ELT-HARMONI is the first light visible and near-IR integral field spectrograph (IFS) for the ELT. It covers a large spectral range from 450nm to 2450nm with resolving powers from 3500 to 18000 and spatial sampling from 60mas to 4mas. It can operate in two Adaptive Optics modes - SCAO (including a High Contrast capability) and LTAO - or with NOAO. The project is preparing for Final Design Reviews.
The High Contrast Module (HCM) will allow HARMONI to perform direct imaging and spectral analysis of exoplanets up to one million times fainter than their host star. Quasi-static aberrations are a limiting factor and must be calibrated as close as possible to the focal plane masks to reach the specified contrast. A Zernike sensor for Extremely Low-level Differential Aberrations (ZELDA) will be used in real-time and closed-loop operation at 0.1Hz frequency for this purpose. Unlike a Shack-Hartmann, the ZELDA wavefront sensor is sensitive to Island and low-wind effects. The ZELDA sensor has already been tested on VLT-SPHERE and will be used in other instruments. Our objective is to adapt this sensor to the specific case of HARMONI.
A ZELDA prototype is being both simulated and experimentally tested at IPAG. Its nanometric precision has first been checked in 2020 in the case of slowly evolving, small wavefront errors, and without dispersion nor turbulence residuals. On this experimental basis, we address the performance of the sensor under realistic operational conditions including residuals, mis-centring, dispersion, sensitivity, etc. Atmospheric refraction residuals were introduced by the use of a prism, and turbulence was introduced by a spatial light modulator which is also used to minimise wavefront residuals in a closed loop in the observing conditions expected with HARMONI.
HARMONI at ELT: line spread functions in a diffraction limited spectrometer
UKATC, Royal Observatory Edinburgh(英国天文技术控制中心,爱丁堡皇家天文台);Oxford University(牛津大学);Aix-Marseille Université, CNRS, CNES, LAM(艾克斯-马赛大学,法国国家科学研究中心,法国国家空间研究中心,拉格朗日实验室);Université Lyon 1, CNRS, Centre de Recherche Astrophysique de Lyon (CRAL)(里昂第一大学,法国国家科学研究中心,里昂天体物理研究中心);Instituto de Astrofísica de Canarias (IAC)(加那利天体物理学研究所);Department of Physics, Durham University(杜伦大学物理系)
Reaching the fundamental sensitivity limit of wavefront sensing on arbitrary apertures with the Phase Induced Amplitude Apodized Zernike Wavefront Sensor (PIAA-ZWFS)
HARMONI at ELT: Reoptimization of the NGSS natural guide star sensors system for MCAO compatibility
Aix Marseille Univ, CNRS, CNES, LAM(艾克斯-马赛大学,法国国家科学研究中心,法国国家太空研究中心,天体物理学与行星学实验室);Durham University, Centre for Advanced Instrumentation(杜伦大学,先进仪器中心);Centro de Astrobiología (CAB), CSIC-INTA(天体生物学中心,西班牙高等科学研究理事会-国家航空航天技术研究所);Université Grenoble Alpes, CNRS, IPAG(格勒诺布尔阿尔卑斯大学,法国国家科学研究中心,天体物理与行星学研究所);DOTA, ONERA(航天技术部门,法国航空与航天研究局);Instituto de Astrofísica de Canarias (IAC), Universidad de La Laguna(加那利群岛天体物理研究所,拉帕鲁纳大学)
Calibration of quasi-static aberrations in exoplanet direct-imaging instruments with a Zernike phase-mask sensor. II. Concept validation with ZELDA on VLT/SPHERE
HARMONI@ELT: instrument design, performance, and science capabilities
LAM, Aix Marseille Univ., CNRS, CNES(LAM,艾克斯-马赛大学,法国国家科学研究中心,法国国家空间研究中心);Univ. of Edinburgh(爱丁堡大学);UK Astronomy Technology Centre, STFC(英国天体技术中心,英国科学与技术设施委员会);Univ. of Durham(杜伦大学);Instituto de Astrofísica de Canarias(加那利群岛天体物理研究所);University of Oxford(牛津大学);Centre de Recherche en Astrophysique de Lyon(里昂天体物理研究中心);Centro de Astrobiología (CAB), CSIC-INTA(天体生物学中心(CAB),西班牙国家技术研究与发展总署/西班牙高等科学研究理事会);University of Michigan(密歇根大学);Institut de Planétologie et d’Astrophysique de Grenoble(格勒诺布尔行星学与天体物理学研究所)
Behind the Mask: can HARMONI@ELT detect biosignatures in the reflected light of Proxima b?
University of Oxford(牛津大学);Univ. Grenoble Alpes(格勒诺布尔阿尔卑斯大学);Université Côte d’Azur(蔚蓝海岸大学);Instituto de Física Fundamental, CSIC(西班牙国家研究委员会基础物理研究所);Aix Marseille Univ.(艾克斯-马赛大学);Massachusetts Institute of Technology(麻省理工学院);Carl Sagan Institute, Cornell University(康奈尔大学卡尔·萨根研究所);Cornell University(康奈尔大学)