arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2209.15487gr-qchep-th
收藏

MICROSCOPE任务:等效原理检验的最终结果

MICROSCOPE mission: final results of the test of the Equivalence Principle

Pierre Touboul, Gilles Métris, Manuel Rodrigues, Joel Bergé, Alain Robert, Quentin Baghi, Yves André, Judicaël Bedouet, Damien Boulanger, Stefanie Bremer, Patri… 展开作者

Pierre Touboul, Gilles Métris, Manuel Rodrigues, Joel Bergé, Alain Robert, Quentin Baghi, Yves André, Judicaël Bedouet, Damien Boulanger, Stefanie Bremer, Patrice Carle, Ratana Chhun, Bruno Christophe, Valerio Cipolla, Thibault Damour, Pascale Danto, Louis Demange, Hansjoerg Dittus, Océane Dhuicque, Pierre Fayet, Bernard Foulon, Pierre-Yves Guidotti, Daniel Hagedorn, Emilie Hardy, Phuong-Anh Huynh, Patrick Kayser, Stéphanie Lala, Claus Lämmerzahl, Vincent Lebat, Françoise Liorzou, Meike List, Frank Löffler, Isabelle Panet, Martin Pernot-Borràs, Laurent Perraud, Sandrine Pires, Benjamin Pouilloux, Pascal Prieur, Alexandre Rebray, Serge Reynaud, Benny Rievers, Hanns Selig, Laura Serron, Timothy Sumner, Nicolas Tanguy, Patrizia Torresi, Pieter Visser

AI总结:

MICROSCOPE任务通过无拖曳卫星上的差分静电加速度计比较钛铂合金与铂检验质量的加速度,最终在10^{-15}精度下未发现弱等效原理违反,将η(Ti, Pt)约束为[-1.5±2.3(stat)±1.5(syst)]×10^{-15}。

摘要:

MICROSCOPE任务旨在以10^{-15}的Eötvös比率η精度检验弱等效原理(WEP),该原理指出惯性质量与引力质量相等。其实验测试包括比较两个不同成分的并置检验质量在绕地球轨道运行时所经历的加速度,通过测量使它们保持平衡所需的静电力来实现。这是利用无拖曳卫星上的超灵敏差分静电加速度计完成的。该任务持续了两年半,累计了相当于五个月的科学自由落体数据,其中三分之二使用一对不同成分的检验质量——钛合金和铂合金——最后三分之一使用一对相同成分(铂)的参考检验质量。我们总结了数据分析,重点描述了由热不稳定性引起的系统不确定性的表征,以及对可能模拟WEP违反信号的短时事件的修正。我们发现没有违反弱等效原理,钛和铂检验质量对的Eötvös参数在1σ统计误差下被约束为η(Ti, Pt) = [-1.5 ± 2.3 (stat) ± 1.5 (syst)] × 10^{-15}。

英文摘要:

The MICROSCOPE mission was designed to test the Weak Equivalence Principle (WEP), stating the equality between the inertial and the gravitational masses, with a precision of $10^{-15}$ in terms of the Eötvös ratio $η$. Its experimental test consisted of comparing the accelerations undergone by two collocated test masses of different compositions as they orbited the Earth, by measuring the electrostatic forces required to keep them in equilibrium. This was done with ultra-sensitive differential electrostatic accelerometers onboard a drag-free satellite. The mission lasted two and a half years, cumulating five-months-worth of science free-fall data, two thirds with a pair of test masses of different compositions -- Titanium and Platinum alloys -- and the last third with a reference pair of test masses of the same composition -- Platinum. We summarize the data analysis, with an emphasis on the characterization of the systematic uncertainties due to thermal instabilities and on the correction of short-lived events which could mimic a WEP violation signal. We found no violation of the WEP, with the Eötvös parameter of the Titanium and Platinum pair constrained to $η({\rm Ti, Pt})~=~ [-1.5 \pm 2.3~{\rm (stat)} \pm 1.5~{\rm (syst)}]~\times 10^{-15}$ at $1σ$ in statistical errors.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑