arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2210.07091astro-ph.SRastro-ph.GAastro-ph.IM
收藏

M 31最亮行星状星云的N/O丰度比和原始质量

On the N/O abundance ratio and the progenitor mass for the most luminous planetary nebulae of M 31

Toshiya Ueta, Masaaki Otsuka

摘要:

等离子体诊断是研究线发射气体系统物理和化学性质的基础。为了正确地执行等离子体诊断,必须正确地校正输入光谱的消光。这仅仅是因为确定消光程度取决于线发射气体的物理性质。因此,消光校正和等离子体诊断必须同时进行,并自洽。通过比较的分析结果进行了9个明亮的行星状星云在M 31的样本,并没有适当的消光校正和等离子体诊断,我们演示了如何初始假设的物理条件的线发射气体消光校正将损害整个分析的结果。虽然电子密度/温度相对不受强加的不一致假设的影响,但受损的消光将导致经消光校正的谱线强度的系统性偏移,这因此将对所得离子和元素丰度以及从不正确的结果做出的其他推断产生不利影响。我们发现,这M 31 PN样本只是代表周围的低质量行星状星云祖星的质量范围的高质量端从现有的理论模型的预期。看来,在以前的研究中提出的怀疑-这些PNE是有害的氮过剩-仅仅是由于明显低估灭绝,起源于灭绝校正强加的不一致的假设。在更大的范围内,在文献中的等离子体诊断的结果,而不寻求同时与消光校正的自洽性,必须谨慎处理。理想情况下,这些先前的结果应该通过寻求同时自我一致性来重新评估。

英文摘要:

Plasma diagnostics are the bases of investigation into the physical and chemical properties of line-emitting gaseous systems. To perform plasma diagnostics properly, it is essential to correct the input spectrum for extinction properly. This is simply because determining the degree of extinction is dependent on the physical properties of the line-emitting gas. Hence, both extinction correction and plasma diagnostics have to be performed simultaneously and self-consistently. By comparing the results of analyses performed for a sample of nine bright planetary nebulae in M 31 with and without the proper extinction correction and plasma diagnostics, we demonstrate how initial assumptions for the physical conditions of the line-emitting gas in extinction correction would compromise the results of the entire analyses. While the electron density/temperature are relatively immune to the imposed inconsistent assumptions, the compromised extinction would cause systematic offsets in the extinction-corrected line strengths, which consequently would impose adverse effects on the resulting ionic and elemental abundances, and other inferences made from the incorrect results. We find that this M 31 PN sample simply represents those around the high-mass end of the mass range for low-mass planetary nebula progenitor stars as expected from the existing theoretical models. It appears that the suspicion raised in the previous study - these PNe being anomalously nitrogen overabundant - is simply caused by the apparent underestimate in extinction that originates from the imposed inconsistent assumptions in extinction correction. In a larger context, the results of plasma diagnostics in the literature without seeking simultaneous self-consistency with extinction correction have to be handled cautiously. Ideally, such previous results should be re-evaluated by seeking simultaneous self-consistency.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑