arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2204.14050physics.med-phphysics.optics
收藏

用于检测SARS-CoV-2合成模型的偏振成像:一项概念验证研究

Polarimetric imaging for the detection of synthetic models of SARS-CoV-2: a proof of concept

Emilio Gomez-Gonzalez, Olga Muñoz, Juan Carlos Gomez-Martin, Jesus Aceituno-Castro, Beatriz Fernandez-Muñoz, Jose Manuel Navas-Garcia, Alejandro Barriga-Rivera,… 展开作者

Emilio Gomez-Gonzalez, Olga Muñoz, Juan Carlos Gomez-Martin, Jesus Aceituno-Castro, Beatriz Fernandez-Muñoz, Jose Manuel Navas-Garcia, Alejandro Barriga-Rivera, Isabel Fernandez-Lizaranzu, Francisco Javier Munoz-Gonzalez, Ruben Parrilla-Giraldez, Desiree Requena-Lancharro, Pedro Gil-Gamboa, José Luis Ramos, Cristina Rosell-Valle, Carmen Gomez-Gonzalez, Maria Martin-Lopez, Maria Isabel Relimpio-Lopez, Manuel A. Perales-Esteve, Antonio Puppo-Moreno, Francisco Jose Garcia-Cozar, Lucia Olvera-Collantes, Silvia de los Santos-Trigo, Emilia Gomez, Rosario Sanchez-Pernaute, Javier Padillo-Ruiz, Javier Marquez-Rivas

AI总结:

本研究提出利用可见光偏振成像技术检测SARS-CoV-2合成模型,通过Mueller偏振测量与逐像素图像分析,实现了对干燥液体残留物中病毒颗粒的非接触、无试剂同时检测,为病原体快速筛查提供了新方法。

摘要:

目的:开展一项概念验证研究,利用偏振成像检测严重急性呼吸综合征冠状病毒2(SARS-CoV-2)的两种合成模型。方法:制备了两种SARS-CoV-2模型,即用水疱性口炎病毒G蛋白和SARS-CoV-2特征性Spike蛋白伪型化的工程化慢病毒。样本为两种生物液体(盐溶液和人工唾液)中的制备物,设置四种浓度,并以5-μL液滴形式沉积在支撑板上。在405 nm和514 nm波长下,对87个样本进行Mueller偏振测量,以确定干燥残留物漫反射光的最大线偏振度(DLP)对应的角度。使用偏振相机在380-420 nm照明下,以接近最大DLP的角度同时对多个样本进行成像。对另外475个样本进行逐像素图像分析,包括偏振特征描述符的量化与组合。结果:405 nm和514 nm波长下的最大DLP角度(距样本表面)分别为3度和6度。在10度和15度配置下,通过偏振图像分析能够区分仅在SARS-CoV-2特征Spike蛋白上不同的相似病毒颗粒、其相应的阴性对照、液体以及样本架。结论:可见光谱中的偏振成像具有同时非接触、无试剂检测多个干燥液体残留物中病毒的潜力。仍需进一步分析包括人类样本(特别是新鲜唾液)中的真实SARS-CoV-2。意义:可见光下的偏振成像有助于SARS-CoV-2及其他病原体的快速、低成本筛查。

英文摘要:

Objective: To conduct a proof-of-concept study of the detection of two synthetic models of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using polarimetric imaging. Methods: Two SARS-CoV-2 models were prepared as engineered lentiviruses pseudotyped with the G protein of the vesicular stomatitis virus, and with the characteristic Spike protein of SARS-CoV-2. Samples were preparations in two biofluids (saline solution and artificial saliva), in four concentrations, and deposited as 5-μL droplets on a supporting plate. The angles of maximal degree of linear polarization (DLP) of light diffusely scattered from dry residues were determined using Mueller polarimetry of 87 samples at 405 nm and 514 nm. A polarimetric camera was used for simultaneous imaging of several samples under 380-420 nm illumination at angles similar to those of maximal DLP. A per-pixel image analysis included quantification and combination of polarization feature descriptors in other 475 samples. Results: The angles (from sample surface) of maximal DLP were 3 degrees for 405 nm and 6 degrees for 514 nm. Similar viral particles that differ only in the characteristic spike protein of the SARS-CoV-2, their corresponding negative controls, fluids, and the sample holder were discerned from polarimetric image analysis at 10-degree and 15-degree configurations. Conclusion: Polarimetric imaging in the visible spectrum has the potential for non-contact, reagent-free detection of viruses in multiple dry fluid residues simultaneously. Further analysis including real SARS-CoV-2 in human samples -- particularly, fresh saliva -- are required. Significance: Polarimetric imaging under visible light could contribute to fast, cost-effective screening of SARS-CoV-2 and other pathogens.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑