arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2305.06963cs.CVcs.LG
收藏

级联交叉注意力网络用于基于Transformer的数据高效全切片图像分类

Cascaded Cross-Attention Networks for Data-Efficient Whole-Slide Image Classification Using Transformers

University Hospital Aachen(亚琛大学医院);RWTH Aachen University(亚琛工业大学)

Firas Khader, Jakob Nikolas Kather, Tianyu Han, Sven Nebelung, Christiane Kuhl, Johannes Stegmaier, Daniel Truhn

AI总结:

提出级联交叉注意力网络(CCAN),线性复杂度处理全切片图像,在肺癌和肾癌数据集上达到高AUC,并适用于低数据场景。

摘要:

全切片成像技术能够对组织学标本进行高分辨率图像的采集和数字化。因此,使用深度学习模型对这些图像进行自动化分析具有很高的需求。Transformer架构已被提出作为有效利用高分辨率信息的可能候选方案。在此方案中,全切片图像被分割成较小的图像块,并从这些图像块中提取特征标记。然而,虽然传统Transformer允许同时处理大量输入标记,但其计算需求随输入标记数量呈二次方增长,因此也随图像块数量呈二次方增长。为解决这一问题,我们提出了一种新颖的级联交叉注意力网络(CCAN),该网络基于交叉注意力机制,其计算复杂度随提取的图像块数量呈线性增长。我们的实验表明,该架构在两个公共数据集上至少与基于注意力的最先进方法持平,甚至优于它们:在肺癌用例(TCGA NSCLC)中,我们的模型达到了平均受试者工作特征曲线下面积(AUC)为0.970±0.008;在肾癌(TCGA RCC)中,达到了平均AUC为0.985±0.004。此外,我们展示了所提出的模型在低数据场景下具有高效性,使其成为在资源受限环境中分析全切片图像的有前景的方法。为促进该方向的研究,我们在GitHub上公开了代码:XXX。

英文摘要:

Whole-Slide Imaging allows for the capturing and digitization of high-resolution images of histological specimen. An automated analysis of such images using deep learning models is therefore of high demand. The transformer architecture has been proposed as a possible candidate for effectively leveraging the high-resolution information. Here, the whole-slide image is partitioned into smaller image patches and feature tokens are extracted from these image patches. However, while the conventional transformer allows for a simultaneous processing of a large set of input tokens, the computational demand scales quadratically with the number of input tokens and thus quadratically with the number of image patches. To address this problem we propose a novel cascaded cross-attention network (CCAN) based on the cross-attention mechanism that scales linearly with the number of extracted patches. Our experiments demonstrate that this architecture is at least on-par with and even outperforms other attention-based state-of-the-art methods on two public datasets: On the use-case of lung cancer (TCGA NSCLC) our model reaches a mean area under the receiver operating characteristic (AUC) of 0.970 $\pm$ 0.008 and on renal cancer (TCGA RCC) reaches a mean AUC of 0.985 $\pm$ 0.004. Furthermore, we show that our proposed model is efficient in low-data regimes, making it a promising approach for analyzing whole-slide images in resource-limited settings. To foster research in this direction, we make our code publicly available on GitHub: XXX.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑