氦离子注入剂量与退火对高密度近表面NV中心层的影响

Impact of helium ion implantation dose and annealing on dense near-surface layers of NV centers

A. Berzins, H. Grube, E. Sprugis, G. Vaivars, I. Fescenko

AI总结:

本研究探究了氦离子注入剂量与退火温度对金刚石近表面NV中心层的影响,发现将注入剂量增至三倍可提升28%磁灵敏度,而1100°C额外退火仅提升6.6%,且更高剂量有望提升达70%。

摘要:

用氦离子注入金刚石已成为创建数百纳米厚近表面NV中心层的常用方法,用于高灵敏度传感和成像应用。然而,最佳注入剂量和退火温度仍存在争议。在本研究中,我们使用不同剂量的氦离子辐照初始氮浓度为100 ppm的HPHT金刚石,以创建200 nm厚的NV层。我们通过测量荧光强度、对比度、磁共振线宽以及纵向和横向弛豫时间$T_1$和$T_2$,将先前认为的最佳注入剂量$\sim10^{12}$与两倍和三倍剂量进行了比较。通过这些直接测量,我们还估算了P1和NV中心的浓度。此外,我们对比了经历三个连续退火步骤的三个金刚石样品,以量化在初始800 $^\circ$C退火之后进行1100 $^\circ$C处理的影响。通过将注入剂量增加至三倍,我们将传感器的磁灵敏度提高了$28\pm5$%。通过将结果外推至更高注入剂量,我们表明可能实现高达70%的进一步提升。同时,在1100 $^\circ$C下的额外退火步骤仅将灵敏度提高了6.6 $\pm$ 2.7%。

英文摘要:

Implantation of diamonds with helium ions becomes a common method to create hundreds-nanometers-thick near-surface layers of NV centers for high-sensitivity sensing and imaging applications. However, optimal implantation dose and annealing temperature is still a matter of discussion. In this study, we irradiated HPHT diamonds with an initial nitrogen concentration of 100 ppm using different implantation doses of helium ions to create 200-nm thick NV layers. We compare a previously considered optimal implantation dose of $\sim10^{12}$ to double and triple doses by measuring fluorescence intensity, contrast, and linewidth of magnetic resonances, as well as longitudinal and transversal relaxation times $T_1$ and $T_2$. From these direct measurements we also estimate concentrations of P1 and NV centers. In addition, we compare the three diamond samples that underwent three consequent annealing steps to quantify the impact of processing at 1100 $^{\circ}$C, which follows initial annealing at 800 $^{\circ}$C. By tripling the implantation dose we have increased the magnetic sensitivity of our sensors by $28\pm5$ %. By projecting our results to higher implantation doses we show that a further improvement of up to 70 % may be achieved. At the same time, additional annealing steps at 1100 $^{\circ}$C improve the sensitivity only by 6.6 $\pm$ 2.7 %.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑