流动流体的拉伸流变测量。第二部分:使用数值优化的驻点微流控装置比较稀聚合物溶液的单轴、平面和双轴拉伸流变
Extensional rheometry of mobile fluids. Part II: Comparison between the uniaxial, planar and biaxial extensional rheology of dilute polymer solutions using numerically-optimized stagnation point microfluidic devices
AI总结:
本文利用OUBER和OSCER微流控装置比较稀聚合物溶液在单轴、平面和双轴拉伸下的流变行为,提出基于宏观功率平衡的新分析方法,揭示超稀溶液符合FENE哑铃模型及单轴流中弹性不稳定性发生更早的现象。
摘要:
在本文第一部分[Haward等人,已提交(2023)]中,我们提出了一种新的三维微流控装置(优化的单轴和双轴拉伸流变仪,OUBER),用于产生近似均匀的单轴和双轴拉伸流动。在本文第二部分中,我们使用OUBER装置研究了一些模型稀聚合物溶液的单轴和双轴拉伸流变。我们还将结果与在优化形状十字槽拉伸流变仪[或OSCER,Haward等人,Phys. Rev. Lett.(2012)]中平面拉伸条件下进行的测量进行了比较。在每种情况下(单轴、平面和双轴拉伸),我们使用微粒子图像测速法测量拉伸速率随施加流速的变化,并测量每个装置上的过量压降,以估计流体中产生的拉伸应力差。我们提出了一种新的分析方法,基于求解流经每个装置的宏观功率平衡,以改进从测得压降获得的拉伸应力差估计。基于这一分析,我们发现对于我们最稀的聚合物样品,即“超稀”样品,其拉伸粘度可以很好地用有限可扩展非线性弹性哑铃模型描述。在此极限下,高Weissenberg数(Wi)时的双轴拉伸粘度是单轴和平面拉伸粘度的一半。在较高聚合物浓度下,实验测量结果偏离模型预测,这归因于聚合物在拉伸流中解卷时分子间相互作用的开始。具有实际意义(和基础研究意义)的是,弹性不稳定性在单轴拉伸流中发生的Wi显著低于双轴或平面拉伸流,限制了这种流动类型在拉伸粘度测量中的实用性。
英文摘要:
In Part I of this paper [Haward et al. submitted (2023)], we presented a new three-dimensional microfluidic device (the optimized uniaxial and biaxial extensional rheometer, OUBER) for generating near-homogeneous uniaxial and biaxial elongational flows. In this Part II of the paper, we employ the OUBER device to examine the uniaxial and biaxial extensional rheology of some model dilute polymer solutions. We also compare the results with measurements made under planar extension in the optimized-shape cross-slot extensional rheometer [or OSCER, Haward et al. Phys. Rev. Lett. (2012)]. In each case (uniaxial, planar and biaxial extension), we use micro-particle image velocimetry to measure the extension rate as a function of the imposed flow rate, and we measure the excess pressure drop across each device in order to estimate the tensile stress difference generated in the fluid. We present a new analysis, based on solving the macroscopic power balance for flow through each device, to refine the estimate of the tensile stress difference obtained from the measured pressure drop. Based on this analysis, we find that for our most dilute polymer sample, which is "ultradilute", the extensional viscosity is well described by the finitely extensible non-linear elastic dumbbell model. In this limit, the biaxial extensional viscosity at high Weissenberg numbers (Wi) is half that of the uniaxial and planar extensional viscosities. At higher polymer concentrations, the experimental measurements deviate from the model predictions, which is attributed to the onset of intermolecular interactions as polymers unravel in the extensional flows. Of practical significance (and fundamental interest), elastic instability occurs at a significantly lower Wi in uniaxial extensional flow than in either biaxial or planar extensional flow, limiting the utility of this flow type for extensional viscosity measurement.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。