arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2304.07962astro-ph.HEastro-ph.CO
收藏

利用NuSTAR的杂散光测量3-20keV能段的宇宙X射线背景

Measuring the Cosmic X-ray Background in 3-20keV with Straylight from NuSTAR

Steven Rossland, Daniel Wik, Brian Grefenstette, Nico Cappelluti, Francesca Civano, Fabio Gastaldello, Roberto Gilli, Fiona Harrison, Ann Hornschemeier, Ryan Hi… 展开作者

Steven Rossland, Daniel Wik, Brian Grefenstette, Nico Cappelluti, Francesca Civano, Fabio Gastaldello, Roberto Gilli, Fiona Harrison, Ann Hornschemeier, Ryan Hickox, Roman Krivonos, Kristin Madsen, Silvano Molendi, Andrew Ptak, Daniel Stern, Andreas Zoglauer

AI总结:

本研究利用NuSTAR天文台2012-2017年的杂散光数据,通过空间拟合测量了3-20keV能段的宇宙X射线背景,其光谱与HEAO 1一致且比多数后续测量低10%。

摘要:

通过分析2012至2017年间NuSTAR X射线天文台大型数据集中杂散光的贡献,我们报告了在3-20 keV能段对宇宙X射线背景的测量结果。这些数据覆盖了约20%的天区,同时避开了银河系脊X射线发射,且与先前使用NuSTAR的测量相比,对深度巡天区域的权重依赖更小。窄能带图像在探测器空间中叠加,并使用分别代表杂散光以及宇宙X射线背景和仪器背景预期的均匀分布模型进行空间拟合。我们从地球遮挡数据中建立了基准通量值,并在Crab的杂散光观测中验证了拟合方法,这些观测进一步校准了最终光谱。我们展示了FPMA和FPMB探测器阵列独立测得的宇宙X射线背景光谱,它们与HEAO 1的经典表征高度一致,且比大多数后续测量值低10%;FPMA的3-20 keV通量为2.63×10^-11 erg s^-1 cm^-2 deg^-2,FPMB的通量为2.58×10^-11 erg s^-1 cm^-2 deg^-2。我们结合先前的宇宙X射线背景测量结果讨论了这些发现,并考虑了系统不确定性对我们光谱的影响。

英文摘要:

By characterizing the contribution of stray light to large datasets from the NuSTAR X-ray observatory collected over 2012--2017, we report a measurement of the cosmic X-ray background in the 3--20 keV energy range. These data represent $\sim20\%$ sky coverage while avoiding Galactic Ridge X-ray emission and are less weighted by deep, survey fields than previous measurements with NuSTAR. Images in narrow energy bands are stacked in detector space and spatially fit with a model representing the stray light and uniform pattern expected from the cosmic X-ray background and the instrumental background, respectively. We establish baseline flux values from Earth-occulted data and validate the fitting method on stray light observations of the Crab, which further serve to calibrate the resulting spectra. We present independent spectra of the cosmic X-ray background with the FPMA and FPMB detector arrays, which are in excellent agreement with the canonical characterization by HEAO 1 and are $10\%$ lower than most subsequent measurements; $F_{\rm{3-20~keV}}^{FPMA} = 2.63 \times 10^{-11}~\rm{erg~s^{-1}~cm^{-2}~deg^{-2}}$ and $F_{\rm{3-20~keV}}^{FPMB} = 2.58 \times 10^{-11}~\rm{erg~s^{-1}~cm^{-2}~deg^{-2}}$. We discuss these results in light of previous measurements of the cosmic X-ray background and consider the impact of systematic uncertainties on our spectra.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑