arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2305.01900astro-ph.IMastro-ph.HE
收藏

在 SiSeRO 器件上演示重复非破坏性读出(RNDR)

Demonstrating repetitive non-destructive readout (RNDR) with SiSeRO devices

Tanmoy Chattopadhyay, Sven Herrmann, Peter Orel, Kevan Donlon, Gregory Prigozhin, R. Glenn Morris, Michael Cooper, Beverly LaMarr, Andrew Malonis, Steven W. All… 展开作者

Tanmoy Chattopadhyay, Sven Herrmann, Peter Orel, Kevan Donlon, Gregory Prigozhin, R. Glenn Morris, Michael Cooper, Beverly LaMarr, Andrew Malonis, Steven W. Allen, Marshall W. Bautz, Chris Leitz

AI总结:

本文首次在 SiSeRO 器件上实现重复非破坏性读出(RNDR),通过九次循环平均将读出噪声降至约 2 个电子,接近硅的法诺极限,为下一代天文 X 射线望远镜提供亚电子噪声光谱成像技术。

摘要:

我们首次在单电子灵敏读出(SiSeRO)器件上演示了所谓的重复非破坏性读出(RNDR)。SiSeRO 是麻省理工学院林肯实验室为电荷耦合器件(CCD)图像传感器开发的一种新型片上电荷探测器输出级。该技术使用一个 p-MOSFET 晶体管,其晶体管沟道下方有一个耗尽型内部栅极。晶体管的源漏电流通过电荷转移到内部栅极来调制。RNDR 是通过在内部栅极与求和阱(SW,即最后一个串行寄存器)之间非破坏性地转移信号电荷来实现的。非破坏性电荷转移的优势在于,每个像素的信号电荷可以在每个转移周期结束时进行测量,并且通过对大量测量次数($\mathrm{N_{cycle}}$)取平均,总噪声可以降低 1/$\mathrm{\sqrt{N_{cycle}}}$ 倍。在我们使用原型 SiSeRO 器件进行的实验中,我们实现了九次($\mathrm{N_{cycle}}$ = 9)RNDR 循环,获得了约 2 个电子的读出噪声(等效噪声电荷或 ENC),在 5.9 keV 处光谱分辨率接近硅的法诺极限。这些初步结果非常令人鼓舞,证明了 RNDR 技术在 SiSeRO 中的成功实现。它们也为未来使用更优化的测试台(更好的温度控制、更多次数的 RNDR 循环、RNDR 优化的 SiSeRO 器件)进行实验奠定了基础,这些测试台应能实现亚电子噪声灵敏度。这种新型器件类别为需要极低噪声光谱成像器的下一代天文 X 射线望远镜提供了一项令人兴奋的技术。亚电子灵敏度还增加了进行原位绝对校准的能力,从而能够对低能仪器响应进行前所未有的表征。

英文摘要:

We demonstrate so-called repetitive non-destructive readout (RNDR) for the first time on a Single electron Sensitive Readout (SiSeRO) device. SiSeRO is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors, developed at MIT Lincoln Laboratory. This technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. RNDR was realized by transferring the signal charge non-destructively between the internal gate and the summing well (SW), which is the last serial register. The advantage of the non-destructive charge transfer is that the signal charge for each pixel can be measured at the end of each transfer cycle and by averaging for a large number of measurements ($\mathrm{N_{cycle}}$), the total noise can be reduced by a factor of 1/$\mathrm{\sqrt{N_{cycle}}}$. In our experiments with a prototype SiSeRO device, we implemented nine ($\mathrm{N_{cycle}}$ = 9) RNDR cycles, achieving around 2 electron readout noise (equivalent noise charge or ENC) with spectral resolution close to the fano limit for silicon at 5.9 keV. These first results are extremely encouraging, demonstrating successful implementation of the RNDR technique in SiSeROs. They also lay foundation for future experiments with more optimized test stands (better temperature control, larger number of RNDR cycles, RNDR-optimized SiSeRO devices) which should be capable of achieving sub-electron noise sensitivities. This new device class presents an exciting technology for next generation astronomical X-ray telescopes requiring very low-noise spectroscopic imagers. The sub-electron sensitivity also adds the capability to conduct in-situ absolute calibration, enabling unprecedented characterization of the low energy instrument response.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑