arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2209.15488gr-qcastro-ph.IMhep-th
收藏

MICROSCOPE弱等效原理检验结果

Result of the MICROSCOPE Weak Equivalence Principle test

Pierre Touboul, Gilles Métris, Manuel Rodrigues, Joel Bergé, Alain Robert, Quentin Baghi, Yves André, Judicaël Bedouet, Damien Boulanger, Stefanie Bremer, Patri… 展开作者

Pierre Touboul, Gilles Métris, Manuel Rodrigues, Joel Bergé, Alain Robert, Quentin Baghi, Yves André, Judicaël Bedouet, Damien Boulanger, Stefanie Bremer, Patrice Carle, Ratana Chhun, Bruno Christophe, Valerio Cipolla, Thibault Damour, Pascale Danto, Louis Demange, Hansjoerg Dittus, Océane Dhuicque, Pierre Fayet, Bernard Foulon, Pierre-Yves Guidotti, Daniel Hagedorn, Emilie Hardy, Phuong-Anh Huynh, Patrick Kayser, Stéphanie Lala, Claus Lämmerzahl, Vincent Lebat, Françoise Liorzou, Meike List, Frank Löffler, Isabelle Panet, Martin Pernot-Borràs, Laurent Perraud, Sandrine Pires, Benjamin Pouilloux, Pascal Prieur, Alexandre Rebray, Serge Reynaud, Benny Rievers, Hanns Selig, Laura Serron, Timothy Sumner, Nicolas Tanguy, Patrizia Torresi, Pieter Visser

AI总结:

MICROSCOPE空间任务通过比较铂钛合金检验质量的自由落体加速度,将弱等效原理检验精度提升至10⁻¹⁵量级,未发现等效原理破坏。

摘要:

致力于等效原理(EP)检验的空间任务MICROSCOPE自2016年4月25日开始运行,直至卫星于2018年10月16日退役。在本分析中,我们以Eötvös参数 $η({\rm{A, B}}) = 2 \frac{a_{\rm A}- a_{\rm B}}{a_{\rm A}+ a_{\rm B}}$ 的形式比较两个检验质量的自由落体加速度($a_{\rm A}$ 和 $a_{\rm B}$)。在由铂合金和钛合金制成的两个检验质量上,在持续13至198小时不等的19个数据段序列中,未检测到任何EP破坏,其统计误差下限小于 $10^{-14}$(针对 $η({\rm{Ti, Pt}})$)。汇总所有数据段得到 $η({\rm{Ti, Pt}}) =[-1.5\pm{}2.3{\rm (stat)}\pm{}1.5{\rm (syst)}] \times{}10^{-15}$,表明在将随机误差和系统误差按平方和方式合并时,在 $2.7\times{}10^{-15}$ 的水平上未发现EP破坏。这相对于此前由Eöt-Wash小组完成的最佳同类检验提高了近两个数量级。该限值的可靠性已通过比较两个相同成分(铂)检验质量的自由落体得到验证,其零Eötvös参数的统计不确定度为 $1.1\times{}10^{-15}$。

英文摘要:

The space mission MICROSCOPE dedicated to the test of the Equivalence Principle (EP) operated from April 25, 2016 until the deactivation of the satellite on October 16, 2018. In this analysis we compare the free-fall accelerations ($a_{\rm A}$ and $a_{\rm B}$) of two test masses in terms of the Eötvös parameter $η({\rm{A, B}}) = 2 \frac{a_{\rm A}- a_{\rm B}}{a_{\rm A}+ a_{\rm B}}$. No EP violation has been detected for two test masses, made from platinum and titanium alloys, in a sequence of 19 segments lasting from 13 to 198 hours down to the limit of the statistical error which is smaller than $10^{-14}$ for $ η({\rm{Ti, Pt}})$. Accumulating data from all segments leads to $η({\rm{Ti, Pt}}) =[-1.5\pm{}2.3{\rm (stat)}\pm{}1.5{\rm (syst)}] \times{}10^{-15}$ showing no EP violation at the level of $2.7\times{}10^{-15}$ if we combine stochastic and systematic errors quadratically. This represents an improvement of almost two orders of magnitude with respect to the previous best such test performed by the Eöt-Wash group. The reliability of this limit has been verified by comparing the free falls of two test masses of the same composition (platinum) leading to a null Eötvös parameter with a statistical uncertainty of $1.1\times{}10^{-15}$.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑