arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2203.15461physics.chem-phphysics.comp-ph
收藏

ELECTRODE:用于原子模拟的电化学软件包

ELECTRODE: An electrochemistry package for atomistic simulations

Ludwig J. V. Ahrens-Iwers, Mathijs Janssen, Shern R. Tee, Robert H. Meißner

摘要:

在分子动力学(MD)中,恒电位法(CPM)能够有效地模拟导电电极处的固-液界面。例如,它们已被成功地用于真实地模拟超级电容器和电池中离子液体或盐包水电解质的行为。CPM通过根据所施加的电势和(时间依赖的)局部电解质结构更新单个电极原子的电荷来对导电电极进行建模。在这里,我们提出了一个功能丰富的CPM实现,称为电极,大规模原子/分子大规模并行模拟器(LAMMPS),其中包括一个约束电荷的方法和热恒电位仪。ELECTRODE软件包还包含有限场方法、粒子-粒子-网格解算器的非周期性边界条件的多重校正以及使用非理想金属作为电极的M-Fermi模型。我们证明了这种实现的能力,为平行板双电层电容器,我们已经调查了不同的实施方法的充电时间,并发现水和离子偶极弛豫之间的一个有趣的关系。为了证明长程静电一维修正的有效性,我们估计了两个同轴碳纳米管的真空电容,并将其与无结构圆柱体进行了比较,其中存在一个解析表达式。总之,ELECTRODE软件包能够使用最先进的方法进行高效的电化学模拟,甚至可以模拟异质电极。此外,它允许更严格地揭示电极曲率如何通过一维校正影响电容。

英文摘要:

Constant potential methods (CPM) enable computationally efficient simulations of the solid-liquid interface at conducting electrodes in molecular dynamics (MD). They have been successfully used, for example, to realistically model the behavior of ionic liquids or water-in-salt electrolytes in supercapacitors and batteries. The CPM models conductive electrodes by updating charges of individual electrode atoms according to the applied electric potential and the (time-dependent) local electrolyte structure. Here we present a feature-rich CPM implementation, called ELECTRODE, for the Large-scale Atomic/Molecular Massively Parallel Simulator (LAMMPS), which includes a constrained charge method and a thermo-potentiostat. The ELECTRODE package also contains a finite-field approach, multiple corrections for non-periodic boundary conditions of the particle-particle particle-mesh solver, and a Thomas-Fermi model for using non-ideal metals as electrodes. We demonstrate the capabilities of this implementation for a parallel-plate electrical double-layer capacitor, for which we have investigated the charging times with the different implemented methods and found an interesting relationship between water and ionic dipole relaxations. To prove the validity of the one-dimensional correction for the long-range electrostatics, we estimated the vacuum capacitance of two co-axial carbon nanotubes and compared it to structureless cylinders, for which an analytical expression exists. In summary, the ELECTRODE package enables efficient electrochemical simulations using state-of-the-art methods, allowing one to simulate even heterogeneous electrodes. Moreover, it allows unveiling more rigorously how electrode curvature affects the capacitance with the one-dimensional correction.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑