arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2205.05554eess.IVcs.CVcs.LG
收藏

深度学习系统在实际临床环境中检测可诊断糖尿病视网膜病变的性能

Performance of a deep learning system for detection of referable diabetic retinopathy in real clinical settings

Ramón y Cajal University Hospital(拉蒙·卡哈尔大学医院);Ramón y Cajal Health Research Institute (IRYCIS)(拉蒙·卡哈尔健康研究所(IRYCIS));University of Alcalá de Henares(阿尔卡拉·德·埃纳雷斯大学);Thirona(Thirona公司)

Verónica Sánchez-Gutiérrez, Paula Hernández-Martínez, Francisco J. Muñoz-Negrete, Jonne Engelberts, Allison M. Luger, Mark J. J. P. van Grinsven

摘要:

背景资料:为了确定市售深度学习系统RetCAD v.1.3.1(荷兰奈梅亨Thirona)在三级医院筛查计划的常规临床实践期间采集的彩色眼底图像数据集上自动检测可诊断糖尿病视网膜病变(DR)的能力,分析结合这种基于人工智能的技术可以减少的工作量。研究方法:该软件的评估是在2019年2月至12月期间参加我们筛查项目的3189名糖尿病患者的6325只眼睛的7195张非散瞳眼底图像数据集上进行的。该软件为每个彩色眼底图像生成DR严重程度评分,该评分被组合成眼睛水平评分。然后将该评分与由人类专家使用受试者工作特征(ROC)曲线分析设定的参考标准进行比较。结果如下:人工智能(AI)软件检测可诊断DR的ROC曲线下面积(AUC)值为0.988 [0.981:0.993]。在建议的操作点,RetCAD软件对DR的灵敏度为90.53%,特异性为97.13%。工作量减少了96%,但代价是只有6个假阴性。结论:人工智能软件正确识别了绝大多数可识别的DR病例,减少了96%需要检查的病例的工作量,同时几乎没有遗漏任何真正的病例,因此它可以用作分诊工具。

英文摘要:

Background: To determine the ability of a commercially available deep learning system, RetCAD v.1.3.1 (Thirona, Nijmegen, The Netherlands) for the automatic detection of referable diabetic retinopathy (DR) on a dataset of colour fundus images acquired during routine clinical practice in a tertiary hospital screening program, analyzing the reduction of workload that can be released incorporating this artificial intelligence-based technology. Methods: Evaluation of the software was performed on a dataset of 7195 nonmydriatic fundus images from 6325 eyes of 3189 diabetic patients attending our screening program between February to December of 2019. The software generated a DR severity score for each colour fundus image which was combined into an eye-level score. This score was then compared with a reference standard as set by a human expert using receiver operating characteristic (ROC) curve analysis. Results: The artificial intelligence (AI) software achieved an area under the ROC curve (AUC) value of 0.988 [0.981:0.993] for the detection of referable DR. At the proposed operating point, the sensitivity of the RetCAD software for DR is 90.53% and specificity is 97.13%. A workload reduction of 96% could be achieved at the cost of only 6 false negatives. Conclusions: The AI software correctly identified the vast majority of referable DR cases, with a workload reduction of 96% of the cases that would need to be checked, while missing almost no true cases, so it may therefore be used as an instrument for triage.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑