arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1503.01470gr-qcastro-ph.IM
收藏

存在缺失数据与未知有色噪声的回归分析:在MICROSCOPE空间任务中的应用

Regression analysis with missing data and unknown colored noise: application to the MICROSCOPE space mission

ONERA - The French Aerospace Lab(法国航空航天实验室);Geoazur (UMR 7329), Observatoire de la Cöte d’Azur(蔚蓝海岸观测站)

Q. Baghi, G. Métris, J. Bergé, B. Christophe, P. Touboul, M. Rodrigues

AI总结:

针对有色噪声下数据间隙导致线性回归精度下降的问题,提出基于噪声自回归拟合的回归方法,在MICROSCOPE任务模拟测试中精度较普通最小二乘法提升60倍,还可提供测量不确定性的显著性检验。

摘要:

物理测量分析通常需要应对高度相关的噪声,以及由异常值、饱和事件或传输损耗导致的数据中断。我们评估了缺失数据对涉及模型化或实测时间序列拟合的线性回归分析性能的影响。我们表明,在有色噪声存在的情况下,由于噪声功率的频率泄漏,数据间隙会显著改变回归参数估计的精度。我们提出了一种回归方法,该方法可消除这种影响,即使噪声功率谱密度(PSD)并非先验已知,也能以与完整数据情况相当的精度估计目标参数。该方法基于噪声的自回归(AR)拟合,使我们能够构建接近最小方差界的近似广义最小二乘估计量。该方法可应用于任何类似的数据处理场景,我们在MICROSCOPE空间任务的模拟测量数据上对其进行了测试,该任务的目标是以$10^{-15}$的精度检验弱等效原理(WEP)。在这一特定场景中,目标信号是预计会在明确定义的频率附近出现的WEP违反信号。我们采用不同的间隙模式和PSD已知的噪声对该方法进行了测试,结果符合任务要求,与普通最小二乘法相比,不确定性降低了60倍。我们还表明,该方法可提供显著性检验,用于评估测量的不确定性。

英文摘要:

The analysis of physical measurements often copes with highly correlated noises and interruptions caused by outliers, saturation events or transmission losses. We assess the impact of missing data on the performance of linear regression analysis involving the fit of modeled or measured time series. We show that data gaps can significantly alter the precision of the regression parameter estimation in the presence of colored noise, due to the frequency leakage of the noise power. We present a regression method which cancels this effect and estimates the parameters of interest with a precision comparable to the complete data case, even if the noise power spectral density (PSD) is not known a priori. The method is based on an autoregressive (AR) fit of the noise, which allows us to build an approximate generalized least squares estimator approaching the minimal variance bound. The method, which can be applied to any similar data processing, is tested on simulated measurements of the MICROSCOPE space mission, whose goal is to test the Weak Equivalence Principle (WEP) with a precision of $10^{-15}$. In this particular context the signal of interest is the WEP violation signal expected to be found around a well defined frequency. We test our method with different gap patterns and noise of known PSD and find that the results agree with the mission requirements, decreasing the uncertainty by a factor 60 with respect to ordinary least squares methods. We show that it also provides a test of significance to assess the uncertainty of the measurement.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑