The proton boron fusion reaction, 11B(p, 3α), is investigated using MCNP6 to assess the viability for potential use in radiation therapy. The 11B(p, 3α) is theoretically desirable because it could combine the localized dose delivery protons exhibit (Bragg peak) with the creation of three high LET α particles that locally deposit energy in tumor regions. Simple simulations of a proton pencil beam incident upon a water phantom and a water phantom with an axial region also containing boron were modeled using MCNP6 in order to determine the extent of the impact boron had upon the calculated energy deposition. The MCNP simulations performed demonstrated that the proton boron fusion reaction rate at clinically relevant boron concentrations was too small in order to have any measurable impact on the absorbed dose. It was determined that there are no good evaluations of the 11B(p, 3α) reaction for use in MCNPX/6 and further work should be conducted in cross section evaluations in order to definitively evaluate the feasibility of the proton boron fusion reaction for use in radiation therapy applications.
On the (un)effectiveness of Proton Boron Capture in Proton Therapy
我们目前的计算和模拟的作用,p+ $^{11}$ B $\to$ 3 $α$反应在质子治疗。这种反应最近被认为是负责肿瘤细胞的存活概率下降,当它们被低能质子照射时。然而,在所提出的硼载体(硼帽酸钠,Na $_{2}$ B $_{12}$ H $_{11}$ SH,简称BSH)的典型浓度水平下,即小于100 ppm,计算和蒙特卡罗模拟都表明,与该反应相关的剂量比由组织内的初级质子束递送的剂量低几个数量级。这些计算对质子硼捕获在增强质子治疗的治疗效果中发挥重要作用的说法提出了一些质疑,并建议应研究其他机制,以解释观察到的生存概率下降。
Neutron relative effectiveness factors in Boron Neutron Capture Therapy: estimation of their values from the secondary charged particles and evaluation of weighted kerma factors for a standard tissue
Quantum Mechanical Analysis of Neutron Wavefunction Overlap and Nuclear Interaction Probability with Carborane Cage ($^{10}$B10) in Boron Neutron Capture Therapy
National Kaohsiung University of Science and Technology(国立高雄科技大学);National Taipei University of Technology(国立台北科技大学);The Affiliated Senior High School of National Taiwan Normal University(台湾师范大学附属高级中学)
Integrating microdosimetric in vitro RBE models for particle therapy into TOPAS MC using the MicrOdosimetry-based modeling for RBE Assessment (MONAS) tool
Mayo Clinic(梅奥诊所);China Three Gorges University(三峡大学);Guangzhou Concord Cancer Center(广州协和肿瘤中心);the University of Georgia(佐治亚大学);the University of Texas MD Anderson Cancer Center(德克萨斯大学安德森癌症中心);New York Proton Center(纽约质子中心);Memorial Sloan Kettering Cancer Center(纪念斯隆-凯特琳癌症中心)
A dosimetric and robustness analysis of Proton Arc Therapy (PAT) with Early Energy Layer and Spot Assignment (ELSA) for lung cancer versus conventional Intensity modulated therapy (IMPT)
Stopping power monitoring during proton therapy by means of prompt gamma timing: first experimental results with a homogeneous phantom
Universität zu Lübeck(吕贝克大学);INFN sezione di Torino(都灵意大利国家核物理研究所);State University of Santa Cruz(圣克鲁斯州立大学);Fondazione CNAO(CNAO基金会);Università degli Studi di Torino(都灵大学)
A new detector for the beam energy measurement in proton therapy: a feasibility study
在粒子治疗中最迫切的改进之一是用于射束质量评估和用于在照射期间监测射束能量调制的快速程序。事实上,粒子束能量的在线测量可以允许评估治疗期间的穿透范围,鼓励开发用于移动目标的新剂量输送技术。为此,提出了一种新设备的概念证明,该设备能够在几秒钟内从质子的飞行时间(ToF)测量临床质子束的能量(从60到230 MeV)。该原型由两个超快速硅探测器(UFSD)垫,具有80微米的有效厚度和3 × 3 mm 2的敏感区域,沿望远镜配置中的光束方向对齐,连接到宽带放大器并通过数字化仪读出。在Centro Nazionale di Adroterapia Oncologica(CNAO,Pavia,Italy)进行测量,使用五种不同的临床射束能量,每种能量的传感器之间有四种距离(7 - 97 cm)。为了从测量的平均ToF中获得束流能量,考虑了几种系统效应,开发了蒙特卡罗模拟来验证该方法,并采用全局拟合方法来校准系统。计算结果与审计署提供的当量水深能量值进行了对比。几百keV的偏差已经实现了所有考虑的质子束能量为67和97厘米的传感器之间的距离和几秒钟的照射是必要的收集所需的统计数据。这些初步结果表明,UFSD望远镜可以在几秒钟内达到临床应用所需的精度,因此鼓励进一步研究对本原型的改进和优化。
Combined photon-proton modeling of radiation-induced brain imaging changes supports variability in proton relative biological effectiveness and increased periventricular radiosensitivity
TUD Dresden University of Technology(德累斯顿工业大学);Helmholtz-Zentrum Dresden-Rossendorf(德累斯顿-罗斯多夫亥姆霍兹中心);TU Dortmund University(多特蒙德工业大学);National Center for Tumor Diseases (NCT)(国家肿瘤疾病中心);Institute of Neuroradiology(神经放射学研究所);German Cancer Research Center (DKFZ)(德国癌症研究中心)
Early Response Assessment in Lung Cancer Patients using Spatio-temporal CBCT Images
Indian Institute of Technology Kharagpur(印度理工学院卡拉克普尔分校);Tata Medical Center, Kolkata(塔塔医疗中心(加尔各答));Arden Cancer Centre(阿登癌症中心);Department of Computer Science and Engineering(计算机科学与工程系);Department of Radiation Oncology(放射肿瘤学系);Department of Nuclear Medicine(核医学系);Department of Medical Physics(医学物理系)