Centre for Quantum Optical Technologies, Centre of New Technologies, University of Warsaw(华沙大学量子光学技术中心、新技术中心);Faculty of Physics, University of Warsaw(华沙大学物理学院)
Temporal limitations and digital data processing in continuous variable measurements of non-Gaussian states
Université Côte d’Azur(蔚蓝海岸大学);Institut de Physique de Nice(尼斯物理研究所);European Laboratory for Non-linear Spectroscopy (LENS)(欧洲非线性光谱学实验室);University of Florence(佛罗伦萨大学);Istituto Nazionale di Ottica (CNR-INO)(意大利国家光学研究所)
Generation and detection of squeezed states via a synchronously pumped optical parametric oscillator
Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano(意大利国家核物理研究所(INFN)米兰分部);Istituto di Fotonica e Nanotecnologie – CNR(光子学与纳米技术研究所 - 意大利国家研究委员会);Politecnico di Milano(米兰理工大学)