arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2211.07532physics.med-ph
收藏

使用压缩感知扩展编码的7 T高分辨率单次激发螺旋扩散加权成像

High-resolution single-shot spiral diffusion-weighted imaging at 7T using expanded encoding with compressed sensing

Gabriel Varela-Mattatall, Paul I. Dubovan, Tales Santini, Kyle M. Gilbert, Ravi S. Menon, Corey A. Baron

摘要:

目的:扩展的编码模型结合了空间和时间变化的场扰动,用于重建过程中的校正。到目前为止,这些重建使用共轭梯度法与早期停止作为隐式正则化。然而,这种方法对于低SNR情况(如扩散或高分辨率MRI)可能是次优的。在这里,我们调查的程度,l1小波正则化,或等效的压缩感知(CS),结合扩展编码,提高了空间分辨率,读出时间和SNR之间的权衡单次拍摄螺旋扩散加权成像在7 T。使用我们的开源GPU支持的重建工具箱MatMRI进行重建,该工具箱允许包含扩展编码模型的不同组件,无论是否有CS。研究方法:在体内加速单次发射螺旋获得五个加速因子(2-6)和三个面内空间分辨率(1.5,1.3和1.1 mm)。从体内重建,我们估计扩散张量和计算分数各向异性地图。然后,使用模拟来定量研究和验证基于CS的正则化与已知的地面实况相比对图像质量的影响。结果:使用CS时,体内重建显示图像质量改善,保留了小特征。仿真结果表明,联合使用的扩展编码模型和CS提高了图像重建的准确性(降低均方误差)的范围内的加速因素的调查。结论:扩展的编码模型和CS正则化是单次激发螺旋扩散MRI的互补工具,它可以实现更高的空间分辨率和更高的加速因子。

英文摘要:

Purpose: The expanded encoding model incorporates spatially- and time-varying field perturbations for correction during reconstruction. So far, these reconstructions have used the conjugate gradient method with early stopping used as implicit regularization. However, this approach is likely suboptimal for low-SNR cases like diffusion or high-resolution MRI. Here, we investigate the extent that l1-wavelet regularization, or equivalently compressed sensing (CS), combined with expanded encoding improves trade-offs between spatial resolution, readout time and SNR for single-shot spiral diffusion-weighted imaging at 7T. The reconstructions were performed using our open-source GPU-enabled reconstruction toolbox, MatMRI, that allows inclusion of the different components of the expanded encoding model, with or without CS. Methods: In vivo accelerated single-shot spirals were acquired with five acceleration factors (2-6) and three in-plane spatial resolutions (1.5, 1.3, and 1.1 mm). From the in vivo reconstructions, we estimated diffusion tensors and computed fractional anisotropy maps. Then, simulations were used to quantitatively investigate and validate the impact of CS-based regularization on image quality when compared to a known ground truth. Results: In vivo reconstructions revealed improved image quality with retainment of small features when CS was used. Simulations showed that the joint use of the expanded encoding model and CS improves accuracy of image reconstructions (reduced mean-squared error) over the range of acceleration factors investigated. Conclusion: The expanded encoding model and CS regularization are complementary tools for single-shot spiral diffusion MRI, which enables both higher spatial resolutions and higher acceleration factors.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑