Observation of a low energy nuclear recoil peak in the neutron calibration data of the CRESST-III Experiment
CRESST Collaboration, G. Angloher, S. Banik, G. Benato, A. Bento, A. Bertolini, R. Breier, C. Bucci, J. Burkhart, L. Canonica, A. D'Addabbo, S. Di Lorenzo, L. E… 展开作者
CRESST Collaboration, G. Angloher, S. Banik, G. Benato, A. Bento, A. Bertolini, R. Breier, C. Bucci, J. Burkhart, L. Canonica, A. D'Addabbo, S. Di Lorenzo, L. Einfalt, A. Erb, F. v. Feilitzsch, S. Fichtinger, D. Fuchs, A. Fuss, A. Garai, V. M. Ghete, S. Gerster, P. Gorla, P. V. Guillaumon, S. Gupta, D. Hauff, M. Ješkovský, J. Jochum, M. Kaznacheeva, A. Kinast, H. Kluck, H. Kraus, A. Langenkämper, M. Mancuso, L. Marini, L. Meyer, V. Mokina, A. Nilima, M. Olmi, T. Ortmann, C. Pagliarone, L. Pattavina, F. Petricca, W. Potzel, P. Povinec, F. Pröbst, F. Pucci, F. Reindl, J. Rothe, K. Schäffner, J. Schieck, D. Schmiedmayer, S. Schönert, C. Schwertner, M. Stahlberg, L. Stodolsky, C. Strandhagen, R. Strauss, I. Usherov, F. Wagner, M. Willers, V. Zema
新一代低质量暗物质直接探测的特点是其探测阈值远低于 100 eV,比常用 X 射线刻度源的能量低得多。这就需要具有亚 keV 能量的新型刻度源。在寻找核反冲信号时,理想情况下刻度源应在相关能量范围内产生单能核反冲。最近,有人提出了一种新的刻度方法:基于中子在 $^{182}$W 上的辐射俘获,随后通过单次 $γ$ 发射退激,从而在 112 eV 处产生核反冲峰。过去几年中,CRESST-III 暗物质探测运行了多个基于 CaWO$_{4}$、探测阈值低于 100 eV 的探测器模块。我们报告,在三个不同探测器模块受不同 AmBe 刻度源中子照射期间记录的数据中,观测到了位于预期能量 112 eV 附近的峰。我们将观测峰的性质与 Geant-4 模拟进行比较,并评估将其用于 CRESST-III 探测器能量刻度的前景。
英文摘要:
New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Recently, a new calibration method based on the radiative neutron capture on $^{182}$W with subsequent de-excitation via single $γ$-emission leading to a nuclear recoil peak at 112 eV was proposed. The CRESST-III dark matter search operated several CaWO$_{4}$-based detector modules with detection thresholds below 100 eV in the past years. We report the observation of a peak around the expected energy of 112 eV in the data of three different detector modules recorded while irradiated with neutrons from different AmBe calibration sources. We compare the properties of the observed peaks with Geant-4 simulations and assess the prospects of using this for the energy calibration of CRESST-III detectors.
Calibration Plan for the SBC 10-kg Liquid Argon Detector with 100 eV Target Threshold
University of Alberta(阿尔伯塔大学);University of California Riverside(加州大学河滨分校);University of California Santa Barbara(加州大学圣塔芭芭拉分校);Drexel University(德雷塞尔大学);Fermi National Accelerator Laboratory(费米国家加速器实验室);Indiana University South Bend(南本德印第安纳大学);Northeastern Illinois University(伊利诺伊东北大学);Northwestern University(西北大学);Queen's University(女王大学);SNOLAB(斯诺实验室)
Quenching factors for Na recoils as a function of Tl dopant concentrations in NaI(Tl) crystals
Consiglio Nazionale delle Ricerche, Istituto di Nanotecnologia(意大利国家研究委员会纳米技术研究所);Department of Mathematics and Physics, North Carolina Central University(北卡罗来纳中央大学数学与物理系);Department of Nuclear Engineering, North Carolina State University(北卡罗来纳州立大学核工程系);Department of Physics, Duke University(杜克大学物理系);Department of Physics, ETH Zurich(苏黎世联邦理工学院物理系);ETH Zurich - PSI Quantum Computing Hub, Paul Scherrer Institute(保罗谢勒研究所苏黎世联邦理工学院量子计算中心);Gran Sasso Science Institute(格兰萨索科学研究所);INFN - Laboratori Nazionali del Gran Sasso(意大利国家核物理研究所格兰萨索国家实验室);INFN - Sezione di Roma(意大利国家核物理研究所罗马分部);SNOLAB(斯诺实验室);State Key Laboratory of Functional Crystals and Devices, Shanghai Institute of Ceramics, Chinese Academy of Sciences(中国科学院上海硅酸盐研究所功能晶体及器件国家重点实验室);Triangle Universities Nuclear Laboratory(三角大学核实验室)
Improved Modeling of $β$ Electronic Recoils in Liquid Xenon Using LUX Calibration Data
我们在这里报告的方法和技术,用于创建和改进的模型,再现的闪烁和电离响应的双相液体和气体氙时间投影室。从最近发布的稀有元素模拟技术(NEST v2.0)开始,除了外部数据集允许在LUX数据采集条件之外进行外推外,还使用了大型地下氙(LUX)探测器中${}^3$ H和${}^{14}$ C的$β$衰变的电子反冲数据来调整模型。本文还介绍了用于建模复杂的时间和空间检测器的病理,可能会对数据产生不利影响,使用一个简化的模型框架的技术。本报告中概述的方法显示了NEST v2.0可能的强大应用程序的示例,同时还提供了最终的电子反冲模型和探测器参数,这些参数将用于新的分析包,LUX Legacy Analysis Monte Carlo Application(LLAMA),以准确再现LUX数据。由于精确的背景再现对于稀有事件搜索的成功至关重要,例如暗物质直接探测实验,因此这里概述的技术可以用于其他单相和双相氙探测器,以协助精确的ER背景再现。
Low-Energy Nuclear Recoil Calibration of XENONnT with a $^{88}$YBe Photoneutron Source
Columbia University(哥伦比亚大学);Nikhef and the University of Groningen, Van Swinderen Institute(荷兰核物理研究所与格罗宁根大学范斯温德伦研究所);Kamioka Observatory, Institute for Cosmic Ray Research, and Kavli Institute for the Physics and Mathematics of the Universe (WPI), University of Tokyo(东京大学宇宙射线研究所神冈观测站及武利宇宙物理学数学研究所);LPNHE, Sorbonne Université, CNRS/IN2P3(索邦大学国家科学研究中心/法国原子能和替代能源委员会高能物理实验室);Institut für Kernphysik, University of Münster(明斯特大学核物理研究所);INAF-Astrophysical Observatory of Torino, Department of Physics, University of Torino and INFN-Torino(都灵大学物理系、意大利国家天体物理研究所都灵天文台及意大利国家核物理研究所都灵分部);INFN-Laboratori Nazionali del Gran Sasso and Gran Sasso Science Institute(意大利国家核物理研究所格兰萨索国家实验室及格兰萨索科学研究所);Department of Physics, Enrico Fermi Institute & Kavli Institute for Cosmological Physics, University of Chicago(芝加哥大学恩里科·费米研究所、卡弗里宇宙物理学研究所及物理系);New York University Abu Dhabi - Center for Astro, Particle and Planetary Physics(纽约大学阿布扎比分校天体、粒子与行星物理中心);Physik-Institut, University of Zürich(苏黎世大学物理研究所);SUBATECH, IMT Atlantique, CNRS/IN2P3, Nantes Université(南特大学IMT大西洋学院国家科学研究中心/法国原子能和替代能源委员会亚原子与技术研究实验室);Department of Physics and Astronomy, University of Bologna and INFN-Bologna(博洛尼亚大学物理与天文学系及意大利国家核物理研究所博洛尼亚分部)