Extensional rheometry of mobile fluids. Part I: OUBER, an optimized uniaxial and biaxial extensional rheometer

Simon J. Haward, Francisco Pimenta, Stylianos Varchanis, Daniel W. Carlson, Kazumi Toda-Peters, Manuel A. Alves, Amy Q. Shen

AI总结:

本文通过数值优化设计并微尺度制造了名为 OUBER 的六臂十字槽装置,用于在低雷诺数下精确施加单轴和双轴驻点拉伸流动,并通过微断层扫描粒子图像测速验证了其流场准确性,为后续稀聚合物溶液拉伸流变测量提供了新工具。

摘要:

我们对一种“六臂十字槽”装置进行了数值优化,得到了若干种三维流体通道形状,这些形状被设计用于在具有四个入口和两个出口(或两个入口和四个出口)以及牛顿蠕流条件的约束下,施加接近理想的单轴(或双轴)驻点拉伸流动。在各种数值生成的几何构型中,选择了一种最适合在微尺度下制造的构型,并且采用 Oldroyd-B 模型和 Phan-Thien and Tanner 模型的数值模拟证实,对于恒定粘度和剪切变稀的粘弹性流体,在所选择的几何构型中都能观察到最优流场。该几何构型被我们命名为优化的单轴与双轴拉伸流变仪(OUBER),通过选择性激光诱导刻蚀熔融石英基底,在微尺度下以高精度完成了制造。使用一种粘性牛顿流体,其折射率与光学透明的微流体装置相匹配,我们进行了微断层扫描粒子图像测速,以在低雷诺数(< 0.1)下解析驻点周围相当大体积内的流场。流动测速结果证实了所期望和预测的流动被准确施加,在驻点周围较宽区域内施加了变形速率基本均匀的纯拉伸流动。在本文的第二部分中 [Haward 等人,J. Rheol. 已投稿(2023)],将利用 OUBER 几何构型中的压降测量来评估稀聚合物溶液的单轴和双轴拉伸流变测量,并与使用优化形状十字槽拉伸流变仪(OSCER,Haward 等人,Phys. Rev. Lett.,2012)在平面拉伸中进行的测量进行比较。

英文摘要:

We present a numerical optimization of a "6-arm cross-slot" device, yielding several three-dimensional shapes of fluidic channels designed to impose close approximations to ideal uniaxial (or biaxial) stagnation point extensional flow under the constraints of having four inlets and two outlets (or two inlets and four outlets) and Newtonian creeping flow conditions. Of the various numerically-generated geometries, one is selected as being most suitable for fabrication at the microscale, and numerical simulations with the Oldroyd-B and Phan-Thien and Tanner models confirm that the optimal flow fields in the chosen geometry are observed for both constant viscosity and shear thinning viscoelastic fluids. Fabrication of the geometry, which we name the optimized uniaxial and biaxial extensional rheometer (OUBER), is achieved with high precision at the microscale by selective laser-induced etching of a fused-silica substrate. Employing a viscous Newtonian fluid with a refractive index matched to that of the optically transparent microfluidic device, we conduct microtomographic-particle image velocimetry in order to resolve the flow field at low Reynolds number (< 0.1) in a substantial volume around the stagnation point. The flow velocimetry confirms the accurate imposition of the desired and predicted flows, with pure extensional flow at an essentially uniform deformation rate being applied over a wide region around the stagnation point. In Part II of this paper [Haward et al., J. Rheol. submitted (2023)], pressure drop measurements in the OUBER geometry will be used to assess the uniaxial and biaxial extensional rheometry of dilute polymeric solutions, in comparison to measurements made in planar extension using an optimized-shape cross-slot extensional rheometer (OSCER, Haward et al, Phys. Rev. Lett., 2012).

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑