arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2303.00339astro-ph.IM
收藏

Insight-HXMT星载ME前5年在轨性能

In-orbit Performance of ME onboard Insight-HXMT in the first 5 years

Ying Tan, Xuelei Cao, Weichun Jiang, Xiaobo Li, Bin Meng, Wanchang Zhang, Sheng Yang, Tao Luo, Yudong Gu, Liang Sun, Xiaojing Liu, Yuanyuan Du, Jiawei Yang, Yan… 展开作者

Ying Tan, Xuelei Cao, Weichun Jiang, Xiaobo Li, Bin Meng, Wanchang Zhang, Sheng Yang, Tao Luo, Yudong Gu, Liang Sun, Xiaojing Liu, Yuanyuan Du, Jiawei Yang, Yanjun Xu, Jinyuan Liao, Yupeng Xu, Fangjun Lu, Liming Song, Shuangnan Zhang

摘要:

简介:中能X射线望远镜(ME)是Insight硬X射线调制望远镜(Insight-HXMT)卫星上的准直X射线望远镜。它有1728个Si-PIN像素读出使用54个低噪声专用集成电路(ASIC)。ME覆盖5-30 keV的能量范围,总探测面积为952 cm 2。在任务开始时,ME的典型能量分辨率为3 keV,半高宽(FWHM)为17.8 keV,时间分辨率为255 us。在这项研究中,我们提出了在轨道上的性能ME在其第一个5年的操作。方法:使用机载放射源和天文X射线物体监测ME的性能。ME携带6个用于机载校准的241 Am放射源,可以连续照射校准像素。ME的长期性能演变可以使用校准像素的累积光谱的性质来量化。此外,对蟹状星云和脉冲星的观测被用来检查作为能量函数的探测效率的长期演变。结论:经过5年的运行,仍有742 cm 2的Si-PIN像素正常工作。241 Am发射线的峰位逐渐向高能区移动,意味着ME增益缓慢增加1.43%。对蟹状星云和脉冲星的ME谱的比较表明,E-C关系和再分布矩阵文件对于大多数数据分析工作仍然是可以接受的,并且在探测效率上没有可察觉的变化。

英文摘要:

Introduction: The Medium Energy X-ray telescope (ME) is a collimated X-ray telescope onboard the Insight hard X-ray modulation telescope (Insight-HXMT) satellite. It has 1728 Si-PIN pixels readout using 54 low noise application-specific integrated circuits (ASICs). ME covers the energy range of 5-30 keV and has a total detection area of 952 cm2. The typical energy resolution of ME at the beginning of the mission is 3 keV at 17.8 keV (Full Width at Half Maximum, FWHM) and the time resolution is 255 us. In this study, we present the in-orbit performance of ME in its first 5 years of operation. Methods: The performance of ME was monitored using onboard radioactive sources and astronomical X-ray objects. ME carries six 241Am radioactive sources for onboard calibration, which can continuously illuminate the calibration pixels. The long-term performance evolution of ME can be quantified using the properties of the accumulated spectra of the calibration pixels. In addition, observations of the Crab Nebula and the pulsar were used to check the long-term evolution of the detection efficiency as a function of energy. Conclusion: After 5 years of operation, 742 cm2 of the Si-PIN pixels were still working normally. The peak positions of 241Am emission lines gradually shifted to the high energy region, implying a slow increase in ME gain of 1.43%. A comparison of the ME spectra of the Crab Nebula and the pulsar shows that the E-C relations and the redistribution matrix file are still acceptable for most data analysis works, and there is no detectable variation in the detection efficiency.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑