Richard T. Kouzes, Alain Bonneville, Azaree Lintereur, Isar Mostafanezhad, Ryan Pang, Ben Rotter, Farjana Snigdha, Michael Tytgat, Shereen Aly, Basma ElMahdy, Y… 展开作者
Richard T. Kouzes, Alain Bonneville, Azaree Lintereur, Isar Mostafanezhad, Ryan Pang, Ben Rotter, Farjana Snigdha, Michael Tytgat, Shereen Aly, Basma ElMahdy, Yasser Assran, Ayman Mahrous
Cosmic-ray muons which impinge upon the Earth's surface can be used to image the density of geological and man-made materials located above a muon detector. The detectors used for these measurements must be capable of determining the muon rate as a function of the angle of incidence. Applications of this capability include geological carbon storage, natural gas storage, enhanced oil recovery, compressed air storage, oil and gas production, tunnel detection, and detection of hidden rooms in man-made structures such as the pyramids. For these applications the detector must be small, rugged, and have operational characteristics which enable its use in remote locations, such as low power requirements. A new muon detector design is now being constructed to make measurements on the Khafre pyramid, in Egypt, to look for unknown voids that might exist in the structure. The new detector design uses monolithic plates of scintillator with wavelength shifting fiber optic readout to obtain location information. This design will meet the operational requirements, while also providing a geometry which can be modified for different measurement conditions.
Calculations are presented to demonstrate the feasibility of Moon shadow observations for mean primary energies in the region 0.5-1.5 TeV using a muon detector operating under the Pyramid of the Sun at Teotihuacan, Mexico. Due to the small height of that monument (65 m), the experiment is capable of providing considerably high statistics, although with reduced angular accuracy for primary particle direction reconstruction. Our estimates are based on simulations of muon production and transport in the atmosphere by CORSIKA and along the body of the pyramid by GEANT4. The deflection of primaries…
The Great Pyramid or Khufu's Pyramid was built on the Giza Plateau (Egypt) during the IVth dynasty by the pharaoh Khufu (Cheops), who reigned from 2509 to 2483 BC. Despite being one of the oldest and largest monuments on Earth, there is no consensus about how it was built. To better understand its internal structure, we imaged the pyramid using muons, which are by-products of cosmic rays that are only partially absorbed by stone. The resulting cosmic-ray muon radiography allows us to visualize the known and potentially unknown voids in the pyramid in a non-invasive way. Here we report the disc…
We utilise muons from cosmic ray to explore hidden underground archaeological structures. Presented here is the design, simulation studies and first laboratory results of a compact, scintillators based, cosmic ray muon telescope for underground muon radiography.
Muon Tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons in matter is a promising technique for detecting heavily shielded high-Z radioactive materials (U, Pu) in cargo or vehicles. The technique uses the deflection of cosmic ray muons in matter to perform tomographic imaging of high-Z material inside a probed volume. A Muon Tomography Station (MTS) requires position-sensitive detectors with high spatial resolution for optimal tracking of incoming and outgoing cosmic ray muons. Micro Pattern Gaseous Detector (MPGD) technologies such as Gas Electron Multip…
The pyramids of the Giza plateau have fascinated visitors since ancient times and are the last of the Seven Wonders of the ancient world still standing. It has been half a century since Luiz Alvarez and his team used cosmic-ray muon imaging to look for hidden chambers in Khafres Pyramid. Advances in instrumentation for High-Energy Physics (HEP) allowed a new survey, ScanPyramids, to make important new discoveries at the Great Pyramid (Khufu) utilizing the same basic technique that the Alvarez team used, but now with modern instrumentation. The Exploring the Great Pyramid Mission plans to field…
In muon scattering tomography, the investigated materials are discriminated according to the scattering angle that mainly depends on the atomic number, the density, and the thickness of the medium at a given energy value. The scattering angles at different initial energies also provide the opportunity to classify the incoming muons into a number of energy groups. In this study, by employing the GEANT4 code, we show that the deflection angle exponentially decays as a function of energy, and the numerical values for the current configuration are below the detector accuracy except the initial ene…
Muon Tomography (MT) based on the measurement of multiple scattering of atmospheric cosmic ray muons traversing shipping containers is a promising candidate for identifying threatening high-Z materials. Since position-sensitive detectors with high spatial resolution should be particularly suited for tracking muons in an MT application, we propose to use compact micro-pattern gas detectors, such as Gas Electron Multipliers (GEMs), for muon tomography. We present a detailed GEANT4 simulation of a GEM-based MT station for various scenarios of threat material detection. Cosmic ray muon tracks cros…
We present results from a detailed GEANT4 simulation of a proposed Muon Tomography System that employs compact Micro Pattern Gas Detectors with high spatial resolution. A basic Point-Of-Closest-Approach algorithm is applied to reconstructed muon tracks for forming 3D tomographic images of interrogated targets. Criteria for discriminating materials by Z and discrimination power achieved by the technique for simple scenarios are discussed for different integration times. The simulation shows that Muon Tomography can clearly distinguish high-Z material from low-Z and medium-Z material. We have st…
Muon tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons is a promising technique for detecting and imaging heavily shielded high-Z nuclear materials such as enriched uranium. This technique could complement standard radiation detection portals currently deployed at international borders and ports, which are not very sensitive to heavily shielded nuclear materials. We image small targets in 3D using $2\times 2 \times 2 mm^3$ voxels with a minimal muon tomography station prototype that tracks muons with Gas Electron Multiplier (GEM) detectors read out in 2…
Muon tomography (MT), based on atmospheric cosmic rays, is a promising technique suitable for nondestructive imaging of the internal structures of mountains. This method uses the measured flux distribution after attenuation, combined with the known muon angular and energy distributions and a 3D satellite map, to perform tomographic imaging of the density distribution inside a probed volume. A muon tomography station (MTS) requires direction-sensitive detectors with a high resolution for optimal tracking of incident cosmic-ray muons. The spherical liquid scintillator detector is one of the best…
The primary objective is to enhance muon-tomographic image reconstruction capability by providing distinctive information in terms of deciding on the properties of regions or voxels within a probed volume "V" during any point of scanning: threat type, non-threat type, or not-sufficient data. An algorithm (MTclear) is being developed to ray-trace muon tracks and count how many straight tracks are passing through a voxel. If a voxel "v" has sufficient number of straight tracks (t), then "v" is a non-threat type voxel, unless there are sufficient number of scattering points (p) in "v" that will m…
Radiography with cosmic ray muon scattering has proven to be a successful method of imaging nuclear material through heavy shielding. Of particular interest is monitoring dry storage casks for diversion of plutonium contained in spent reactor fuel. Using muon tracking detectors that surround a cylindrical cask, cosmic ray muon scattering can be simultaneously measured from all azimuthal angles, giving complete tomographic coverage of the cask interior. This paper describes the first application of filtered back projection algorithms, typically used in medical imaging, to cosmic ray muon imagin…
This work reports a cost-effective, multi-parameter readout and data-acquisition system for a muon scattering tomography system based on Resistive Plate Chambers (RPCs). Initial test measurements with a prototype Resistive Plate Chamber were performed using a low-cost FPGA coupled to the NINO ASIC for the event selection and handling data. The Time over-Threshold (TOT) property of NINO ASICs has been used to achieve better position information and achieve precise tracking capability. In our test setup, we try to build an imaging setup using a single RPC and lead block, which covers some areas …
Muon tomography is a relatively new method of radiography that utilizes muons from cosmic rays and their multiple Coulomb scattering property to distinguish materials. Researchers around the world have been developing various detection systems and image reconstruction algorithms for muon tomography applications, such as nuclear reactor monitoring and cargo inspection for contraband. This paper studies the principle in image reconstruction of muon tomography. Implementation and comparison of some popular algorithms with our simulation dataset will be presented as well as some ideas of future im…
We demonstrate that muon tomography can be used to precisely measure the properties of various materials. The materials which have been considered have been extracted from an experimental blast furnace, including carbon (coke) and iron oxides, for which measurements of the linear scattering density relative to the mass density have been performed with an absolute precision of 10%. We report the procedures that are used in order to obtain such precision, and a discussion is presented to address the expected performance of the technique when applied to heavier materials. The results we obtain do…
Quality assurance and condition assessment of concrete structures is an important topic world-wide due to the ageing infrastructure and increasing traffic demands. Common topics include, but are not limited to, localisation of rebar or tendon ducts, geometrical irregularities, cracks, voids, honeycombing or other flaws. Non-destructive techniques such as ultrasound or radar have found regular, successful practical application but sometimes suffer from limited resolution and accuracy, imaging artefacts or restrictions in detecting certain features. Until the 1980s X-ray transmission was used in…
X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires high…
The muon radiography technique is part of the straight-ray scanning imaging methods and it is usually employed to produce two-dimensional images of the integrated density in the radial direction from the detector position. However, in the literature there are already some examples of muon tomographies made by combining several measurements from different observation points. The work presented in this article fits into this line of research: a tomography of a target composed of lead blocks arranged in a non-trivial geometry was carried out by means of muon absorption radiography measurements. T…
Current radiation portal monitors at sea ports and international borders that employ standard radiation detection techniques are not very sensitive to nuclear contraband that is well shielded to absorb emanating radiation. Muon Tomography (MT) based on the measurement of multiple scattering of atmospheric cosmic ray muons traversing cargo or vehicles that contain high-Z material is a promising passive interrogation technique for solving this problem. We report on the design and construction of compact Micro-Pattern Gas Detectors for a small prototype MT station. This station will employ 10 tra…
Highly energetic, cosmic-ray muons can easily penetrate a dry storage cask and yield information about the material inside it by making use of the physics of multiple Coulomb scattering. Work by others has shown this information may be used for verification of dry storage cask contents after continuity of knowledge has been lost. In our modeling and simulation approach, we use ideal planar radiation detectors to record the trajectories and momentum of both incident and exiting cosmic ray muons; this choice allows us to demonstrate the fundamental limit of the technology for a particular measur…
Muon tomographic visualization techniques try to reconstruct a 3D image as close as possible to the real localization of the objects being probed. Statistical algorithms under test for the reconstruction of muon tomographic images in the Muon Portal Project are here discussed. Autocorrelation analysis and clustering algorithms have been employed within the context of methods based on the Point Of Closest Approach (POCA) reconstruction tool. An iterative method based on the log-likelihood approach was also implemented. Relative merits of all such methods are discussed, with reference to full Ge…
In this note, we propose a novel application of geoparticle physics, namely using a muon tomograph to study ice-filled cleft systems in steep bedrock permafrost. This research could significantly improve our understanding of high alpine permafrost in general and climate-permafrost induced rockfall in particular.
Cosmic ray muon has strong penetrating power and no ionizing radiation hazards, which makes it an ideal probe for detecting special nuclear materials. In this paper, a high spatial resolution muon tomography system based on Micromegas detectors is proposed to optimize the imaging time and quality. The proposed system includes eight Micromegas detectors based on the thermal bonding technique and a scalable readout system. In addition, a multiplexing method based on position encoding is developed to reduce the number of electronics channels by order of magnitude. The spatial resolution of the pr…
Muon tomography is developing as a promising system to detect high-Z (atomic number) material for ensuring homeland security. In the present work, three kinds of spatial locations of materials which are made of aluminum, iron, lead and uranium are simulated with GEANT4 codes, which are horizontal, diagonal and vertical objects, respectively. Two statistical algorithms are used with MATLAB software to reconstruct the image of detected objects, which are the Point of Closet Approach (PoCA) and Maximum Likelihood Scattering-Expectation Maximization iterative algorithm (MLS-EM), respectively. Two …
A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80\,μ$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a scalable, inexpensive, flexible, FPGA-based system, which is demonstrated to achieve an event rate of $30\,$kHz. The tracker performance is compared with a Geant4 simulation. A scattering angle resolution compatible with $1.5\,$mrad at the $4\,$GeV average cosmic ray muon energy is demonstrated. Images of plastic, iron and lead samples are obtained using an Angl…
Imaging the inner part of large geological targets is an important issue in geosciences with various applications. Dif- ferent approaches already exist (e.g. gravimetry, electrical tomography) that give access to a wide range of informations but with identified limitations or drawbacks (e.g. intrinsic ambiguity of the inverse problem, time consuming deployment of sensors over large distances). Here we present an alternative and complementary tomography method based on the measurement of the cosmic muons flux attenuation through the geological structures. We detail the basics of this muon tomog…
The muon tomography technique, based on multiple Coulomb scattering of cosmic ray muons, has been proposed as a tool to detect the presence of high density objects inside closed volumes. In this paper a new and innovative method is presented to handle the density fluctuations (noise) of reconstructed images, a well known problem of this technique. The effectiveness of our method is evaluated using experimental data obtained with a muon tomography prototype located at the Legnaro National Laboratories (LNL) of the Istituto Nazionale di Fisica Nucleare (INFN). The results reported in this paper,…
Cosmic ray muon, as they pass through a material, undergoes Multiple Coulomb Scattering (MCS). The analysis of muon scattering angle in a material provides us with an opportunity to study the characteristics of material and its internal 3D structure as the scattering angle depends on the atomic number, the density of the material, and the thickness of the medium at a given energy. We have used the GEANT4 toolkit to study the scattering angle and utilize this information to identify the material. We have analyzed the density dependent $\&$ density independent scattering angle and observed vario…
High-energy muons generated from cosmic-ray particle showers have been shown to exhibit properties ideal for imaging the interior of large structures. This paper explores the possibility of using a single portable muon detector in conjunction with image reconstruction methods used in nuclear medicine to reconstruct a 3D image of the interior of critical infrastructure such as the Zero Energy Deuterium (ZED-2) research reactor at Canadian Nuclear Laboratories' Chalk River site. The ZED-2 reactor core and muon detector arrangement are modeled in GEANT4 and Monte Carlo measurements of the resulta…
Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons are increasingly being exploited for the non-destructive assay of shielded containers in a wide range of applications. One such application is the characterisation of legacy nuclear waste materials stored within industrial containers. The design, assembly and performance of a prototype muon tomography system developed for this purpose are detailed in this work. This muon tracker comprises four detection modules, each containing orthogonal layers of Saint-Gobain BCF-10 2mm-pitch plastic scintillating fibres. Identif…
Cosmic Ray Muon Radiography utilizes highly-penetrating cosmic ray muons to image the density profile of an object of interest. Here we report on the first trial to use a portable field-deployable cosmic ray tracking system in order to image the whole overburden of a UK railway tunnel with short duration scans (c. 30 minutes). A unknown overburden void was identified and, post-trial, confirmed by railway authorities. These experiments demonstrate the identification of hidden construction shafts with high levels of statistical significance as density anomalies within the data.
Muon tomography is a generic imaging method using the differential absorption of cosmic muons by matter. The measured contrast in the muons flux reflects the matter density contrast as it does in conventional medical imaging. The applications to volcanology present may advantadges induced by the features of the target itself: limited access to dangerous zones, impossible use of standard boreholes information, harsh environmental conditions etc. The Diaphane project is one of the largest and leading collaboration in the field and the present article summarizes recent results collected on the Le…
Nuclear materials accountability and nonproliferation are among the critical tasks to be addressed for the advancement of nuclear energy in the United States. Monitoring spent nuclear fuel is important to continue reliable stewardship of SNF storage. Cosmic ray muons have been acknowledged a promising radiographic tool for monitoring SNF due to their highly penetrative nature and high energy. Cosmic ray muons are more suitable and have been used for imaging large and dense objects. Despite their potential in various applications, the wide application of cosmic ray muons is limited by the natur…
This work presents a generalized muon trajectory estimation (GMTE) algorithm to estimate the path of a muon in either uniform or nonuniform media. The use of cosmic ray muons in nuclear nonproliferation and safeguards verification applications has recently gained attention due to the nonintrusive and passive nature of the inspection, penetrating capabilities, as well as recent advances in detectors that measure position and direction of the individual muons before and after traversing the imaged object. However, muon image reconstruction techniques are limited in resolution due to low muon flu…
The use of muon scattering tomography for the non-invasive characterisation of nuclear waste is well established. We report here on the application of a combination of feature discriminators and multivariate analysis techniques to locate and identify materials in nuclear waste drums. After successful training and optimisation of the algorithms they are then tested on a range of material configurations to assess the system's performance and limitations. The system is able to correctly identify uranium, iron and lead objects on a ~few \text{cm} scale. The system's sensitivity to small uranium ob…
Muons interact with matter via two major interaction mechanisms: ionization and radioactive process, and multiple Coulomb scattering leading to energy loss and trajectory deflection, respectively. For a monoenergetic muon beam crossing an object, the scattering angle follows a Gaussian distribution with a zero mean value and a variance that depends on the atomic number of the material object it traversed. Thus, the measured scattering angle may be used to reconstruct the geometrical and material information of the contents inside the dry storage cask. In traditional X-ray computed tomography, …
Cosmic ray muon tomography is a novel technology to detect high-Z material. A prototype of TUMUTY with 73.6 cm x 73.6 cm large scale position sensitive MRPC detectors has been developed and is introduced in this paper. Three test kits have been tested and image is reconstructed using MAP algorithm. The reconstruction results show that the prototype is working well and the objects with complex structure and small size (20 mm) can be imaged on it, while the high-Z material is distinguishable from the low-Z one. This prototype provides a good platform for our further studies of the physical chara…
Among numerous applications of muon tomography, deployment in civil structures has caught attraction of many recently. In this work, the appropriateness of muon scattering tomography to detect defects in concrete structures has been studied numerically. A few basic concrete structures that are frequently used in civil construction, have been considered as test cases. A simulation has been performed on Geant4 platform where an imaging setup built with several gaseous ionization detectors, having a specific spatial resolution for tracking the muons, have been modeled. The images of the test case…
Full Characterization of a Mock Nuclear Waste Barrel with Muon Tomography using Micromegas Detectors
CEA/Irfu, Université Paris-Saclay(法国原子能委员会/核研究与物理技术研究所,巴黎萨克雷大学);Centro de Astropartículas y Física de Altas Energías (CAPA), Universidad de Zaragoza(高能天体粒子中心,萨拉戈萨大学)
A feasibility demonstration of three-dimensional (3D) muon tomography was performed for infrastructure equivalent targets using the proposed portable muography detector. For the target, we used two sets of lead blocks placed at different heights. The detector consists of two muon position-sensitive detectors, made of plastic scintillating fibers (PSFs) and multi-pixel photon counters (MPPCs) with an angular resolution of 8 msr. The maximum likelihood-expectation maximization (ML-EM) method was used for the 3D imaging reconstruction of the muography simulation and measurement. For both simulati…
Experimental Demonstration of Soft-Tissue Muon Scattering Tomography
CERN, European Organization for Nuclear Research(欧洲核子研究中心);ETH Zürich(苏黎世联邦理工学院);Instituto de Física Corpuscular (CSIC/Universitat de València)(粒子物理研究所(西班牙科学理事会/瓦伦西亚大学))
The scattering angle due to the target volume can be split into two interior angles in the tomographic setups based on the muon scattering, and we call this property as the triangular correlation where the sum of these two interior angles is equal to the scattering angle. In this study, we apply this triangular correlation for a multi-block material configuration that consist of concrete, stainless steel, and uranium. By changing the order of this material set, we employ the GEANT4 simulations and we show that the triangular correlation is valid in the multi-block material setups, thereby prov…
This paper explores the use of cosmic ray muons to image the contents of shielded containers and detect high-Z special nuclear materials inside them. Cosmic ray muons are a naturally occurring form of radiation, are highly penetrating and exhibit large scattering angles on high Z materials. Specifically, we investigated how radiographic and tomographic techniques can be effective for non-invasive nuclear waste characterization and for nuclear material accountancy of spent fuel inside dry storage containers. We show that the tracking of individual muons, as they enter and exit a structure, can …
Cosmic ray muon computed tomography (μCT) is a new imaging modality with unique characteristics that could be particularly important for diverse applications including nuclear nonproliferation, spent nuclear fuel monitoring, cargo scanning, and volcano imaging. The strong scattering dependence of muons on atomic number Z in combination with high penetration range could offer a significant advantage over existing techniques when dense, shielded containers must be imaged. However, μCT reconstruction using conventional filtered back-projection is limited due to the overly simple assumptions that …